The present study proposes the phase change material (PCM) as a thermal energy storage unit to ensure the stability and flexibility of solar-energy-based heating and cooling systems. A mathematical model is developed to evaluate the PCM melting process, considering the effect of nanoparticles on heat transfer. We evaluate the role of nanoparticles (Al2O3-, copper- and graphene-based nanofluids) in enhancing the performance of the melting process of phase change materials. The results show that natural convection due to the buoyancy effect dominates the flow behaviour even in the initial stage of the PCM melting process. High natural convection at the bottom of the annular tube moves the melted PCM upward from the lateral, which pushes the liquid–solid interface downward. The addition of 3% vol Al2O3 nanoparticles boosts PCM melting performance by decreasing the melting time of PCM by approximately 15%. The comparison of Al2O3, copper and graphene nanoparticles demonstrates that higher thermal conductivity, ranging from 36 to 5000 W m−1 K−1, does not contribute to a significant improvement in the melting performance of PCMs.
Due to the rise in awareness of global warming, many attempts to increase efficiency in the automotive industry are becoming prevalent. Design optimization can be used to increase the efficiency of electric vehicles by reducing aerodynamic drag and lift. The main focus of this paper is to analyse and optimise the aerodynamic characteristics of an electric vehicle to improve efficiency of using computational fluid dynamics modelling. Multiple part modifications were used to improve the drag and lift of the electric hatchback, testing various designs and dimensions. The numerical model of the study was validated using previous experimental results obtained from the literature. Simulation results are analysed in detail, including velocity magnitude, drag coefficient, drag force and lift coefficient. The modifications achieved in this research succeeded in reducing drag and were validated through some appropriate sources. The final model has been assembled with all modifications and is represented in this research. The results show that the base model attained an aerodynamic drag coefficient of 0.464, while the final design achieved a reasonably better overall performance by recording a 10% reduction in the drag coefficient. Moreover, within individual comparison with the final model, the second model with front spitter had an insignificant improvement, limited to 1.17%, compared with 11.18% when the rear diffuser was involved separately. In addition, the lift coefficient was significantly reduced to 73%, providing better stabilities and accounting for the safety measurements, especially at high velocity. The prediction of the airflow improvement was visualised, including the pathline contours consistent with the solutions. These research results provide a considerable transformation in the transportation field and help reduce fuel expenses and global emissions.
Micro-cooling systems are compact refrigeration systems widely applicable in microchemical analysis, biomedicine, and microelectromechanical systems (MEMS). These systems rely on the use of micro-ejectors to achieve precise, fast, and reliable flow and temperature control. However, the efficiency of micro-cooling systems is hindered by spontaneous condensation occurring downstream of the nozzle throat and within the nozzle itself, impacting the performance of the micro-ejector. A micro-scale ejector mathematical model describing wet steam flow was simulated to investigate the steam condensation phenomenon and its influence on flow, incorporating equations for liquid phase mass fraction and droplet number density transfer. The simulation results of wet vapor flow and ideal gas flow were compared and analyzed. The findings revealed that the pressure at the micro-nozzle outlet exceeded predictions based on the ideal gas assumption, while the velocity fell below it. These discrepancies indicated that condensation of the working fluid reduces the pumping capacity and the efficiency of the micro-cooling system. Furthermore, simulations explored the impact of inlet pressure and temperature conditions on spontaneous condensation within the nozzle. The results demonstrated that the properties of the working fluid directly influence transonic flow condensation, underscoring the importance of selecting appropriate working fluid parameters for nozzle design to ensure nozzle stability and optimal micro-ejector operation.
The steam ejector is valuable and efficient in the fire suppression field due to its strong fluid-carrying capacity and mixing ability. It utilizes pressurized steam droplets generated at the exit to extinguish the fire quickly and the steam droplet strategy allows for an expressive decrease in water consumption. In this regard, the fire suppression process is influenced by the steam ejector efficiency, the performance of the pressurized steam, and the ejector core geometry, which controls the quality of the extinguishing mechanisms. This study investigated the impact of different mixing section diameters on the pumping performance of the ejector. The results showed that change in the diffuser throat diameter was susceptible to the entrainment ratio, which significantly increased, by 4 mm, by increasing the throat diameter of the diffuser and improved the pumping efficiency. Still, the critical back pressure of the ejector reduced. In addition, the diameter effect was studied and analyzed to evaluate the ejector performance under different operating parameters. The results revealed a rise in the entrainment ratio, then it diminished with increasing primary fluid pressure. The highest entrainment ratio recorded was 0.5 when the pressure reached 0.36 MPa at the critical range of back pressure, where the entrainment ratio remained constant until a certain back pressure value. Exceeding the critical pressure by increasing the back pressure to 7000 Pa permitted the entrainment ratio to reduce to zero. An optimum constant diameter maximized the ejector pumping efficiency under certain operating parameters. In actual design and production, it is necessary to consider both the exhaust efficiency and the ultimate exhaust capacity of the ejector.
The present study established an experimental system of steam ejector refrigeration to evaluate the effect of the operating parameters, such as pressure on the diffuser wall and primary and secondary fluid, on the performance and efficiency of the ejector. The model validation of numerical methods was carried out against the experimental data, while the numerical simulation was conducted by utilizing computational fluid dynamics modeling to analyze the internal flow of the ejector. The results indicated that the escalation of the primary steam pressure in the choking position increased the Mach number and entrainment ratio as the flow area of the secondary fluid remained constant. The optimization studies show that the entrainment ratio was maximum when the primary steam pressure was 0.36 MPa. While the pressure was inordinate, the expansion core increased in size and further compressed the flow area of the secondary fluid, hence reducing the entrainment ratio. Subject to the influence of the normal shockwave, the change in back pressure did not alter the entrainment ratio before the critical back pressure. In contrast, the ejector no longer produces the normal shockwave after the critical back pressure; the entrainment ratio, therefore, was reduced with the increase in back pressure.
Permanent-magnet brushless DC motors (PMBLDCMs) are widely used in various industrial applications. This paper proposed a fully analytical dynamic model of PMBLDCMs based on the armature reaction and subsequent commutation phenomenon. First, it introduced the PMBLDCM prototype, including the stator currents, electromagnetic torque, and rotor position calculated via electromotive force balance equations, the Maxwell stress tensor method, and motion formulas. Then, it employed the subdomain method under load conditions to analyze magnetic flux densities in the airgaps and the stator slots. Finally, it established a field-circuit coupling finite-element model (FEM) to verify magnetic flux densities, back-EMF, torque and rotor-position predictions. A 1.5 kW PMBLDCM prototype was built with back-EMF and stator-phase currents validated through experiments. In addition, torque and rotor-position results are validated against FEM instead of physical experiments.