Manabu Watamane

Dr. Manabu Watamane

Tokyo Denki University

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2016 in Earth, Planets and Space
Verified
Journal Article
Open access
PDF file
Manabu WatamaneManabu Watamane
Manabu Watamane
Rajesh Bahadur ThapaRajesh Bahadur Thapa
Rajesh Bahadur Thapa
TOTsuneo Ohsumi
Tsuneo Ohsumi
HFHiroyuki Fujiwara
Hiroyuki Fujiwara
CYChinatsu Yonezawa
Chinatsu Yonezawa
SSSinichi Suzuki
Sinichi Suzuki
The interferometric SAR coherence-change technique with coherence filter and polarization (HH and HV) has been used to detect the parts of buildings damaged by the 2015 Gorkha Earthquake. A survey of the building damage was conducted in every house to evaluate the detection accuracy in the Khokana and Sankhu urban areas in the Kathmandu Valley of Nepal. The damaged parts of the urban area were adequately detected using coherence-change (∆γ) values obtained before the earthquake (γ pre) and during the inter-seismic stage of the earthquake (γ int). The use of a coherence filter effectively increased overall accuracy by ~2.1 to 7.0 % with HH polarization. The incorporation of HV polarization marginally increased the accuracy (~0.9 to 1.2 %). It was confirmed that road damage due to liquefaction was also observed using the interferometric SAR coherence-change detection technique. The classification accuracy was lower (27.1–35.1 %) for areas that were damaged. However, higher accuracy (97.8–99.2 %) was achieved for areas that were damage-free, in ∆γ obtained from HH and HV polarization with a coherence filter. This helped to identify the damaged urban areas (using this technique) immediately after occurrence of an earthquake event.

29 March 2018 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Open access
Manabu WatamaneManabu Watamane
Manabu Watamane
CKChristian Koyama
Christian Koyama
MHMasato Hayashi
Masato Hayashi
INIzumi Nagatani
Izumi Nagatani
MSMasanobu Shimada
Masanobu Shimada
Polarimetric characteristics of early-stage deforestation areas were examined with L-band synthetic aperture radar (SAR) to develop a forest early warning system. Time series of PALSAR-2/ScanSAR data and Landsat data were used to examine the differences in detection timing of deforestation in the most active deforestation sites in Peru and Brazil. The γ 0 HH value increased by 0.8 dB on average for areas undergoing early-stages of deforestation, in which felled trees were left on the ground. The detection timing was almost the same as that of using the optical sensor. On the other hand, the γ 0 HV value does not show significant γ 0 change at this early-stage of deforestation. The γ 0 HV value started to decrease 1-1.5 months after the deforestation was detected by Landsat. The γ 0 HV value decreased by 1.5-1.6 dB, 4-5 months after the deforestation. To understand the radar backscattering mechanism at the early-stage deforestation sites, field experiments were carried out 2-16 days after the PALSAR-2/fully-polarimetric observations. The early-stage deforestation sites revealed 1.1-2.5 dB and 2.9-4.0 dB increases for σ 0 HH and σ 0 surface, respectively. This can be explained by the direct (single bounce) scattering from felled trees left on the ground. The sites in which felled trees were removed and the surfaces were flattened showed 5.2-5.3 dB and 5.3-5.5 dB decreases for σ 0 HV and σ 0 volume, respectively. This can be explained by the lower sensitivity of the HV polarization to both the branches remaining on the ground and the surface roughness, along with its increased sensitivity to the forest biomass. We conclude that an increase in L-band γ 0 HH is a good indicator for detecting early-stage deforestation sites, where felled trees are left on the ground, while γ 0 HV may be useful for detecting later-stage deforestation sites.

13 December 2017 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Closed access
Ryo NatsuakiRyo Natsuaki
Ryo Natsuaki
TMTakeshi Motohka
Takeshi Motohka
Manabu WatamaneManabu Watamane
Manabu Watamane
Masanobu  ShimadaMasanobu Shimada
Masanobu Shimada
SSShinichi Suzuki
Shinichi Suzuki
In this paper, the authors propose a novel radio frequency interference (RFI) detection and removal method for a synthetic aperture radar (SAR). The proposed method is exclusively sensitive to a pulse-like signal that is temporally transmitted in wide bandwidth. The bandwidth of the RFI is supposed to be similar or wider than the bandwidth of the SAR, while traditional RFI detectors assume that it is narrower and thus it can be removed in the range-frequency and azimuth-time domain using a bandpass filter. On the other hand, the proposed method employs a local autocorrelation-based detection scheme in the range-time and azimuth-frequency domain. The proposed method assumes the existence of another type of RFI, namely, intermittently transmitted wideband (ITWB) RFI. Once ITWB RFI superimposes on the SAR image, its short-pulse duration/wide bandwidth hinders the detection in the range-frequency and azimuth-time domain. Conversely, in the range-time and azimuth-frequency domain, ITWB RFI can be detected easily because its Doppler frequency profile does not fit with backscattered signals from the ground. In this paper, a basic methodology and the experimental results are presented.

