Wenjie Zhang

Dr. Wenjie Zhang

Nanjing University of Science and Technology, Nanjing, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
WZWenjie Zhang
Wenjie Zhang
SLShan Liu
Shan Liu
NLNianping Li
Nianping Li
HXHui Xie
Hui Xie
XLXuanqi Li
Xuanqi Li

28 July 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
WZWenjie Zhang
Wenjie Zhang
YZYuqiang Zhao
Yuqiang Zhao
FHFengcheng Huang
Fengcheng Huang
YZYongheng Zhong
Yongheng Zhong
JZJianwei Zhou
Jianwei Zhou
In recent years, with the rapid development of China’s economy, China’s energy demand has also been growing rapidly. Promoting the use of renewable energy in China has become an urgent need. This study evaluates the potential of solar photovoltaic (PV) power generation on the roofs of residential buildings in rural areas of mainland China and calculates the area that can used for generating energy, the installed capacity, and the power generation, and conducts a comprehensive analysis of the economic benefits of investing in the construction of distributed PV systems in various provinces. The findings unveiled in this study indicate that China still has more than 6.4 billion m2 of rural construction area available for the installation of PV modules. If this is all used for solar power generation, the annual power generation can reach up to 1.55 times the electricity consumption of urban and rural residents for the whole society. Through a comprehensive evaluation of energy efficiency and economic benefits, the Chinese mainland can be divided into three types of resource areas. The three types of resource areas have their own advantages and disadvantages. According to their own characteristics and advantages, we can reasonably formulate relevant policies to accelerate the development of PV system application in rural areas.

29 April 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
WZWenjie Zhang
Wenjie Zhang
GTGong Tongdan
Gong Tongdan
SMShengbing Ma
Shengbing Ma
JZJianwei Zhou
Jianwei Zhou
英赵英博 赵
英博 赵
In building integrated photovoltaics (PV), it is important to solve the heat dissipation problem of PV modules. In this paper, the computational fluid dynamics (CFD) method is used to simulate the flow field around the open-joint photovoltaic ventilated double-skin façades (OJ-PV-DSF) to study the influence of the mounting dimensions (MD) of a PV array on the module temperature. The typical summer afternoon meteorological parameters, such as the total radiation (715.4 W/m2), the outdoor temperature (33.1 °C), and the wind speed (2.0 m/s), etc., are taken as input parameters. With the DO (discrete ordinates) model and the RNG (renormalization-group) k − ε model, a steady state calculation is carried out to simulate the flow of air in and around the cavity under the coupling of hot pressure and wind pressure, thereby obtaining the temperature distribution of the PV array and the wall. In addition, the simulation results are compared with the onsite experimental data and thermal imaging to verify the accuracy of the CFD model. Then three MD of the open joints are discussed. The results show that when the a value (represents the distance between PV modules and wall) changes from 0.05 to 0.15, the temperature drop of the PV module is the most obvious, reaching 2.0 K. When the b value (representing the distance between two adjacent PV modules in the vertical direction) changes from 0 to 0.1, the temperature drop of the PV module is most obvious, reaching 1 K. When the c value (represents the distance between two adjacent PV modules in the horizontal direction) changes from 0 to 0.1, the temperature of the PV module is lowered by 0.8 K. Thus, a = 0.1–0.15, b = 0.1 and c = 0.1 are recommended for engineering applications to effectively reduce the module temperature.

14 December 2021 in Buildings
Verified
Journal Article
Open access
PDF file
WZWenjie Zhang
Wenjie Zhang
FHFengcheng Huang
Fengcheng Huang
KMKai Mao
Kai Mao
CLChangqing Lin
Changqing Lin
ZPZhen Pan
Zhen Pan
The environmental and energy crisis has become a problem that can not be ignored in today’s world and improving the proportion of renewable energy utilization is an important way to alleviate the problem. China has begun to vigorously develop rooftop photovoltaic systems, and it is urgent to analyze the photovoltaic potential of the country. In this paper, GIS technology is used to calculate the available area of a PV system on the roof of urban buildings in China. The installed capacity and annual power generation of a PV system on the roof of urban buildings in China are further calculated, and the investment cost analysis of the buildings with a PV system is carried out. The results show that Chinese mainland city rooftop photovoltaic area has reached 3.35 billion m2. If urban roofs are used for photovoltaic power generation in China, the annual photovoltaic power generation capacity will be 672 billion kWh, which is about 61% of the total annual electricity consumption of the whole society in 2020. On the other hand, the initial investment in the construction of an urban photovoltaic system is large, but most of them can realize the return of investment in a short period of 8–10 years. Moreover, in the effective life of the follow-up photovoltaic system, it will bring greater economic benefits, which is more than two times the initial investment. To further promote the process of social carbon peak and carbon neutrality in China, the construction of an urban photovoltaic system is very feasible.

20 December 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
TGTongdan Gong
Tongdan Gong
WZWenjie Zhang
Wenjie Zhang
JLJinhan Liang
Jinhan Liang
CLChangqing Lin
Changqing Lin
KMKai Mao
Kai Mao
Controlling the scale of civil buildings is of great significance for energy saving and emission reduction in the construction field. This paper analyzes and extracts the key index parameters for the calculation of various civil building areas, establishes a detailed calculation model of the total civil building area, and constructs three different scenarios to predict various civil building areas in China from 2020 to 2060. Under the three scenarios, the total amount of civil buildings in China will reach a peak of 93.5, 84.6, and 76.3 billion m2 in 2040, 2035, and 2035, respectively. Under the constraints of energy consumption and carbon emission, this paper suggests that civil buildings develop according to the medium control scenario. In 2035, the urban per capita residential area will reach a peak of 42 m2, the urban residential area will reach 43 billion m2, the rural per capita residential area will reach the peak of 55 m2, the rural residential area will reach 20.6 billion m2, and the public building area will reach 21 billion m2. By 2060, the total area of civil buildings will drop to 76.5 billion m2, including 37.1 billion m2 of urban residential buildings, 18.5 billion m2 of rural residential buildings, and 20.9 billion m2 of public buildings.

30 August 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
YZYu ZHENG
Yu ZHENG
XLXiaoming Li
Xiaoming Li
WZWenjie Zhang
Wenjie Zhang
KWKuan Wang
Kuan Wang
FHFeng Han
Feng Han
YZYuqiang Zhao
Yuqiang Zhao
In this paper, a phase change microcapsule suspension MPCMS25 with a mass fraction of 10% was prepared with TH-ME25 as the phase change microcapsule particles and deionized water as the base fluid. The experimental benches of the Building Integrated Photovoltaic (BIPV) system and BIPV-MPCMS system were set up, and the comparative tests were carried out in Nanjing to study the optimization effect of phase change microcapsule suspension on the thermal and electrical properties of the BIPV system. The results show that MPCMS25 reduces the component temperature of the system by 8.8 °C and the backplane temperature by 11.1 °C. The optimization time of the component operating temperature and the backplane temperature is 9.5 h and 9.75 h, respectively. Delay appearance of peak module operating temperature by 114 min and peak backplane temperature by 125 min. In addition, the suspension can also improve the power conversion efficiency (PCE) of photovoltaic modules by 0~5%. After a simulation study on the energy consumption of a high-speed railway station, it is found that using the BIPV-MPCMS system as the building envelope can achieve an energy saving rate of about 8.5%.