Arne Gloe

Mr. Arne Gloe


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2016 in Energies
Verified
Journal Article
Open access
PDF file
HTHenning Thiesen
Henning Thiesen
CJClemens Jauch
Clemens Jauch
AGArne Gloe
Arne Gloe
In alternating current (AC) power systems the power generated by power plants has to match the power drawn by consumers plus the system losses at any time. In the case of an imbalance between generation and consumption the frequency in the system deviates from its rated value. In order to avoid an unsuitable frequency, control power plants have to step in to level out this imbalance. Control power plants need time to adjust their power, which is why the inertial behaviour of today’s AC systems is crucial for frequency control. In this paper it is discussed that the inertia in the European Continental Synchronous Area decreases due to the transition to renewable energy sources. This will become a problem for frequency control, which is why the provision of non-inherent inertia is proposed. This system consists of fast-responding energy storage. Its dimensions in terms of power and energy are determined. Since such non-inherent inertia requires investments a cost-efficient solution has to be found. Different technologies are compared in terms of the newly-introduced levelised cost of inertia. This paper concludes with the proposal that in future inertia should be traded and with the recommendation to use flywheels for this purpose, as these are the most cost-efficient solution for this task.

15 February 2019 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
AGArne Gloe
Arne Gloe
CJClemens Jauch
Clemens Jauch
BCBogdan Craciun
Bogdan Craciun
JWJörg Winkelmann
Jörg Winkelmann
In future power systems with little system inertia, grid operators will require the provision of synthetic inertia (SI) from renewable energy sources. Unlike today, grid operators may require continuous provision of SI. This can lead to an unwanted disconnection of wind turbine generators (WTGs) from the grid, and has the potential to cause a significant decrease of the energy yield and financial losses for the turbine operator. In order to avoid such situations a controller is proposed, which interprets the grid codes to the benefit of all parties involved. This can be achieved by a variable inertia constant, which changes with the operating point of the WTG. In this study, the behaviour of the variable inertia constant controller is described, assessed and verified with time domain simulations.

18 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
AGArne Gloe
Arne Gloe
CJClemens Jauch
Clemens Jauch
Thomas RätherThomas Räther
Thomas Räther
The work presented in this paper aims to show how modern wind turbines can help to control the frequency in a small grid which suffers from large power imbalances. It is shown for an exemplary situation, which occurred in Flensburg’s distribution grid in 2019: a major blackout, which occurred after almost two hours in islanding operation, affecting almost the entire distribution grid, which supplies approximately 55,000 households and businesses. For the analysis, a wind turbine model and a grid support controller developed at the Wind Energy Technology Institute are combined with real measurements from the day of the blackout to generate a fictional yet realistic case study for such an islanding situation. For this case study, it is assumed that wind turbines with grid support functionalities are connected to the medium voltage distribution grid of the city. It is shown to what extent wind turbines can help to operate the grid by providing grid frequency support in two ways: By supplying synthetic inertia only, where the wind turbines can help to limit the rate of change of frequency in the islanded grid directly after losing the connection to the central European grid. In combination with the primary frequency control capabilities of the wind turbines (WTs), the disconnection of one gen set in the local power station might have been avoided. Furthermore, wind turbines with primary frequency control capabilities could have restored the grid frequency to 50 Hz shortly after the islanding situation even if the aforementioned gen-set was lost. This would have allowed connecting a backup medium voltage line to the central European grid and thereby avoiding the blackout.

22 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
AGArne Gloe
Arne Gloe
CJClemens Jauch
Clemens Jauch
BCBogdan Craciun
Bogdan Craciun
AZArvid Zanter
Arvid Zanter
JWJörg Winkelmann
Jörg Winkelmann
In many electrical grids, the share of renewable energy generation increases. As these generators are typically connected to the grid via inverters, the level of grid inertia decreases. Such grids may therefore suffer from high rates of change of frequency during power imbalances. Modern wind turbines can help in controlling the frequency in such grids by providing synthetic inertia. A controller to provide synthetic inertia with wind turbines was developed at the Wind Energy Technology Institute in collaboration with Suzlon Energy. For this controller the influence of providing synthetic inertia on the mechanical loads of the wind turbine is assessed for different grid frequency scenarios. Such a scenario-based load analysis has not been published before, especially as the scenarios are derived from real measurements. The effect of the loads strongly depends on the analyzed grid frequency behavior. Ten months of high quality grid frequency measurements of the Indian grid are analyzed in order to derive inputs for the load calculation. Different types of grid frequency abnormities are identified and categorized with respect to their severity. Based on the observed occurrences of the grid frequency abnormities, realistic scenarios for the load calculations are chosen. The load calculations are performed for a state-of-the-art Suzlon wind turbine generator. The load increases caused by the supply of synthetic inertia are calculated for individual components assuming an otherwise undisturbed power production of the wind turbine in turbulent wind. Furthermore, a hardware-in-the-loop test bench is used to show how the measured grid frequencies are actually perceived by the control system of a typical wind turbine. The original frequency data were recorded with high quality measurement equipment, which is faster and more accurate than a multi-function relay, often used in wind turbines. For exemplary time traces, the effect of the reduced measurement accuracy on the reaction of the wind turbine is shown. This aspect has not been investigated in the literature yet. The results show that wind turbines can provide synthetic inertia without a considerable effect on the lifetime of the wind turbine. However, there are still problems with providing synthetic inertia reliably at high power operating points, which have to be solved.

5 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
CJClemens Jauch
Clemens Jauch
AGArne Gloe
Arne Gloe
This paper presents findings of a study on continuous feed-in management and continuous synthetic inertia contribution with wind turbines. A realistic case study, based on real measurements, is outlined. A wind turbine feeds into a weak feeder, such that its power has to be adapted to the permissible loading of this feeder. At the same time the wind turbine is to provide inertia to the grid by applying the previously published variable inertia constant controller. It is discussed that optimal grid utilization and simultaneous inertia contribution are mandatory for the frequency control in power systems that are heavily penetrated with renewable energies. The study shows that continuous feed-in management can be combined well with continuous inertia provision. There are hardly any negative consequences for the wind turbine. The benefits for the grid are convincing, both in terms of increased system utilization and in terms of provided inertia. It is concluded that wind turbines can enhance angular stability in a power system to a larger extent than conventional power plants.

5 June 2019 in Preprints.org
Verified
Preprint
Open access
PDF file
CJClemens Jauch
Clemens Jauch
AGArne Gloe
Arne Gloe
This paper presents findings of a study on continuous feed-in management and continuous synthetic inertia contribution with wind turbines. A realistic case study, based on real measurements, is outlined. A wind turbine feeds into a weak feeder, such that its power has to be adapted to the permissible loading of this feeder. At the same time the wind turbine is to provide inertia to the grid by applying the previously published variable inertia constant controller. It is discussed that optimal grid utilisation and simultaneous inertia contribution are mandatory for the frequency control in power systems that are heavily penetrated with renewable energies. The study shows that continuous feed-in management can be combined well with continuous inertia provision. There are hardly any negative consequences for the wind turbine. The benefits for the grid are convincing, both in terms of increased system utilisation and in terms of provided inertia. It is concluded that wind turbines can enhance angular stability in a power system to a larger extent than conventional power plants.