Gerardo Nigro

Gerardo Nigro

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2020 in European Heart Journal
Verified
Journal Article
Open access
PDF file
MBMichele Brignole
Michele Brignole
VRVincenzo Russo
Vincenzo Russo
FAFrancesco Arabia
Francesco Arabia
MOMario Oliveira
Mario Oliveira
APAlonso Pedrote
Alonso Pedrote
FIfor the BioSync CLS trial Investigators
for the BioSync CLS trial Investigators
The benefit of cardiac pacing in patients with severe recurrent reflex syncope and asystole induced by tilt testing has not been established. The usefulness of tilt-table test to select candidates for cardiac pacing is controversial. We randomly assigned patients aged 40 years or older who had at least two episodes of unpredictable severe reflex syncope during the last year and a tilt-induced syncope with an asystolic pause longer than 3 s, to receive either an active (pacing ON; 63 patients) or an inactive (pacing OFF; 64 patients) dual-chamber pacemaker with closed loop stimulation (CLS). The primary endpoint was the time to first recurrence of syncope. Patients and independent outcome assessors were blinded to the assigned treatment. After a median follow-up of 11.2 months, syncope occurred in significantly fewer patients in the pacing group than in the control group [10 (16%) vs. 34 (53%); hazard ratio, 0.23; P = 0.00005]. The estimated syncope recurrence rate at 1 year was 19% (pacing) and 53% (control) and at 2 years, 22% (pacing) and 68% (control). A combined endpoint of syncope or presyncope occurred in significantly fewer patients in the pacing group [23 (37%) vs. 40 (63%); hazard ratio, 0.44; P = 0.002]. Minor device-related adverse events were reported in five patients (4%). In patients aged 40 years or older, affected by severe recurrent reflex syncope and tilt-induced asystole, dual-chamber pacemaker with CLS is highly effective in reducing the recurrences of syncope. Our findings support the inclusion of tilt testing as a useful method to select candidates for cardiac pacing. ClinicalTrials.gov identifier NCT02324920, Eudamed number CIV-05-013546.

2 June 2023 in European Heart Journal
Verified
Journal Article
Closed access
PDF file
Vincenzo RussoVincenzo Russo
Vincenzo Russo
EPErika Parente
Erika Parente
MTMarco Tomaino
Marco Tomaino
ACAngelo Comune
Angelo Comune
ASAntonella Sabatini
Antonella Sabatini
MBMichele Brignole
Michele Brignole
The traditional nitroglycerin (NTG) head-up tilt test (HUTT) is time-consuming and the test duration is a barrier to widespread utilization in clinical practice. It was hypothesized that a short-duration protocol is not inferior to the traditional protocol regarding the positivity rate and has a similar distribution of hemodynamic response. Patients undergoing HUTT were randomized 1:1 to a 10 min passive phase plus a 10 min 0.3 mg NTG if the passive phase was negative (Fast) or to a 20 min passive phase plus a 15 min 0.3 mg NTG if the passive phase was negative (Traditional). A sample size of 277 patients for each group achieved 80% power to detect an expected difference of 0% with a non-inferiority margin of -10% using a one-sided t-test and assuming a significant level alpha of 0.025. A total of 554 consecutive patients (mean age 46.6 ± 19.3 years, 47.6% males) undergoing HUTT for suspected vasovagal syncope were randomly assigned to the Fast (n = 277) or Traditional (n = 277) protocol. A positive response was defined as the induction of syncope in presence of hypotension/bradycardia, and was observed in 167 (60.3%) patients with Fast and in 162 (58.5%) patients with the Traditional protocol. There was a trend of lesser vasodepressor response (14.8% Fast vs. 20.6% Traditional) which was significant during the passive phase (P = 0.01). The diagnostic value of the Fast HUTT protocol is similar to that of the Traditional protocol and therefore the Fast protocol can be used instead of the Traditional protocol. Fast Italian protocol: positivity rate and type of haemodynamic responses compare to traditional HUTT protocol.

