20 March 2024 in IEEE Transactions on Instrumentation and Measurement
In this paper, a definition of the gain and added noise of impedance matching networks for scanning microwave microscopy is given. This definition can be used to compare different impedance matching techniques independently of the instrument used to measure the S-parameter. As a demonstration, impedance matching devices consisting of a Beatty line, a tuner, and interferometric setups with and without amplifiers have been investigated. Measurement frequencies up to 28 GHz are used, and the maximal resulting gain found was 9504.7 per Siemens.
3 April 2023 in IEEE Transactions on Instrumentation and Measurement
This paper describes a method to model the impedance of a Haddad type resistor over a frequency interval ranging from 10 to 200 MHz, hereafter defined as LF-RF range. To this end, novel resistor standards, of 1 kΩ and 100 Ω, have been designed and manufactured with the aim of sharply identifying the nodes that define the impedance. Resistor modelling is divided into two main parts: the first one, describing the central coaxial core and the second part, describing the connectors through physical simulations and a subsequent analytical approach. The results show a remarkable good agreement between measured and modelled impedance over the whole considered frequency range. Uncertainty values allow for the traceability of the resistors up to high frequencies and for the calibration of commercial impedance analyzers within the LF-RF range.
16 May 2024 in Measurement Science and Technology
Scanning microwave microscopy (SMM) is a combination of an atomic force microscope with a vector network analyzer (VNA) to measure locally resolved impedances. The technique finds application in the realms of semiconductor industries, material sciences, or biology. To determine quantitative material properties from the measured impedances, the system must be calibrated. Transferring the calibration from the calibration substrate onto the material under test is strongly limited when using unshielded probes, as the electromagnetic coupling to the surroundings can reach several centimeters. This work reports the fabrication of coaxially shielded probes for a scanning microwave microscope and their integration into such an instrument. We discuss a calibration method with dielectric references, using a simulation-assisted 1-port VNA calibration algorithm. Uncertainty considerations of the measurement process are included and propagation throughout the algorithm is performed. The calibration is verified with an additional dielectric reference. As an application example, the results for a static-random-access memory sample are presented. We identified system-related drift and trace noise as the dominant contributors to the uncertainties of the calibrated results. The here presented shielded tips can broaden the application scope of SMM, as they are door-openers for measurements in liquids.
19 February 2025 in Physica Status Solidi (a)
Indium tin oxide (ITO), a transparent conductive oxide, is widely used in optoelectronic applications due to its electrical conductivity, optical transparency, and chemical stability. This study employs spectroscopic ellipsometry (SE) to analyze ITO layers, enabling nondestructive determination of film thickness, dielectric functions, and bulk conductivity. Electrical properties derived from SE are compared with those obtained using the four‐point probe method (4PM) to improve metrological tools for nanotechnology applications and optimize deposition process monitoring for better control of film properties. This work also investigates the chemical stability of ITO layers under etching conditions and explores the development of new sheet resistance standards for scanning microwave microscopy (SMM). The results show that ITO resistivity, calculated from fitted SE data, increases with oxygen flow rate up to 5 cm3(STP) min−1. Good agreement is observed between sheet resistance values obtained by SE and 4PM up to 3 cm3(STP) min−1. Additionally, the sheet resistance values of a distinct set of microstructured ITO samples with different ITO layer thicknesses are determined by SMM, which are highly consistent with those obtained by the 4PM.