A new test method of reciprocating magnetorheological polishing was presented and designed, and the mechanism of the micro-removal and the characteristics of the reciprocating magnetorheological polishing were analyzed. According to the reciprocating magnetorheological polishing experimental setup, the preparation process and proportion of the magnetorheological polishing fluid were studied. On the basis of analyzing the composition and characteristics of each component, the working parameters of the prepared magnetorheological polishing fluid were tested. With magnetorheological polishing fluid it prepared and reciprocating magnetorheological polishing method, the magnetorheological polishing experiments of borosilicate glass (K9) were carried out. The results show the effectiveness of the prepared magnetorheological polishing fluid and the practicability of the reciprocating magnetorheological polishing method.
In this study, a new reciprocating magnetorheological polishing (RMRP) method for a flat workpiece was proposed. Based on the RMRP principle and Preston equation, the material removal rate (MRR) model of the RMRP as well as its normal polishing pressure model was established. On this basis, the effects of different technological parameters including workpiece rotation speed, eccentric wheel rotation speed and eccentricity on the MRR of the workpiece were investigated. The K9 optical flat glass was polished with the RMRP setup to verify the MRR model. The experimental results showed that the effect of workpiece rotation speed on the MRR was much greater than that of eccentric wheel rotation speed and eccentricity, and the MRR increased from 0.0115 ± 0.0012 to 0.0443 ± 0.0015 μm/min as workpiece rotation speed rose. The optimum surface roughness reduced to Ra 50.8 ± 1.2 from initial Ra 330.3 ± 1.6 nm when the technical parameters of the workpiece rotation speed of 300 rpm, the eccentric wheel rotation speed of 20 rpm and the eccentricity of 0.02 m were applied. The average relative errors between the theoretical and experimental values were 16.77%, 10.59% and 7.38%, respectively, according to the effects of workpiece rotation speed, eccentric wheel rotation speed and eccentricity on MRR.
In this paper, a magnetic field device applicable to reciprocating magnetorheological polishing (RMRP) is designed, and the influence of excitation current as well as working gap on the device's magnetic field performance is systematically studied. Specifically, the structure of the RMRP magnetic field device is configured and elaborated in detail, and a series of magnetic field simulations are further employed to analyze the variations in magnetic induction intensity within the polishing area induced by excitation current and working gap. In addition, RMRP experiments are conducted to evaluate how excitation current and working gap affect the final polishing results. The simulation results for the magnetic field device indicate that magnetic induction intensity in the polishing area is positively correlated with excitation current, yet negatively correlated with the working gap. When either the excitation current or the working gap is held constant, the magnetic induction intensity within the polishing area exhibits a non-monotonic trend of initial increase followed by decrease as radial distance increases. The RMRP experimental results demonstrate that at an excitation current of 4 A, the surface roughness of the specimen is reduced significantly, dropping from an initial 327 nm to a final 42 nm. Correspondingly, when the working gap is adjusted to 0.75 mm, the surface roughness of the specimen decreases from 322 to 41 nm.