Mutations in the LMNA gene encoding Lamin A and C (Lamin A/C), major components of the nuclear lamina, cause laminopathies including dilated cardiomyopathy (DCM), but the underlying molecular mechanisms have not been fully elucidated. Here, by leveraging single-cell RNA sequencing (RNA-seq), assay for transposase-accessible chromatin using sequencing (ATAC-seq), protein array, and electron microscopy analysis, we show that insufficient structural maturation of cardiomyocytes owing to trapping of transcription factor TEA domain transcription factor 1 (TEAD1) by mutant Lamin A/C at the nuclear membrane underlies the pathogenesis of Q353R -LMNA– related DCM. Inhibition of the Hippo pathway rescued the dysregulation of cardiac developmental genes by TEAD1 in LMNA mutant cardiomyocytes. Single-cell RNA-seq of cardiac tissues from patients with DCM with the LMNA mutation confirmed the dysregulated expression of TEAD1 target genes. Our results propose an intervention for transcriptional dysregulation as a potential treatment of LMNA -related DCM.
Non-obstructive azoospermia (NOA) is a severe male infertility condition characterized by extremely low or absent sperm production. In microdissection testicular sperm extraction (Micro-TESE) procedures for NOA, embryologists must manually search through testicular tissue under a microscope for rare sperm, a process that can take 1.8–7.5 h and impose significant fatigue and burden. This paper presents an augmented reality (AR) microscope system with AI-based image analysis to accelerate sperm retrieval in Micro-TESE. The proposed system integrates a deep learning model (YOLOv5) for real-time sperm detection in microscope images, a multi-object tracker (DeepSORT) for continuous sperm tracking, and a velocity calculation module for sperm motility analysis. Detected sperm positions and motility metrics are overlaid in the microscope’s eyepiece view via a microdisplay, providing immediate visual guidance to the embryologist. In experiments on seminiferous tubule sample images, the YOLOv5 model achieved a precision of 0.81 and recall of 0.52, outperforming previous classical methods in accuracy and speed. The AR interface allowed an operator to find sperm faster, roughly doubling the sperm detection rate (66.9% vs. 30.8%). These results demonstrate that the AR microscope system can significantly aid embryologists by highlighting sperm in real time and potentially shorten Micro-TESE procedure times. This application of AR and AI in sperm retrieval shows promise for improving outcomes in assisted reproductive technology.
Purpose: Non-obstructive azoospermia (NOA) presents major challenges in assisted reproductive technology (ART) due to the extremely low number of viable sperm within testicular tissue. In Micro-TESE procedures, embryologists manually search for sperm under DIC microscopy—a slow, labor-intensive process. We aim to streamline this process with an efficient computational detection tool. Methods: We present SD-CLIP (Sperm Detection using Classical Image Processing), a lightweight, real-time algorithm that simulates sperm structure detection from unstained DIC images. The model first identifies convex sperm head candidates based on shape and width using edge gradients, then confirms the presence of a tail via principal component analysis (PCA) of pixel clusters. Results: Compared to the MB-LBP + AKAZE method, SD-CLIP improved processing speed by 4× and achieved a 3.8× higher posterior probability ratio, making detected sperm candidates significantly more reliable. Evaluation was performed on both human Micro-TESE and mouse testis images, demonstrating robustness in low-sperm environments. Conclusions: SD-CLIP simulates a domain-specific image interpretation model that identifies sperm morphology with high specificity. It requires minimal computational resources, supports real-time integration, and could be extended to automated sperm extraction systems. This tool has clinical value for accelerating Micro-TESE and increasing success rates in ART for NOA patients.
In this study, non-electrically controlled SalivaDirect loop-mediated isothermal amplification (NEC-SD-LAMP), which can detect infections by amplifying viral DNA expression in saliva without using electrical control systems, was developed. By this method, only by adding water to the device, viral DNA was extracted from saliva using SalivaDirect, the extracted DNA was amplified via loop-mediated isothermal amplification (LAMP), and the results were visually confirmed. Melting palmitic acid maintained the optimal temperature for the LAMP reaction, as the temperature of palmitic acid is maintained at 62.9 °C, its melting point. By exploiting the proximity of the melting point to the optimal temperature for LAMP, LAMP can be performed without electricity. We detected several viruses in the saliva using this method. NEC-SD-LAMP could clearly distinguish 3 types of viral DNA, indicating the high specificity of this reaction. Furthermore, the viral concentration detection limit of the device was 2 copies per µL, indicating that it is possible to detect DNA viral infections in saliva even before the onset of viral infection.
We can detect cancer in the early stages by validating the expression of cancer specific nucleic acids in the blood. In this report, we have developed the micro device for performing real-time polymerase chain reaction (real-time PCR), one of the methods used for determining the quantity of nucleic acids, using a small volume of reagent. This all-in-one device can perform real-time PCR with the inclusion of heating control and the analyzing system with optical sensor.