This study presents an analytical and experimental method for detecting internal turn-to-turn short circuits both in the rotor or in the stator in salient pole synchronous generator machines (SSGM) connected to local power grid. Two main measurements are proposed to confirm or discard these electric faults: external magnetic field and external housing vibrations (EHV). In the event of a short-circuit winding fault, a correlation between external magnetic field and EHV is done to reinforce the diagnosis. Furthermore, the electric power injection dependence is analyzed and a noninvasive technique is proposed to determine the state of the SSGM whatever its load. Thus, it is shown that only noninvasive and online equipment can be used to diagnose SSGM. A diagnostic tool has been developed to show the viability of an operative wireless monitoring system on a 76-MW SSGM in an industrial environment.
This paper presents a non invasive method for estimating the energy efficiency of induction motors used in industrial applications. This method is innovative because it is only based on the measurement of the external field emitted by the motor. The paper describes the sensors used, how they should be placed around the machine in order to decouple the external field components generated by both the air gap flux and the winding end-windings. The study emphasizes the influence of the eddy currents flowing in the yoke frame on the sensor position. A method to estimate the torque from the external field use is proposed. The measurements are transmitted by a wireless module (Zig-Bee) and they are centralized and stored on a PC computer.
An experimental method to characterize the magnetic properties of Grain Oriented Electrical Steel in the rolling direction is proposed in this paper. It relies on the use of three 25 cm Epstein frames combined to generate three test-frames of different lengths. This enables the identification of the effective specific losses of the electrical steel when magnetization is applied along the rolling direction. As a consequence, it evidences the deviation of the loss figures obtained using the standardised Epstein test. The difference in losses is explained by the fact that the described method gives “only” the losses attached to the straight parts. The concept of the magnetic path length as defined by the standard is discussed.
The most common method for the electrical steel sheet characterization uses the Epstein frame. However, in the case of high-temperature characterization, the standard Epstein frame is not adapted. This paper deals with the design of a frame adapted to high temperature, up to 600 °C. In a first step, the results at ambient temperature obtained between the normalized Epstein frame and the high-temperature device for different frequencies are compared in order to validate the new frame. The second step is dedicated to the characterization of soft ferromagnetic materials in high temperature, up to 600 °C and for different frequencies. Moreover, the effect of sheet thickness on their behavior has been studied at high temperatures. The obtained measurement results confirm the strong influence of both temperature and thickness on power losses.
27 December 2021 in IEEE Transactions on Magnetics
This article presents the potential contribution of segmented stator magnetic circuits of rotating permanent magnet electrical machines with concentric winding. Two magnetic materials are mixed: FeSi non-oriented electrical steel and FeSi grain-oriented electrical steel (GOES). The choice of using GOES is based on the high performance it offers in terms of permeability and iron losses compared to conventional non-oriented grain electrical steel (NOES), particularly when GOES is magnetized in the rolling direction (RD). The goal is to analyze the contribution of the mixed magnetic circuit on the losses and electromagnetic torque but also the drawbacks due to the cut process and the assembly. The behavior of the magnetic field at the junction between the segments is studied by comparing different geometrical connection shapes and compared to a reference magnetic circuit fully made with NOES sheets. This comparison is experimentally made with a model representative of the existing phenomena in an electrical machine. In addition, numerical calculations using finite elements software are carried out by considering both the magnetic anisotropy and the saturation of the GOES.
1 January 2011 in Progress In Electromagnetics Research
This paper focuses on the noise and vibrations of induction motors. It proposes an analytical method to distinguish the phenomenon responsible on the magnetic noise, especially the toothing and the saturation. A 3-speed 3-phase induction motor, which works sporadically at low speed for hoisting, serve as a support for experiments. Its acoustic noise during this operating mode is really important. A complete diagnosis is proposed with a 2D analytical model. The approach is progressive and it shows analytically that magnetic saturation is mainly responsible on these noise level. Then, the presented developments makes it possible to identify, in simple way, the noise components due to the both magnetic saturation and toothing effects.