29 August 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
PPPietro Palmisano
Pietro Palmisano
DFDomenico Facchin
Domenico Facchin
MZMatteo Ziacchi
Matteo Ziacchi
GNGerardo Nigro
Gerardo Nigro
ANAntonino Nicosia
Antonino Nicosia
SISaverio Iacopino
Saverio Iacopino
The safety and efficacy of leadless intracardiac-permanent pacemaker (L-PM) have been demonstrated in multiple clinical trials, but data on comparisons with conventional transvenous-permanent pacemaker (T-PM) collected in a consecutive, prospective fashion are limited. The aim of this analysis was to compare the rate and the nature of device-related complications between patients undergoing L-PM vs. T-PM implantation. Prospective, multicentre, observational project enrolling consecutive patients who underwent L-PM or T-PM implantation. The rate and nature of device-related complications were analysed and compared between the two groups. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 2669 (n = 665 L-PM) patients were included and followed for a median of 39 months, L-PM patients were on average older and had more co-morbidities. The risk of device-related complications at 12 months was significantly lower in the L-PM group (0.5% vs. 1.9%, P = 0.009). Propensity matching yielded 442 matched pairs. In the matched cohort, L-PM patients trended toward having a lower risk of overall device-related complications (P = 0.129), had a similar risk of early complications (≤30 days) (P = 1.000), and had a significantly lower risk of late complications (>30 days) (P = 0.031). All complications observed in L-PM group were early. Most (75.0%) of complications observed in T-PM group were lead- or pocket-related. In this analysis, the risk of device-related complications associated with L-PM implantation tended to be lower than that of T-PM. Specifically, the risk of early complications was similar in two types of PMs, while the risk of late complications was significantly lower for L-PM than T-PM.

13 April 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Vincenzo RussoVincenzo Russo
Vincenzo Russo
RBRoberta Bottino
Roberta Bottino
ARAnna Rago
Anna Rago
APAndrea Antonio Papa
Andrea Antonio Papa
BLBiagio Liccardo
Biagio Liccardo
GNGerardo Nigro
Gerardo Nigro
Sacubitril/valsartan therapy reduces sudden cardiac death (SCD) among patients with reduced ejection fraction (HFrEF) when compared to guidelines recommended doses of enalapril, however the mechanism is still not clear. There are few, contrasting results about the effect of sacubitril/valsartan on arrhythmias in the clinical context of dilated cardiomyopathy (DCM) and there are no clinical data about its effect on measured implantable cardioverter defibrillator (ICD) electrical parameters, such as atrial/ventricular electrograms sensing and pacing threshold. We conducted a 12 month follow-up observational study in 167 ischemic and nonischemic DCM patients (mean age 68.1 ± 11.6 years; 85% male), with dual-chamber ICD on sacubitril/valsartan treatment, to evaluate the incidence of device detected tachyarrhythmia events, both atrial and ventricular, and the change in measured ICD electrical parameters. We collected data on clinical, electrocardiographic and echocardiographic parameters to find a possible electro-mechanical correlation within results. Our results show that DCM patients with reduced ejection fraction and ICD on sacubitril/valsartan treatment experienced a reduction in both atrial and ventricular arrhythmias incidence and an improvement in ICD electrical atrial parameters. The findings might be explained by the electro-mechanical cardiac reverse remodeling induced by sacubitril/valsartan therapy.

Verified
Journal Article
Open access
PDF file
Vincenzo RussoVincenzo Russo
Vincenzo Russo
RBRoberta Bottino
Roberta Bottino
ACAndreina Carbone
Andreina Carbone
ARAnna Rago
Anna Rago
APAndrea Antonio Papa
Andrea Antonio Papa
GNGerardo Nigro
Gerardo Nigro
A highly pathogenic human coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has been recently recognized in Wuhan, China, as the cause of the coronavirus disease 2019 (COVID-19) outbreak which has spread rapidly from China to other countries in the world, causing a pandemic with alarming morbidity and mortality. The emerging epidemiological data about COVID-19 patients suggest an association between cardiovascular diseases (CVD) and SARS-CoV-2 infection, in term of clinical features at hospital admission and prognosis for disease severity. The aim of our review is to describe the cardiological features of COVID-19 patients at admission, the acute cardiac presentation, the clinical outcome for patients with underlying CVD and the pharmacological implications for disease management.

16 February 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
Giovanni BottoGiovanni Botto
Giovanni Botto
MZMatteo Ziacchi
Matteo Ziacchi
GNGerardo Nigro
Gerardo Nigro
ADAntonio D'Onofrio
Antonio D'Onofrio
ARAntonio Dello Russo
Antonio Dello Russo
LCLuca Checchi
Luca Checchi
A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17–0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30–0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50–1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.