Empirical analysis from several recent studies has shown mixed results on the 'frictionless market' hypothesis, claimed by many, about Internet retailing compared to conventional channels. This study takes a different approach to deal with this apparent 'paradox' of online retailing. We observe that the emergence of online retailing threatens the business of conventional retailers. In response to this challenge, some conventional retailers have entered the online market to directly compete with those specialized 'DotCom' sellers. We hypothesize that the pricing behaviour of these online branches of conventional retailers would be part of their parent companies' integrated strategies of doing business in both the online and offline markets. Focusing on a homogenous product (CDs), we compared the pricing behaviour of six major online branches of traditional CD retailers with six top specialized Internet retailers. We find that prices by the pure Internet players are generally lower than prices by the hybrids online. Further, price changes by both types are few but adjustment magnitudes are large, indicating that menu cost is not as negligible as many claim for the online markets. Evidence shows that price dispersion is lower among the DotComs than among the hybrids online for the popular titles but significantly higher for the random titles. We conclude that the online CD market is far from perfectly competitive or frictionless. Market power and offline pricing behaviour continue to influence the online competition.
22 October 2018 in IEEE Transactions on Biomedical Engineering
In this paper, a set of novel whole-body gradient coils is designed for cylindrical magnetic resonance imaging (MRI) systems. For the sake of high coil efficiency, the design scheme focuses on the imaging volume occupied by the patient, discounting the large space under the patient bed that is unused during imaging. To further improve the coil performance, the coils are designed on an unconventional, hybrid cylindrical-planar structure, where the primary coils are arranged on a chord-truncated cylindrical former while the shielding coils remain on the cylindrical assemblies. In this new coil configuration, the primary layers make the best possible use of the space closest to the imaging volume, whilst the shielding layers are positioned the furthest from the primary layers; thus the best gradient field/current ratio can be obtained for the body coil configuration. Using a boundary element method (BEM), a full gradient set was designed to demonstrate the effectiveness of the proposed scheme. Compared with conventional designs, the new approach provides significantly improved coil performance. For the three gradient axes, the inductance was reduced by 25%~50%, the resistance was decreased by 19%~39%, and the minimum wire distance was increased by 5.2%~45.5%. In terms of shielding effect, the maximum stray fields of the X- and Y- gradient coils are reduced by 79.5% and 38.7%, respectively. It is concluded that the new design is capable of producing high-quality gradients with less eddy currents and thermal heating concerns, being suitable for MRI applications demanding high gradient performance.
24 January 2019 in IEEE Transactions on Biomedical Engineering
In magnetic resonance imaging (MRI), system imperfections and eddy currents can cause gradient field deviation (GFD), leading to various image distortions such as increased noise, ghosting artefacts and geometric deformation. These distortions can degrade the clinical value of MR images. Generally, non-Cartesian image sequences, such as radial sampling, produce larger gradient deviations than Cartesian sampling, as a result of stronger eddy current-induced gradient delays and phase errors. In this work, we developed a GFD encoding method to reduce image noise and artefacts for radial MRI. In the proposed method, a hybrid norm (combination of L2-L1 norms) optimisation problem was formed, that incorporated a wavelet sub-band adaptive regularisation mechanism. The new approach seeks a regularised solution not only offering corrected images with reduced artefacts and geometric deformation, but also good preservation of anatomical structural details. The new method was evaluated with simulation and experiment at 9.4T MRI. The results demonstrated that the proposed method can provide over 50% noise reduction and 15% artefact reduction compared with the traditional regridding method, suggesting substantially reduced GFD-induced distortions and improved image quality.