In the last few decades, the application of lightweight cold-formed composite steel–concrete structural systems has constantly been increasing within the field of structural engineering. This can be explained by efficient material usage, particularly noticeable when using cold-formed built-up sections and the innovative types of shear connections. This paper summarises an overview of the development of the cold-formed composite steel–concrete floor systems. Additionally, it provides the background, planned activities, and preliminary results of the current LWT-FLOOR project, which is ongoing at the University of Zagreb, Faculty of Civil Engineering, Croatia. The proposed structural system is formed of built-up cold-formed steel beams and cast-in-place concrete slabs that are interconnected using an innovative type of shear connection. Preliminary analytical and numerical results on the system bending capacity are presented. Obtained results are mutually comparable. The resistance of the fixed beam solution is governed by the resistance of the steel beam, while pinned beam solution is governed by the degree of shear connection without the influence of the increased number of spot welds in the steel beam.
This paper investigates the bending resistance of an innovative lightweight composite floor system, LWT-FLOOR. The system consists of built-up cold-formed steel elements that are spot-welded and connected to the concrete slab using demountable shear connectors. As the system under investigation is new, the existing standards do not provide guidelines for calculating its bending resistance. This paper gives an overview of different analytical approaches and a comparison of calculated results using bending capacities from the numerical parametric study. Within the numerical parametric study, the influence of the height of the steel beam, the type and degree of shear connection, the connection between the steel elements, and the thickness of the corrugated web used for the bending capacity are investigated. Numerical results for the full shear connections resulted in lower bending capacities than the analytically calculated plastic bending resistances. However, numerically obtained bending capacities for partial shear connections were found to exceed the calculated characteristic non-linear bending resistances and bending resistances for partial shear connections. The obtained results will comprise the basis for further experimental tests, which will support the search for an optimal analytical approach for the bending resistance of the proposed composite system.
Steel and composite shear wall systems are used for vertical stabilisation of buildings and have been widely investigated in recent decades. Such systems provide excellent shear strength and ductility while allowing material savings due to optimal material usage and an increase in construction speed. A double-skin cold-formed steel shear wall filled with concrete is an innovative composite shear wall that is composed of cold-formed corrugated steel sheets and intermediate fasteners filled with concrete which is in turn bounded by a steel frame. Steel sheets are connected onto a concrete core with the help of intermediate fasteners behaving as shear connectors forming a sandwich Steel–Concrete–Steel panel. Compared to reinforced concrete shear walls, this type of wall has enhanced strength and ductility due to steel confinement while allowing for a reduction in construction time. The numerical simulation of double-skin cold-formed steel shear walls filled with concrete has been studied in this paper. The numerical parametric simulations are conducted in ABAQUS/CAE, where the influence of steel sheet thicknesses, concrete strength and the arrangement and diameter of the shear connectors were analysed. The wall shear capacities for all parameters were compared and the results provide suggestions for future investigations.
Cold-formed steel composite floors are lightweight systems whose application increased in the last few decades. According to the design guidelines, the frequency of floor systems should be more than 4 Hz while in the case of light steel floors, the natural frequency of the system should be in the high frequency range above 8 Hz. The main focus of this paper is to investigate the vibration performance of an innovative lightweight composite floor system called LWT-FLOOR. The LWT-FLOOR system is composed of spot-welded built-up cold-formed steel elements that are connected to a lightweight concrete slab. Based on laboratory tests material properties of all components of the system are obtained and the finite element model of cold-formed steel concrete composite floor is created to investigate its vibration behaviour. Numerical analyses were conducted in Abaqus/CAE, where after mesh density verification, the influence of the degree of shear connection, spot weld density, concrete type and class, steel channels cross-section thickness and the arrangement and diameter of the shear connector were analysed. The results show that the flexural rigidity of the system and vibration characteristics can be improved by changing those parameters, especially by changing steel channel cross-section characteristics and support conditions from nominally pinned to nominally rigid.
Application of composite structural systems have many benefits, such as a prefabrication and long span capability, but also the optimal utilisation of structural steel and concrete which is given particulary by implementation of cold-formed steel (CFS) elements. This paper presents numerical parametric analysis on an innovative solution of a composite floor structure system consisting of built-up CFS elements and slabs. Type of connection between CFS elements and the degree of shear connection had the most significant impact on LWT-FLOOR system behaviour, while the corrugated web thickness, spot weld density and considered steel beam heights had less influence on the analysed composite system behaviour.
The Innovative Lightweight Cold-Formed Steel–Concrete Composite Floor System (LWT-FLOOR) addresses key challenges faced by the construction industry related to the efficiency, adaptability, and life-cycle usability of structural elements. Within this context, the present study investigated the behaviour of demountable bolted shear connections in a composite system combining built-up cold-formed steel (CFS) girders and concrete slabs. An experimental programme comprising 18 push-out tests was conducted on two composite configurations: built-up back-to-back CFS sections and built-up sections incorporating a corrugated web. The influence of key parameters, including the bolt diameter, CFS thickness, steel grade, and connector spacing, was evaluated. The results show that increasing the bolt diameter enhanced the shear resistance and initial stiffness while reducing ductility, whereas reducing the CFS thickness led to a moderate decrease in resistance accompanied by a pronounced increase in ductility. The incorporation of a corrugated web increased the ultimate shear resistance by approximately 30–40%. The existing analytical models from current standards were found to be inadequate; however, the introduction of a spacing-dependent correction factor into the prEN 1994-1-1 model significantly improved the prediction accuracy, reducing the coefficient of variation from 16% to 4.36%. The findings provide a quantitative basis for improving the design of demountable shear connections in lightweight composite CFS-concrete systems.