9 June 2017 in Remote Sensing
Verified
Journal Article
Open access
PDF file
CKChristian Koyama
Christian Koyama
HLHai Liu
Hai Liu
Manabu WatamaneManabu Watamane
Manabu Watamane
KTKazunori Takahashi
Kazunori Takahashi
MSMotoyuki Sato
Motoyuki Sato
MSMotoyuki Sato
Motoyuki Sato
At radar frequencies below 2 GHz, the mismatch between the 5 to 15 cm sensing depth of classical time domain reflectometry (TDR) probe soil moisture measurements and the radar penetration depth can easily lead to unreliable in situ data. Accurate quantitative measurements of soil water contents at various depths by classical methods are cumbersome and usually highly invasive. We propose an improved method for the estimation of vertical soil moisture profiles from multi-offset ground penetrating radar (GPR) data. A semi-automated data acquisition technique allows for very fast and robust measurements in the field. Advanced common mid-point (CMP) processing is applied to obtain quantitative estimates of the permittivity and depth of the reflecting soil layers. The method is validated against TDR measurements using data acquired in different environments. Depth and soil moisture contents of the reflecting layers were estimated with root mean square errors (RMSE) on the order of 5 cm and 1.9 Vol.-%, respectively. Application of the proposed technique for the validation of synthetic aperture radar (SAR) soil moisture estimates is demonstrated based on a case study using airborne L-band data and ground-based P-band data. For the L-band case we found good agreement between the near-surface GPR estimates and extended integral equation model (I2EM) based SAR retrievals, comparable to those obtained by TDR. At the P-band, the GPR based method significantly outperformed the TDR method when using soil moisture estimates at depths below 30 cm.

3 May 2019 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Closed access
MOMasato Ohki
Masato Ohki
Takeo TadonoTakeo Tadono
Takeo Tadono
TITakuya Itoh
Takuya Itoh
KIKeiko Ishii
Keiko Ishii
TYTsutomu Yamanokuchi
Tsutomu Yamanokuchi
Masanobu  ShimadaMasanobu Shimada
Masanobu Shimada
Rapid detection of flood areas in all weather conditions is needed for monitoring and mitigating flood disasters. In this paper, we investigated flood area detection using L-band synthetic aperture radar data acquired by the Phased-Array-type L-band Synthetic Aperture Radar-2 (PALSAR-2) aboard the Advanced Land Observing Satellite-2 during the 2015 heavy rainfall disaster in Kanto and Tohoku areas of Japan. This paper comprehensively compared various observation conditions of PALSAR-2, such as incidence angles, resolutions, and polarizations. We successfully detected open-water flood and built-up area flood by thresholding amplitude and interferometric coherence images. On the basis of our results, we conclude that incidence angles of approximately 20–40°, linear polarization or surface scattering component (HH, VV, and HH + VV), and high resolution are the preferable conditions for flood area detection by PALSAR-2. The optimum threshold resulted in the following flood area detection accuracies: Kappa coefficient (κ) = 0.583 in open water and κ = 0.429 in built-up area. These results successfully demonstrate the feasibility of rapid flood monitoring using PALSAR-2 data.

21 January 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
ESEDSON SANO
EDSON SANO
PRPaola Rizzoli
Paola Rizzoli
CKChristian Koyama
Christian Koyama
Manabu WatamaneManabu Watamane
Manabu Watamane
MAMarcos Adami
Marcos Adami
DFDaniel M. Freitas
Daniel M. Freitas
Global-scale forest/non-forest (FNF) maps are of crucial importance for applications like biomass estimation and deforestation monitoring. Global FNF maps based on optical remote sensing data have been produced by the wall-to-wall satellite image analyses or sampling strategies. The German Aerospace Center (DLR) and the Japan Aerospace Exploration Agency (JAXA) also made available their global FNF maps based on synthetic aperture radar (SAR) data. This paper attempted to answer the following scientific question: how comparable are the FNF products derived from optical and SAR data? As test sites we selected the Amazon (tropical rainforest) and Cerrado (tropical savanna) biomes, the two largest Brazilian biomes. Forest estimations from 2015 derived from TanDEM-X (X band; HH polarization) and ALOS-2 (L band; HV polarization) SAR data, as well as forest cover information derived from Landsat 8 optical data were compared with each other at the municipality and image sampling levels. The optical-based forest estimations considered in this study were derived from the MapBiomas project, a Brazilian multi-institutional project to map land use and land cover (LULC) classes of an entire country based on historical time series of Landsat data. In addition to the existing forest maps, a set of 1619 Landsat 8 RGB color composites was used to generate new independent comparison data composed of circular areas with 5-km diameter, which were visually interpreted after image segmentation. The Spearman rank correlation estimated the correlation among the data sets and the paired Mann–Whitney–Wilcoxon tested the hypothesis that the data sets are statistically equal. Results showed that forest maps derived from SAR and optical satellites are statistically different regardless of biome or scale of study (municipality or image sampling), except for the Cerrado´s forest estimations derived from TanDEM-X and ALOS-2. Nevertheless, the percentage of pixels classified as forest or non-forest by both SAR sensors were 90% and 80% for the Amazon and Cerrado biome, respectively, indicating an overall good agreement.