Ivan Curkovic

Dr. Ivan Curkovic

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Ivan LukačevićIvan Lukačević
Ivan Lukačević
ICIvan Curkovic
Ivan Curkovic
ARAndrea Rajić
Andrea Rajić
MBMarko Bartolac
Marko Bartolac
In the last few decades, the application of lightweight cold-formed composite steel–concrete structural systems has constantly been increasing within the field of structural engineering. This can be explained by efficient material usage, particularly noticeable when using cold-formed built-up sections and the innovative types of shear connections. This paper summarises an overview of the development of the cold-formed composite steel–concrete floor systems. Additionally, it provides the background, planned activities, and preliminary results of the current LWT-FLOOR project, which is ongoing at the University of Zagreb, Faculty of Civil Engineering, Croatia. The proposed structural system is formed of built-up cold-formed steel beams and cast-in-place concrete slabs that are interconnected using an innovative type of shear connection. Preliminary analytical and numerical results on the system bending capacity are presented. Obtained results are mutually comparable. The resistance of the fixed beam solution is governed by the resistance of the steel beam, while pinned beam solution is governed by the degree of shear connection without the influence of the increased number of spot welds in the steel beam.

22 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ARAndrea Rajić
Andrea Rajić
Ivan LukačevićIvan Lukačević
Ivan Lukačević
Davor SkejicDavor Skejic
Davor Skejic
ICIvan Curkovic
Ivan Curkovic
This paper investigates the bending resistance of an innovative lightweight composite floor system, LWT-FLOOR. The system consists of built-up cold-formed steel elements that are spot-welded and connected to the concrete slab using demountable shear connectors. As the system under investigation is new, the existing standards do not provide guidelines for calculating its bending resistance. This paper gives an overview of different analytical approaches and a comparison of calculated results using bending capacities from the numerical parametric study. Within the numerical parametric study, the influence of the height of the steel beam, the type and degree of shear connection, the connection between the steel elements, and the thickness of the corrugated web used for the bending capacity are investigated. Numerical results for the full shear connections resulted in lower bending capacities than the analytically calculated plastic bending resistances. However, numerically obtained bending capacities for partial shear connections were found to exceed the calculated characteristic non-linear bending resistances and bending resistances for partial shear connections. The obtained results will comprise the basis for further experimental tests, which will support the search for an optimal analytical approach for the bending resistance of the proposed composite system.

17 April 2025 in Thin-Walled Structures
Verified
Journal Article
Closed access
VŽVlaho Žuvelek
Vlaho Žuvelek
ICIvan Curkovic
Ivan Curkovic
ILIvan Lukačević
Ivan Lukačević
ARAndrea Rajić
Andrea Rajić

24 January 2024 in Buildings
Verified
Journal Article
Open access
PDF file
VŽVlaho Žuvelek
Vlaho Žuvelek
ICIvan Curkovic
Ivan Curkovic
Davor SkejicDavor Skejic
Davor Skejic
Ivan LukačevićIvan Lukačević
Ivan Lukačević
It is known that steel–concrete composite systems are very efficient. However, such steel–concrete composite systems can be optimised using cold-formed steel elements and innovative shear connections. In other words, by considering demountability and reusability, the negative impact of the built environment on the whole ecosystem can ultimately be reduced. This paper, therefore, presents a numerical study of an innovative solution for a composite floor system consisting of built-up cold-formed sections and concrete slabs. Through parametric numerical analysis, parameters such as the diameter and quality of bolts, the concrete class, the type of concrete slab, and the steel quality of sections and bolts were varied. The numerical analysis results show that the system with a solid concrete slab had a higher shear resistance and ductility than the system with a concrete slab made with profiled sheeting and showed different failure modes. The presented results form the basis for push-out tests for the proposed shear connection types.

1 March 2021 in Journal of the Croatian Association of Civil Engineers
Verified
Journal Article
Open access
PDF file
Davor SkejicDavor Skejic
Davor Skejic
DODomagoj Orehovec
Domagoj Orehovec
ICIvan Curkovic
Ivan Curkovic
Prefabricated aluminium halls are usually temporary structures with multiple uses. Their biggest advantage is low weight resulting in lower transport costs and allowing for quick assembly. Today, there is a growing demand for aluminium halls to become permanent structures, and therefore, in meeting the requirements of EN 199x norm series, it is necessary to optimize the calculation aspect of conventional structural systems with reinforced bolted joints. An overview of the most common structural systems, typical aluminium profiles and joints with steel reinforcements, as well as a common approach for design and assembly, is presented in the paper.

4 September 2022
Verified
Conference Paper
Closed access
VŽVlaho Žuvelek
Vlaho Žuvelek
ICIvan Curkovic
Ivan Curkovic
Composite systems made by combining cold-formed steel (CFS) and concrete can produce excellent properties compared to traditional solutions. One such innovative solution is the subject of this paper which consists of built-up CFS with corrugated web, connected by spot-welds and concrete slab with innovative type of shear connection. This paper presents numerical investigation of two types of shear connections suitable for the proposed composite solution. One type of shear connection is completed using bolts which provide a direct shear connection between the flange of CFS girder and the concrete slab. The second type of shear connection was completed using composite dowel rib connector. The results of FE simulations indicate that solution with bolts ensures higher stiffness of the shear connection, but in turn reduces its ductility.