A calibration algorithm based on one-port vector network analyzer (VNA) calibration for scanning microwave microscopes (SMMs) is presented and used to extract quantitative carrier densities from a semiconducting n-doped GaAs multilayer sample. This robust and versatile algorithm is instrument and frequency independent, as we demonstrate by analyzing experimental data from two different, cantilever- and tuning fork-based, microscope setups operating in a wide frequency range up to 27.5 GHz. To benchmark the SMM results, comparison with secondary ion mass spectrometry is undertaken. Furthermore, we show SMM data on a GaAs p-n junction distinguishing p- and n-doped layers.
Reference samples are commonly used for the calibration and quantification of nanoscale electrical measurements of capacitances and dielectric constants in scanning microwave microscopy (SMM) and similar techniques. However, the traceability of these calibration samples is not established. In this work, we present a detailed investigation of most possible error sources that affect the uncertainty of capacitance measurements on the reference calibration samples. We establish a comprehensive uncertainty budget leading to a combined uncertainty of 3% in relative value (uncertainty given at one standard deviation) for capacitances ranging from 0.2 fF to 10 fF. This uncertainty level can be achieved even with the use of unshielded probes. We show that the weights of uncertainty sources vary with the values and dimensions of measured capacitances. Our work offers improvements on the classical calibration methods known in SMM and suggests possible new designs of reference standards for capacitance and dielectric traceable measurements. Experimental measurements are supported by numerical calculations of capacitances to reveal further paths for even higher improvements.
30 April 2020 in Measurement Science and Technology
This paper presents a calibration method and an uncertainty budget for capacitance measurements performed on micrometric size capacitors at microwave frequencies and nanometric resolution using a scanning microwave microscopy (SMM). The method applies the classical one-port vector network analyzer calibration for SMM using three known capacitance standards. These standards are established from a commercial calibration kit placed close to the microcapacitors in order to be calibrated. The calibration kit is composed of a large number of Metal-Oxide-Semiconductor (MOS) microcapacitors with capacitance values C ranging from 0.1 fF to 8.6 fF. Diligent selection criteria were established for the choice of the three capacitors. Their capacitance values were calculated from the AFM measured values of the area of the top electrodes and the dielectric thickness and considering the contribution of fringing fields. The combined type uncertainty on these calculated values amounts between 5% and 14% in relative value (uncertainty given at one standard deviation). The comparison between the capacitance values measured on calibration kit capacitors using the calibrated SMM and the calculated values show a good agreement for capacitances higher than 0.8 fF within uncertainties varying between 6% and 9%. For smaller capacitances, most of the observed deviations are not significant at two standard deviations. The uncertainties are mostly dominated by dimensional measurements and less importantly by unwanted capacitance effects. Based on these results, capacitances of two sets of microcapacitors were calibrated. The combined uncertainties vary from 14% to 7% for capacitances ranging from 0.1 fF to 3.1 fF respectively. The permittivity values of the dielectric layer of the two samples have been determined. They are found equal to 4.0 and 4.1 with a standard uncertainty of 0.6 and correlate with the expected value of 3.9.
20 March 2024 in IEEE Transactions on Instrumentation and Measurement
In this paper, a definition of the gain and added noise of impedance matching networks for scanning microwave microscopy is given. This definition can be used to compare different impedance matching techniques independently of the instrument used to measure the S-parameter. As a demonstration, impedance matching devices consisting of a Beatty line, a tuner, and interferometric setups with and without amplifiers have been investigated. Measurement frequencies up to 28 GHz are used, and the maximal resulting gain found was 9504.7 per Siemens.
Metrology dedicated to electricity and magnetism has changed considerably in recent years. It encompasses almost all modern scientific, industrial, and societal challenges, e.g. the revision of the International System of Units, the profound transformation of industry, changes in energy use and generation, health, and environment, as well as nanotechnologies (including graphene and 2D materials) and quantum engineering. Over the same period, driven by the globalization of worldwide trade, the Mutual Recognition Arrangement (referred to as the CIPM MRA) was set up. As a result, the regional metrology organizations (RMOs) of national metrology institutes have grown in significance. EURAMET is the European RMO and has been very prominent in developing a strategic research agenda (SRA) and has established a comprehensive research programme. This paper reviews the highlights of EURAMET in electrical metrology within the European Metrology Research Programme and its main contributions to the CIPM MRA. In 2012 EURAMET undertook an extensive roadmapping exercise for proposed activities for the next decade which will also be discussed in this paper. This work has resulted in a new SRA of the second largest European funding programme: European Metrology Programme for Innovation and Research.