We propose a space benchmark sensor with onboard SI (Système International) traceability by means of quantum optical radiometry. Correlated photon pairs generated by spontaneous parametric down-conversion (SPDC) in nonlinear crystals are used to calibrate the absolute responsivity of a solar observing radiometer. The calibration is systematic, insensitive to degradation and independent of external radiometric standards. Solar spectral irradiance at 380–2500 nm is traceable to the photon rate and Planck’s constant with an expected uncertainty of about 0.35%. The principle of SPDC calibration and a prototype design of the solar radiometer are introduced. The uncertainty budget is analyzed in consideration of errors arising from calibration and observation modes.
In this paper, the spatial properties of correlated photon in collinear phase-matching in the process of spontaneous parametric down conversion (SPDC) are researched. Based on the study of the phase-matching angle, non-collinear angle, and correlated photon wavelength, a theoretical model of non-collinear angular variation is derived, which can be used to estimate and predict the width of the correlated photon ring. The experimental measurement is carried out with CMOS camera, and the measurement results are consistent with the theoretical simulation results, which verifies the rationality of theoretical reasoning. Meanwhile, the change of the correlated photon divergence angle outside the crystal is studied, the closer the wavelength is to the degenerate, the smaller the measurement value of the divergence angle, which is agreement with the theoretical simulation. The results of the study play a reference role in the evaluation of the spatial properties of correlated photon and lay a foundation for the measurement of the correlated photon number rate and the calibration of a photodetector.
The accurate measurement of high-resolution solar spectral irradiance (SSI) and its variations at the top of the atmosphere is crucial for solar physics, the Earth’s climate, and the in-orbit calibration of optical satellites. However, existing space-based solar spectral irradiance instruments achieve high-precision SSI measurements at the cost of spectral resolution, which falls short of meeting the requirements for identifying fine solar spectral features. Therefore, this paper proposes a new method for reconstructing high-resolution solar spectral irradiance based on a residual channel attention network. This method considers the stability of SSI spectral features and employs residual channel attention blocks to enhance the expression ability of key features, achieving the high-accuracy reconstruction of spectral features. Additionally, to address the issue of excessively large output features from the residual channel attention blocks, a scaling coefficient adjustment network block is introduced to achieve the high-accuracy reconstruction of spectral absolute values. Finally, the proposed method is validated using the measured SSI dataset from SCIAMACHY on Envisat-1 and the simulated dataset from TSIS-1 SIM. The validation results show that, compared to existing scaling coefficient adjustment algorithms, the proposed method achieves single-spectrum super-resolution reconstruction without relying on external data, with a Mean Absolute Percentage Error (MAPE) of 0.0302% for the reconstructed spectra based on the dataset. The proposed method achieves higher-resolution reconstruction results while ensuring the accuracy of SSI.
We introduce a novel calibration optical path of the cryogenic radiometer, which can avoid the repeated dismounting measurement and eliminate the negative influence of Brewster window effect on calibration result. The novel calibration optical path is used to calibrate the absolute spectral responsivity of the standard transfer detector at 633 nm, the results of which are compared with the ones of the previous structure. It is shown that comparing the previous results to the structure optimization, the measurement uncertainty of laser power reduces by a factor of 2, the measurement uncertainty on the absolute spectral responsivity of the transfer detector decreases by 15%, and the consistence of the calibration on absolute spectral responsivity is 4.0 \times 10-3. The experiment result proves that the novel calibration optical path of cryogenic radiometer can effectively reduce the calibration uncertainty against standard detector and improve the accuracy of calibration.