In alternating current (AC) power systems the power generated by power plants has to match the power drawn by consumers plus the system losses at any time. In the case of an imbalance between generation and consumption the frequency in the system deviates from its rated value. In order to avoid an unsuitable frequency, control power plants have to step in to level out this imbalance. Control power plants need time to adjust their power, which is why the inertial behaviour of today’s AC systems is crucial for frequency control. In this paper it is discussed that the inertia in the European Continental Synchronous Area decreases due to the transition to renewable energy sources. This will become a problem for frequency control, which is why the provision of non-inherent inertia is proposed. This system consists of fast-responding energy storage. Its dimensions in terms of power and energy are determined. Since such non-inherent inertia requires investments a cost-efficient solution has to be found. Different technologies are compared in terms of the newly-introduced levelised cost of inertia. This paper concludes with the proposal that in future inertia should be traded and with the recommendation to use flywheels for this purpose, as these are the most cost-efficient solution for this task.
Power system inertia is a vital part of power system stability. The inertia response within the first seconds after a power imbalance reduces the velocity of which the grid frequency changes. At present, large shares of power system inertia are provided by synchronously rotating masses of conventional power plants. A minor part of power system inertia is supplied by power consumers. The energy system transformation results in an overall decreasing amount of power system inertia. Hence, inertia has to be provided synthetically in future power systems. In depth knowledge about the amount of inertia provided by power consumers is very important for a future application of units supplying synthetic inertia. It strongly promotes the technical efficiency and cost effective application. A blackout in the city of Flensburg allows for a detailed research on the inertia contribution from power consumers. Therefore, power consumer categories are introduced and the inertia contribution is calculated for each category. Overall, the inertia constant for different power consumers is in the range of to s if inertia constant calculations are based on the power demand. If inertia constant calculations are based on the apparent generator power, the load inertia constant is in the range of to s.
This paper presents a study to assess how wind turbines could increase their energy yield when their grid connection point is not strong enough for the rated power. It is state of the art that in such situations grid operators impose feed-in management on the affected wind turbines, i.e., the maximum power is limited. For this study a 5 MW wind turbine is introduced in a small grid that has only limited power transfer capabilities to the upstream power system. Simulations of one particular day are conducted with the electric load, the temperature, and the wind speed as measured on that day. This simulation is conducted twice: once with the 5 MW wind turbine controlled with conventional feed-in management, and a second time when its power is controlled flexibly, i.e., with continuous feed-in management. The results of these two simulations are compared in terms of grid performance, and in terms of mechanical stress on the 5 MW wind turbine. Finally, the conclusion can be drawn that continuous feed-in management is clearly superior to conventional feed-in management. It exhibits much better performance in the grid in terms of energy yield and also in terms of constancy of voltage and temperature of grid equipment. Although it causes somewhat more frequent stress for the wind turbine, the maximum stress level is not increased.
Power system inertia is an essential part for grid frequency stability and decreases due to the replacement of fossil fuel fired power plants with variable renewable energy sources. This development is not represented sufficiently in unit commitment and economic dispatch models. If considered at all, only synchronous inertia from fossil fuel driven power plants is modelled. This results in increased CO emissions, curtailed renewable energy and high system costs. While wind turbines are a source for synthetic inertia and an important renewable energy source, their capability to provide inertia is not incorporated into energy system models. The work at hand closes this research gap and applies a methodology to depict synthetic inertia provided by wind turbines as part of the optimisation dispatch model. A unit commitment and economic inertia dispatch model of the the all-Island Irish power system is created. The potential of wind inertia is analysed and quantified by assessing CO emissions, curtailed renewable energy and system costs. Results show that synthetic inertia provided by wind turbines can save up 30.99% of the CO emissions, reduce curtailment by up to 39.90% and reduce system costs by 32.72%.
Increasing the share of grid frequency converter-connected renewables reduces power system inertia, which is crucial for grid frequency stability. However, this development is insufficiently covered by energy system modelling and analysis as well as related scientific literature. Additionally, only synchronous inertia from fossil fuel-emitting power plants is represented, although renewable generators are a source of synthetic inertia, thus resulting in increased must-run capacities, CO2 emissions and system costs. The work at hands adds an analysis of the future German power system considering sufficient inertia to the literature. Therefore, results of an novel open-source energy system model are analysed. The model depicts minimum system inertia constraints as well as wind turbines and battery storage systems as a carbon-dioxide-free source for a synthetic inertial response. Results indicate that integrating system inertia constraints in energy system models has a high impact on indicators such as system costs. Especially when investments in additional storage units providing an inertial response are necessary. With respect to researched scenarios, system cost increases range from 1% up to 23%. The incremental costs for providing additional inertia varies between 0.002 EURO/kg·m2 and 0.61 EURO/kg·m2.
Power system inertia is an essential part of grid frequency control. The number of synchronously connected machines, which inherently provide inertia, is decreasing due to the transition to renewable energies. Conventional generation units are being replaced by renewable generation units which are connected to the grid via frequency converters. Some power systems already suffer from too little power system inertia. Hence, inertia is a valuable yet non-traded commodity. A day-ahead dispatch methodology to secure power system inertia was developed and is applied and assessed in this work. Day-ahead market data of the combined market of the Republic of Ireland and Northern Ireland is used. If the superimposition of sell and buy bids results in insufficient inertia, the dispatch algorithm is applied. In decreasing price order, non-inertia-providing sell bids get replaced by the following sell bids in the merit order. The iterative process is repeated until sufficient inertia is in the system. The provision of synthetic inertia by wind turbines is considered in the process. The costs for additional stored kinetic energy for the assessed time periods and scenarios result in costs ranging from 1.02 to 4.49 EUR/kgm2.