In building integrated photovoltaics (PV), it is important to solve the heat dissipation problem of PV modules. In this paper, the computational fluid dynamics (CFD) method is used to simulate the flow field around the open-joint photovoltaic ventilated double-skin façades (OJ-PV-DSF) to study the influence of the mounting dimensions (MD) of a PV array on the module temperature. The typical summer afternoon meteorological parameters, such as the total radiation (715.4 W/m2), the outdoor temperature (33.1 °C), and the wind speed (2.0 m/s), etc., are taken as input parameters. With the DO (discrete ordinates) model and the RNG (renormalization-group) k − ε model, a steady state calculation is carried out to simulate the flow of air in and around the cavity under the coupling of hot pressure and wind pressure, thereby obtaining the temperature distribution of the PV array and the wall. In addition, the simulation results are compared with the onsite experimental data and thermal imaging to verify the accuracy of the CFD model. Then three MD of the open joints are discussed. The results show that when the a value (represents the distance between PV modules and wall) changes from 0.05 to 0.15, the temperature drop of the PV module is the most obvious, reaching 2.0 K. When the b value (representing the distance between two adjacent PV modules in the vertical direction) changes from 0 to 0.1, the temperature drop of the PV module is most obvious, reaching 1 K. When the c value (represents the distance between two adjacent PV modules in the horizontal direction) changes from 0 to 0.1, the temperature of the PV module is lowered by 0.8 K. Thus, a = 0.1–0.15, b = 0.1 and c = 0.1 are recommended for engineering applications to effectively reduce the module temperature.
Based on the energy conversion equation and dynamic power model of the semi-transparent crystalline silicon photovoltaic (PV) window (ST-PVW), through an iterative coupling solution to the operating temperature of the cell, a thermal-electric coupling calculation method for the ST-PVW is provided, and, combined with experiments, the method model was verified. Based on this model, the influence of PV cell coverage rate (PVR) on the thermal performance of the ST-PVW was studied. According to the simulation results, in summer, the heat gain of the ST-PVW decreases with the increase of PVR, and in winter, the amount of heat loss increases with the increase of PVR. For the four cities of Guangzhou, Nanjing, Beijing and Harbin, when the PVR is 1, 0.60 to 0.64, 0.28 to 0.32 and 0.26 to 0.30, respectively, the annual power consumption of the air conditioner can reach the minimum, and when the PVR is 0.16 to 0.17, 0.24 to 0.25, 0.22 to 0.23 and 0.19 to 0.20, respectively, the amount of electricity generated can just offset the power consumption of the air conditioner during the day.