Paracetamol is an analgesic-antipyretic drug and Ibuprofen is a non-steroidal anti-inflammatory drug. They are co-formulated as tablets to improve analgesia, to simplify prescribing and to improve patient compliance. Three accurate, simple and sensitive spectrophotometric methods were developed for the simultaneous determination of Paracetamol and Ibuprofen in their co-formulated dosage form. The first method was the ratio difference, which was based on the measurement of the difference in absorbance between the two wavelengths (210.6 and 216.4 nm) for Ibuprofen and (236.0 and 248.0 nm) for Paracetamol. The second method was constant center method which depends on using the constant found in the ratio spectra. The third method was the mean centering of ratio spectra which measured the manipulated values at 240 nm and 237 nm for Ibuprofen and Paracetamol, respectively. Beer’s law was obeyed in the concentration range of 2–50 μg/mL for Ibuprofen and 2–20 μg/mL for Paracetamol. The recovery % of the accuracy of both methods ranged from 99.64 to 100.56%. Factors affecting the resolution of the spectra were studied and optimized. The three methods are validated according to ICH guidelines and could be applied for the pharmaceutical preparation.
Two inexpensive and simple methods for synthesis of carbon nanodots were applied and compared to each other, namely a hydrothermal and microwave-assisted method. The synthesized carbon nanodots were characterized using transmission electron microscopy (TEM), ultraviolet-visible (UV-Vis), photoluminescence (PL), Fourier transform-infrared spectroscopy (FTIR), and X-ray diffraction (XRD). The synthesized microwave carbon nanodots had smaller particle size and were thus chosen for better electrochemical performance. Therefore, they were used for our modification process. The proposed electrodes performance characteristics were evaluated according to the IUPAC guidelines, showing linear response in the concentration range 10−6–10−2, 10−7–10−2, and 10−8–10−2 M of tobramycin with a Nernstian slope of 52.60, 58.34, and 57.32 mV/decade for the bare, silver nanoparticle and carbon nanodots modified carbon paste electrodes, respectively. This developed potentiometric method was used for quantification of tobramycin in its co-formulated dosage form and spiked human plasma with good recovery percentages and without interference of the co-formulated drug loteprednol etabonate and excipients.
Considering the green chemistry perspective and improving the environmental impact of quality control labs; two direct techniques with less hazardous solvents, less waste production and less energy consumption were developed for simultaneous analysis of Aspirin and Metoclopramide in bulk powder and pharmaceutical formulation. The ratio between the two drugs in their co-formulated preparation is very challenging; (90: 1, Aspirin: Metoclopramide). The first technique is spectrophotometry using simple mathematical operations; ratio difference and derivative ratio–zero crossing. The second technique is high-performance thin-layer chromatography (HPTLC) -densitometry which used a mobile phase consisting of cyclo-hexane: methanol: methylene chloride in a ratio of (1:4:1, v/v/v). The greenest solvents which give acceptable resolution were chosen. Following the International Conference on Harmonization (ICH) guidelines, the methods were found to be accurate, precise, and selective. Those methods were statistically compared to the reported spectrophotometric method and the results proved that there is no significant difference in accuracy and precision. Furthermore, the developed methods were assessed using the Analytical Eco-scale, Green Analytical Procedure Index (GAPI) and the Analytical Greenness calculator (AGREE), which gave a full image about their greenness profile. The spectrophotometry was found to be an excellent green technique compared to HPTLC with was considered an acceptable green one. The developed HPTLC-densitometric method was used for the first time for the analysis of this binary mixture. The two proposed spectrophotometric methos have advantages over the published methods as they used easy manipulation steps and are applied on the market pharmaceutical formulation. Owing to the advantages of the developed techniques; being green, do not require expensive sophisticated equipment or large volume of solvents; they could be used for routine analysis in quality control aspects.
This work describes the development, optimization and validation of a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for the simultaneous analysis of co-administered ranitidine (RAN) and metronidazole (MET) in plasma of healthy human volunteers. A simple protein precipitation procedure using 1 mL acetonitrile was applied to extract both drugs and metoclopramide as an internal standard (IS) from plasma. The chromatographic separation was achieved on a C18 column with isocratic elution of the mobile phase consisting of acetonitrile and 0.1% formic acid (90 : 10, v/v) at a flow rate of 0.35 mL min−1. The positive ionization mode was used for detecting the ions, by observing the pairs of transition m/z 314.82 < 176.06 for RAN, m/z 172.03 < 127.95 for MET and m/z 299.86 < 277.10 for IS. The linearity range was from 5–600 ng mL−1 for RAN and 2–40 μg mL−1 for MET. The method was found to be sensitive and accurate with good simple extraction recovery and matrix effect, according to FDA guidelines for bioanalytical methods. The developed method could be applied for further bioavailability studies that could be useful in therapeutic drug monitoring.
1 April 2019 in JPC – Journal of Planar Chromatography – Modern TLC
A rapid validated thin-layer chromatography (TLC)‒densitometric method has been developed for the simultaneous determination of 3 co-formulated drugs used for common cold and cough treatment. The studied drugs are paracetamol, pseudoephedrine, and chlorpheniramine maleate. The separation was achieved using silica gel 60 F254 plates and the developing system of methanol‒ toluene‒acetic acid (44:16:1, v/v). Densitometry scanning was performed at 254 nm. The method was validated as per the International Conference on Harmonization (ICH) guidelines and was successfully applied for the analysis of pharmaceutical preparation containing the cited ternary mixture without interference from excipients. There is no previously published TLC–densitometric method for the determination of the previously mentioned ternary mixture. The suggested method is rapid and of low cost, so it can be used for quality control analysis.