Weiwei Xu

Weiwei Xu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Applied Optics
Verified
Journal Article
Closed access
WXWeiwei Xu
Weiwei Xu
中国中国科学院安徽光学精密机械研究所,安徽合肥230031
中国科学院安徽光学精密机械研究所,安徽合肥230031
ZLZhang Liming
Zhang Liming
LXLi Xin
Li Xin
SXSi Xiaolong
Si Xiaolong
中国中国科学院通用光学定标与表征技术重点实验室,安徽合肥230031
中国科学院通用光学定标与表征技术重点实验室,安徽合肥230031

24 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
RLRuijin Li
Ruijin Li
LZLiming Zhang
Liming Zhang
XWXianhua Wang
Xianhua Wang
WXWeiwei Xu
Weiwei Xu
XLXin Li
Xin Li
CHChunhui Hu
Chunhui Hu
To realize high-precision and high-frequency unattended site calibration and detection of satellites, automatic direction adjustment must be implemented in mirror arrays. This paper proposes a high-precision automatic calibration model based on a novel point light source tracking system for mirror arrays. A camera automatically observes the solar vector, and an observation equation coupling the image space and local coordinate systems is established. High-precision calibration of the system is realized through geometric error calculation of multipoint observation data. Moreover, model error analysis and solar tracking verification experiments are conducted. The standard deviations of the pitch angle and azimuth angle errors are 0.0176° and 0.0305°, respectively. The root mean square errors of the image centroid contrast are 2.0995 and 0.8689 pixels along the x- and y-axes, respectively. The corresponding pixel angular resolution errors are 0.0377° and 0.0144°, and the comprehensive angle resolution error is 0.0403°. The calculated model values are consistent with the measured data, validating the model. The proposed point light source tracking system can satisfy the requirements of high-resolution, high-precision, high-frequency on-orbit satellite radiometric calibration and modulation transfer function detection.

5 August 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
QWQiang Wang
Qiang Wang
WXWeiwei Xu
Weiwei Xu
XSXiaolong Si
Xiaolong Si
SBShiwei Bao
Shiwei Bao
LZLiming Zhang
Liming Zhang
JLJianjun Li
Jianjun Li
Factors such as the optical point spread function (PSF), intrapixel sensitivity (IPS), and interpixel crosstalk of an imaging system can cause the response to point sources to vary with position, directly affecting the absolute radiometric calibration accuracy of the remote sensor. This paper investigates an absolute radiometric calibration method based on a multilevel point source array and quantitatively evaluates the differences in response stability between a single point source and a point source array as a function of position. The method improves the stability and accuracy of point source response acquisition through subpixel sampling and averaging, and obtains the calibration coefficients of the imaging system by linear regression on multilevel data, thereby achieving wide-dynamic-range calibration based on the point source array. The test results indicate that the stability of the point source response using a 6 × 6 array is better than 0.21%, while the stability of the calibration coefficient is better than 0.3%. The relative difference between the point source calibration coefficient and the results calculated using conventional extended source calibration methods is within 1.5%, thereby validating the effectiveness of the point source array calibration method. Further optimization based on on-orbit application requirements indicates that a point source array ranging from 2 × 2 to 3 × 3 can reduce response fluctuations in the imaging system by a factor of 6 to 10; point source arrays within this range offer high engineering feasibility while maintaining calibration accuracy. Following an uncertainty analysis, the laboratory measurement uncertainty of the calibration method using a multilevel point source array was found to be 3.2%; when the method was applied to on-orbit absolute radiometric calibration, the estimated uncertainty was approximately 3.9%. The multilevel point source array effectively enhances calibration accuracy while ensuring response stability and accuracy, thereby providing technical support for point-source-based on-orbit absolute radiometric calibration.

1 January 2025 in Journal of Applied Optics
Verified
Journal Article
Open access
PDF file
QKQian Kun
Qian Kun
WXWeiwei Xu
Weiwei Xu
SXSi Xiaolong
Si Xiaolong
HWHuang Wenxin
Huang Wenxin
ZLZhang Liming
Zhang Liming
YBYang Baoyun
Yang Baoyun

调制传递函数是红外遥感卫星像质评价的核心参数,但其在轨检测面临靶标温差稳定性不足与数据处理复杂两大挑战。提出一种基于三线靶标与温阶靶标协同的在轨调制传递函数(modulation transfer function,MTF)直接检测方法,通过靶标设计与模糊PID(proportional-integral-derivative)温控算法,实现靶标温度均匀性(<0.5 ℃)、稳定性(±0.6 ℃)与重复性(>99%)的良好表现。基于傅里叶光学理论与辐射传输模型,结合“物方-像方调制度分离”计算原理,从遥感影像中直接提取奈奎斯特频率处MTF值,避免了传统方法中大气因素、数值微分以及参数拟合误差等对MTF检测的影响,为高分辨率红外卫星定量化应用提供了高精度技术支撑。