Colin Gilmore

Dr. Colin Gilmore

Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2020 in IEEE Antennas and Propagation Magazine
Verified
Journal Article
Closed access
JLJoe LoVetri
Joe LoVetri
MAMohammad Asefi Asefi
Mohammad Asefi Asefi
Colin GilmoreColin Gilmore
Colin Gilmore
IJIan Jeffrey
Ian Jeffrey

24 July 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
BMBen Martin
Ben Martin
Keeley EdwardsKeeley Edwards
Keeley Edwards
IJIan Jeffrey
Ian Jeffrey
Colin GilmoreColin Gilmore
Colin Gilmore
Microwave (or Electromagnetic) Imaging systems seek a quantitative reconstruction of the target permittivity. Such systems require calibration of the raw S -parameter data. This calibration is especially difficult in some systems where known targets cannot be introduced (e.g. grain bin imaging). Herein we present a machine-learning based method of calibrating such systems that does not require measuring a known target inside of the imaging chamber. Using a Cycle-Generative Adversarial Network (Cycle-GAN) machine-learning network, we show that we can calibrate data from a 2-D scalar Microwave Imaging (MWI) system and successfully reconstruct targets. Cycle-GAN makes use of two sets of data: experimental and synthetic. Unlike traditional calibration there is no need for the experimental data to be labeled i.e. the calibration targets do not need to be ‘known’. Results show that with an experimental calibration set of roughly 150 targets the Cycle-GAN approach provides comparable results to known-target calibration for the class of targets we used in this 2D near-field MWI systems..

27 October 2021 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Open access
EAElvis Asihene
Elvis Asihene
DDDurell Desmond
Durell Desmond
MHMadison L. Harasyn
Madison L. Harasyn
DLDavid Landry
David Landry
CVCathrin Veenaas
Cathrin Veenaas
DIDustin Isleifson
Dustin Isleifson
Oil spills in the Arctic are becoming more likely as shipping traffic increases in response to climate-related sea ice loss. To improve oil spill detection capability, we used a controlled mesocosm to analyze the multipolarized C-band backscatter response of oil in newly formed sea ice (NI). Artificial sea ice was grown in two cylindrical tubs at the Sea-ice Environmental Research Facility, University of Manitoba. The sea ice physical characteristics, including surface roughness, thickness, temperature, and salinity, were measured before and after oil injection below the ice sheet. Time-series C-band radar backscatter measurements detected the differences in the sea ice evolution and oil migration to the sea ice surface in the oil-contaminated tub, which was compared to uncontaminated ice in a control tub. Immediately prior to the presence of oil on the ice surface, the copolarized backscatter is increased by 13-dB local maximum, while the cross-polarized backscatter is decreased by 9-dB. Ice physical properties suggest that the local backscatter maximum and minimum, which occurred immediately before oil migrated onto the surface, were related to a combination of brine and oil upward migration. The findings of this work provide a baseline data interpretation for oil detection in the Arctic Ocean using current and future C-band multipolarization radar satellites.

5 September 2019 in IEEE Access
Verified
Journal Article
Open access
Colin GilmoreColin Gilmore
Colin Gilmore
IJIan Jeffrey
Ian Jeffrey
MAMohammad Asefi
Mohammad Asefi
NGNicholas T. Geddert
Nicholas T. Geddert
KBKevin G. Brown
Kevin G. Brown
JLJoe Lovetri
Joe Lovetri
Electromagnetic inversion systems require that the experimental data be calibrated to the computational inversion model being used. In addition, accurate prior information provided to the inversion algorithm leads to higher-quality images. For some applications of inversion, such as stored grain imaging or geophysical inversion, known (calibration) targets cannot be easily introduced into the imaging region and the ability to determine prior information can be limited. In an attempt to solve the problem of calibrating data from such field-inversion systems, we introduce a work flow where: (1) a simple parametric physical model of the scattering background is obtained via a phaseless (magnitude only data) inversion algorithm that works on phase-corrupted, uncalibrated total-field measurements, and (2) we then use this simple physical model to generate calibration and prior information for subsequent full-data (magnitude and phase) inversion. Using an example of in-bin stored grain imaging, the inverted parameters are the grain angle of repose, grain height, and the average bulk permittivity of the grain. Using uncalibrated total-field data, we show that the proposed work flow obtains the overall structure of the grain in a bin despite the use of this raw data. We then show that the simple physical model can be used as both a calibration data set as well as the prior information about the grain target in a full-data (magnitude and phase) inversion. The use of this phaseless algorithm means we are able to remotely calibrate imaging systems, and obtain critical prior information about the imaging region without introducing a calibration target or physically measuring the imaging region in other ways.

13 March 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Keeley EdwardsKeeley Edwards
Keeley Edwards
VKVahab Khoshdel
Vahab Khoshdel
MAMohammad Asefi
Mohammad Asefi
JLJoe LoVetri
Joe LoVetri
Colin GilmoreColin Gilmore
Colin Gilmore
IJIan Jeffrey
Ian Jeffrey
A two-stage workflow for detecting and monitoring tumors in the human breast with an inverse scattering-based technique is presented. Stage 1 involves a phaseless bulk-parameter inference neural network that recovers the geometry and permittivity of the breast fibroglandular region. The bulk parameters are used for calibration and as prior information for Stage 2, a full phase contrast source inversion of the measurement data, to detect regions of high relative complex-valued permittivity in the breast based on an assumed known overall tissue geometry. We demonstrate the ability of the workflow to recover the geometry and bulk permittivity of the different sized fibroglandular regions, and to detect and localize tumors of various sizes and locations within the breast model. Preliminary results show promise for a synthetically trained Stage 1 network to be applied to experimental data and provide quality prior information in practical imaging situations.

1 November 2023 in IEEE Open Journal of Antennas and Propagation
Verified
Journal Article
Open access
SCSeth Cathers
Seth Cathers
JLJoe LoVetri
Joe LoVetri
IJIan Jeffrey
Ian Jeffrey
Colin GilmoreColin Gilmore
Colin Gilmore
Calibration is essential in electromagnetic imaging for converting the raw measurements to a usable form for the imaging algorithm. The complexity of the calibration technique can range between a simple comparison of the raw measurement to those of a known calibration target, to a comprehensive simulation of the entire imaging chamber. This work introduces a novel approach to calibration that models the antennas and field propagation as 2-port networks (rather than scalars or a comprehensive model), for which common network theory and de-embedding techniques can be applied. The accuracy of the proposed 2-port method is experimentally tested against the scalar calibration technique on a 2D imaging system. The use of both metallic and dielectric calibration objects is tested, and the inversion performance is compared for the calibration techniques. For the experimental system tested herein, the use of a 2-port model for each transmitter/receive antenna pair moderately improved both calibration accuracy and image quality compared to a simple scalar calibration coefficient, for the cost of measuring a minimum of 2 known calibration targets.