Defining homogeneous units to optimize the monitoring and management of groundwater is a key challenge for organizations responsible for the protection of water for human consumption. However, the number of groundwater bodies (GWBs) is too large for targeted monitoring and recommendations. This study, carried out in the Provence-Alpes-Côte d’Azur region of France, is based on the intersection of two databases, one grouping together the physicochemical and bacteriological analyses of water and the other delimiting the boundaries of groundwater bodies. The extracted dataset contains 8627 measurements from 1143 observation points distributed over 63 GWB. Data conditioning through logarithmic transformation, dimensional reduction through principal component analysis, and hierarchical classification allows the grouping of GWBs into 11 homogeneous clusters. The fractions of unexplained variance (FUV) and ANOVA R2 were calculated to assess the performance of the method at each scale. For example, for the total dissolved load (TDS) parameter, the temporal variance was quantified at 0.36 and the clustering causes a loss of information with an R2 going from 0.63 to 0.4 from the scale of the sampling point to that of the GWB cluster. The results show that the logarithmic transformation reduces the effect of outliers and improves the quality of the GWB clustering. The groups of GWBs are homogeneous and clearly distinguishable from each other. The results can be used to define specific management and protection strategies for each group. The study also highlights the need to take into account the temporal variability of groundwater quality when implementing monitoring and management programs.
In France, the data resulting from monitoring water intended for human consumption are integrated into a national database called SISE-Eaux, a useful and relevant tool for studying the quality of raw and distributed water. A previous study carried out on all the data from the Provence-Alpes-Côte d’Azur (PACA) region in south-eastern France (1061 sampling points, 5295 analyses and 15 parameters) revealed that the dilution of the information in a heterogeneous environment constitutes an obstacle to the analysis of ongoing processes that are sources of variability. In this article, cross-referencing this information with the compartmentalization into groundwater bodies (MESO) provides a hydrogeological constraint on the dataset that can help to better define more homogeneous subsets and improve the interpretation. The approach involves three steps: (1) A principal component analysis conducted on the whole dataset aimed at eliminating information redundancy; (2) an unsupervised grouping of groundwater bodies having similar sources of variability; (3) a principal component analysis carried out within the main groups and sub-groups identified, aiming to define and prioritize the sources of variability and the associated processes. The results supported by discriminant analysis and machine learning show that the grouping of MESO is the best-suited scale to study ongoing processes due to greater homogeneity. One of the eight main groups identified in PACA, corresponding to the accompanying aquifers of the main rivers, is analyzed by way of illustration. Water–rock interactions, redox processes and their effects on the release of metals, arsenic and fecal contamination along different pathways were specifically identified with varying impacts according to the subgroups. We discussed both the significance of the principal components and the mean values of the bacteriological parameters, which provide information on the causes and on the state of contamination, respectively. Based on the results from two different groups of MESO, some guidelines in terms of a strategy for resource quality monitoring are proposed.
In order to facilitate the monitoring of groundwater quality in France, the groundwater bodies (GWB) in the Provence-Alpes-Côte d’Azur region have been grouped into 11 homogeneous clusters on the basis of their physico-chemical and bacteriological characteristics. This study aims to test the legitimacy of this grouping by predicting whether water samples belong to a given sampling point, GWB or group of GWBs. To this end, 8673 observations and 18 parameters were extracted from the Size-Eaux database, and this dataset was processed using discriminant analysis and various machine learning algorithms. The results indicate an accuracy of 67% using linear discriminant analysis and 69 to 83% using ML algorithms, while quadratic discriminant analysis underperforms in comparison, yielding a less accurate prediction of 59%. The importance of each parameter in the prediction was assessed using an approach combining recursive feature elimination (RFE) techniques and random forest feature importance (RFFI). Major ions show high spatial range and play the main role in discrimination, while trace elements and bacteriological parameters of high local and/or temporal variability only play a minor role. The disparity of the results according to the characteristics of the GWB groups (geography, altitude, lithology, etc.) is discussed. Validating the grouping of GWBs will enable monitoring and surveillance strategies to be redirected on the basis of fewer, homogeneous hydrogeological units, in order to optimize sustainable management of the resource by the health agencies.
The delineation of pollution plumes generated by household waste landfills is not easy, particularly in the case of discontinuous or intricately extending water tables, such as those developed in a fractured crystalline bedrock context. In Ouagadougou (Burkina Faso), there are many uncontrolled landfills throughout the urban area. The water table, generally located between 3 and 10 m deep, is likely to be contaminated by the leachate from these landfills. More than 1000 measurements of spontaneous potential (self-potential), referenced by GPS, have been carried out on a landfill and its immediate surroundings to the south of the urban area. The geostatistical processing by analysis of variograms and correlograms highlights an adapted prospecting technique and reliable cartography. The response seems to be mainly due to the electrochemical component with hot spots within the landfill and a plume heading towards the North-East. The distribution of the spontaneous potential seems to be controlled, not by the topography of the site, but by the fracturing of the mother rock of dominant direction 15° N, and by the mother rock/saprolite contact. Thus, the plume does not flow to the market gardening just below the landfill but rather to a residential area where monitoring of the quality of the borehole water is required.