The conformation of protein molecules is determined by a balance of various forces, including van der Waals attraction, electrostatic interaction, hydrogen bonding, and conformational entropy. When protein molecules encounter an interface, they are often adsorbed on the interface. The conformation of an adsorbed protein molecule strongly depends on the interaction between the protein and the interface. Recent time-resolved investigations have revealed that protein conformation changes during the adsorption process due to the protein-protein interaction increasing with increasing interface coverage. External conditions also affect the protein conformation. This review considers recent dynamic observations of protein adsorption at various interfaces and their implications for the kinetics of protein unfolding at interfaces.
9 April 2018 in The Journal of Physical Chemistry B
Protein unfolding at an air–water interface has been demonstrated such that the X-ray reflectivity can be measured with an acquisition time of 1 s using a recently developed simultaneous multiple-angle–wavelength-dispersive X-ray reflectometer. This has enabled the electron density profile of the adsorbed protein molecules to be obtained in real time. A globular protein, lysozyme, adsorbed at the air–water interface is found to unfold into a flat shape within 1 s.
Small-angle x-ray scattering measurements using a brilliant x-ray source revealed nanometer sized liquid droplets in a mist formed by ultrasonic atomization. Ultrasonic atomization of ethanol-water mixtures produced a combination of water-rich droplets of micrometer order and ethanol-rich droplets as small as , which is times smaller than the predicted size. These sizes were also obtained for mists generated from the pure liquids. These results will help to clarify the mechanism of “ultrasonic ethanol separation,” which has the potential to become an alternative to distillation.
24 March 2017 in Journal of Applied Crystallography
An X-ray reflectometer using a laboratory X-ray source for quick measurements of the specular X-ray reflectivity curve is presented. It uses a bent–twisted crystal to monochromatize and focus the diverging X-rays (Cu Kα1) from a laboratory point source onto the sample. The reflected X-rays are recorded with a two-dimensional detector. Reflectivity curves can be measured without rotating the sample, detector or X-ray source during measurements. The instrument can separate the specularly reflected X-rays from the diffuse scattering background, so low reflectivities can be measured accurately. For a gold thin film on silicon, the reflectivity down to the order of 10−6 was obtained with a measurement time of 100 s and that down to 10−5 with a measurement time of 10 s. Reflectivity curves of a silicon wafer and a liquid ethylene glycol surface are shown as well. Time-resolved measurements of a TiO2 surface during UV irradiation are also reported.