Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011‐2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi‐family apartment buildings and correlated the bioaerosol concentrations with building ventilation system types and environmental parameters. A total of 409 indoor and 86 outdoor samples were taken. Eighty‐five percent of investigated apartments had indoor‐outdoor (I/O) ratios of culturable fungi below 1, suggesting minimal indoor sources of fungi. In contrast, 56% of the apartments had I/O ratios for culturable bacteria above 1, indicating the prominence of indoor sources of bacteria. Culturable fungi I/O ratios in apartments serviced by central heating, ventilation, and air‐conditioning (HVAC) system were lower than those in apartments with window AC. The type of ventilation system did not have a significant effect on the presence of indoor culturable bacteria. A significant positive association was determined between indoor dew point (DP) levels and indoor culturable fungi (P < .001) and bacteria (P < .001), regardless of ventilation type. Also, residents in apartments with central HVAC did not experience extreme DP values. We conclude that building ventilation systems, seasonality, and indoor sources are major factors affecting indoor bioaerosol levels in residential buildings.
1 August 2020 in International Journal of Hygiene and Environmental Health
Despite the known human health risks associated with excessive heat exposure, particularly in occupational settings, data describing potential heat exposures in school kitchens is scarce, and no published studies to date have performed a quantitative heat exposure assessment for workers employed in this setting. The purpose of this study was to quantify the extent of heat stress in New York City public school kitchens and to assess potential risk of heat-related illness and/or acute injury. Full-shift indoor Wet Bulb Globe Temperature (WBGT) indices, as well as indoor CO2 and CO concentrations were measured for ten school kitchens. A quantitative exposure assessment for three metabolic work-rate scenarios (light, moderate, heavy) was performed in accordance with the Occupational Safety and Health Administration’s (OSHA) Heat Hazard Assessment methodology. The overall mean indoor WBGT index for all ten sites was approximately 25.0 °C (77.0 °F; Standard Deviation [SD] = 2.0 °C). Regarding the estimated Action Limit, 10% of school kitchens sampled exceeded this recommended limit for the light work-rate scenario; 60% of schools exceeded this limit for the moderate work-rate scenario; and 80% of schools exceeded this limit for the heavy work-rate scenario. For the Threshold Limit Value (TLV), none of the kitchens exceeded this limit for the light or moderate work-rate scenarios; 30% of kitchens were in excess of this limit for the heavy work-rate scenario. Mean full-shift CO2 and CO air concentrations ranged from 435–911 ppm (mean = 648; SD = 158) and 0.0–3.2 ppm (mean = 0.9; SD = 0.9), respectively. The data collected in the current study suggest that kitchen staff employed in New York City public schools may be exposed to excessive indoor heat levels. Adequate work-rest schedules should be implemented for kitchen workers, in addition to other feasible engineering and administrative controls to mitigate potential risk of heat-related illness and/or acute injury.
18 November 2021 in Archives of Environmental Contamination and Toxicology