Titanium chalcogenides are valuable candidates for visible light photocatalysis at high efficiency levels. TiS2/TiO2 core shell heterostructures are able to increase this efficiency by an effective quenching of the exiton recombination.
Two inexpensive and simple methods for synthesis of carbon nanodots were applied and compared to each other, namely a hydrothermal and microwave-assisted method. The synthesized carbon nanodots were characterized using transmission electron microscopy (TEM), ultraviolet-visible (UV-Vis), photoluminescence (PL), Fourier transform-infrared spectroscopy (FTIR), and X-ray diffraction (XRD). The synthesized microwave carbon nanodots had smaller particle size and were thus chosen for better electrochemical performance. Therefore, they were used for our modification process. The proposed electrodes performance characteristics were evaluated according to the IUPAC guidelines, showing linear response in the concentration range 10−6–10−2, 10−7–10−2, and 10−8–10−2 M of tobramycin with a Nernstian slope of 52.60, 58.34, and 57.32 mV/decade for the bare, silver nanoparticle and carbon nanodots modified carbon paste electrodes, respectively. This developed potentiometric method was used for quantification of tobramycin in its co-formulated dosage form and spiked human plasma with good recovery percentages and without interference of the co-formulated drug loteprednol etabonate and excipients.
12 November 2020 in The Journal of Physical Chemistry C
Recently, neoadjuvant treatment has turned out to be a feasible alternative for individuals suffering from locally advanced breast cancer. The neoadjuvant therapy is a type of chemotherapy that is given either before or after surgeries to diminish a tumor and minimize the likelihood of recurrence. This article demonstrates the development of a unique bioanalytical validated sensitive method by means of an ultra high performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) approach for the concurrent estimation of neoadjuvant treatments including 5-Fluorouracil, Doxorubicin, and Capecitabine in rat plasma. Samples were prepared using the fine minor QuEChERS process and analyzed using a Shimadzu-C18 column via an isocratic separation. Acetonitrile:water in the ratio of (30:70) (both containing 0.1 percent formic acid v/v) was the mobile phase employed at a flow rate of 0.20 mL/min. At concentrations of 50.00–500.00 ng/mL for 5-Fluorouracil, 25.00–500.00 ng/mL for Doxorubicin, and 5.00–100.00 ng/mL for Capecitabine, the procedure was shown to be linear. The limit of detection (LOD) was assessed in ng/mL and varied from 1.33 to 13.50. Relative standard deviations for precision were below 2.47 percent over the whole concentration range. For all analytes, the average recovery rate varied from 73.79 to 116.98 percent. A preliminary pharmacokinetic study was successfully performed in real rats to evaluate the procedure efficiency.
Monitoring fungicide residues in orange fruits is vital, as fungicides for orange cultivation are increasingly used to prevent yield loss. At the same time, increasing restrictions are added by regulatory organizations. For facile on-site monitoring of the fungicide carbendazim (MBC), five ion-selective potentiometric sensors are proposed and compared. The first two sensors were prepared with a precipitation-based technique using molybdate (sensor 1) and tetraphenylborate (TPB) (sensor 2), respectively. Furthermore, two ionophore-based sensors were prepared using β-cyclodextrin as ionophore together with TPB (sensor 3) and tetrakis(4-chlorophenyl)borate (TpClPB) (sensor 4) as ion-exchanger. Further incorporation of multi-walled carbon nanotubes (MWCNTs) between the graphite rod and the sensing membrane of sensor 4 (sensor 5) further improved the stability and significantly lowered the limit of detection (LOD). Their performance was evaluated according to IUPAC recommendations, revealing linear response in the concentration range 1 × 10−4–1 × 10−2 M, 1 × 10−5–1 × 10−2 M, 1 × 10−5–1 × 10−3 M, 1 × 10−6–1 × 10−3 M, and 1 × 10−7–1 × 10−3 M with a Nernstian slope of 54.56, 55.48, 56.00, 56.85, and 57.34 mV/decade, respectively. The LOD values for the five sensors were found to be 7.92 × 10−5, 9.98 × 10−6, 9.72 × 10−6, 9.61 × 10−7, and 9.57 × 10−8 M, respectively. The developed potentiometric sensors were successfully applied to determine the residue and degradation rate of MBC in orange samples. After the researched fungicide was applied to the orange trees, the preharvest interval (PHI) could be calculated based on the MBC degradation kinetics determined in the tested orange samples.
16 October 2026 in Journal of Pharmaceutical Sciences
Solid lipid nanoparticles (SLNPs) may be used as carriers for lipophilic drugs but also offer potential for the formulation of hydrophilic biomacromolecules via surface adsorption. Regarding the latter, specific surface area and particle anisometry are key parameters, yet quantitative methods to assess them for non-spherical particles remain limited. In this study, a hydrodynamic approach based on Perrin's theory for oblate ellipsoids was applied to approximate particle anisometry from dynamic light scattering data. Using this approach, the influence of matrix lipid type, particle size, emulsifier type, and emulsifier concentration on the shape of SLNPs was systematically investigated. Along the triglyceride series trilaurin to tristearin, particle anisometry increased with chain length, consistent with the formation of thinner, more platelet-like particles. Smaller SLNPs exhibited lower anisometry than larger particles. Interfacial effects were pronounced: post-modification with different emulsifiers resulted in marked differences in hydrodynamically approximated anisometry, with sucrose monolaurate-treated systems showing the highest and poloxamer 407-treated systems the lowest apparent anisometry. Increasing the concentration of poloxamer 188 reduced anisometry, whereas increasing the concentration of sucrose monolaurate increased it. Electron microscopic imaging qualitatively confirmed the calculated trends in particle shape. Overall, the presented method provides a practical screening tool for comparing relative changes in SLNP anisometry. It also enables the assessment of formulation-dependent differences in particle shape characteristics, which may be highly relevant for optimizing the adsorption of hydrophilic macromolecules to nanoparticle surfaces.