michel alsharidah

Prof. michel alsharidah


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2021 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
NENader A. El-Taweel
Nader A. El-Taweel
Hany E. FaragHany E. Farag
Hany E. Farag
Mostafa ShaabanMostafa Shaaban
Mostafa Shaaban
MAmichel alsharidah
michel alsharidah
This article proposes a new mathematical formulation for optimal operation scheduling for a remote photovoltaic (PV) farm and distributed electric vehicle charging stations (D-EVCSs), which are owned by a private entity. The proposed model is formulated to maximize the profit of the D-EVCSs private investor through optimal electric vehicle (EV) charging coordination and pricing mechanism. The proposed pricing mechanism aims to achieve an expected revenue by the private investor, while guaranteeing a low charging price for EVs to ensure the EV owners’ satisfaction. For the EV supply application, D-EVCS integrates a battery storage system and rooftop PV. However, the rooftop PV installation is constrained to the limited footprint of the EVCS. For this reason, the investment in a remote PV farm and its impact on the expected revenue and the EVs charging price is introduced in this article. The power generated by the remote PV farm can be transacted to the D-EVCSs using a power purchase agreement through the utility grid infrastructure. In such a transaction, the electricity service and distribution fees are paid to the utility grid for overseeing the PV farm power transaction. The proposed model also considers the opportunity for D-EVCSs to participate in the provision of operating reserve and demand response ancillary services. Different case studies are evaluated for the purpose of validating the effectiveness of the proposed model.

1 January 2013 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
AAA.K. Al-Othman
A.K. Al-Othman
NANabil A. Ahmed
Nabil A. Ahmed
MAmichel alsharidah
michel alsharidah
HAHanan A. AlMekhaizim
Hanan A. AlMekhaizim

21 December 2020 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
AAAhmad S. Al-Adsani
Ahmad S. Al-Adsani
MAmichel alsharidah
michel alsharidah
OBOmid Beik
Omid Beik
The application of Hall-based BLDC motors ranges from automotive accessory components such as oil and water pumps to high speed compressors. This paper proposes a new twelve-step unsymmetrical 160o commutation strategy using a single Hall-effect sensor method for brushless DC (BLDC) motor drives. The signal from the Hall-effect sensor is used to generate a number of pseudo Hall signals via a proposed speed-position estimator. The pseudo signals are then employed to control switching logic of a voltage source inverter (VSI). The effectiveness of the single Hall sensor method is examined on the unconventional 160o strategy, and on conventional 120o, 150o and 180o strategies with promising results. The paper presents a detailed comparison of the twelve-step unsymmetrical 160o commutation strategy with six-step voltage space vector that is used in conventional 120o and 180o strategies, and twelve-step symmetrical voltage space vector that is used in 150o strategy. Simulation results are validated via experimental measurements on a laboratory set-up using a real time dSPACE control environment, a representative BLDC motor prototype, a VSI and associated control components.

3 December 2015 in Electric Power Components and Systems
Verified
Journal Article
Closed access
AAAbdulrahman K. Al-Othman
Abdulrahman K. Al-Othman
KEKhaled M. El-Naggar
Khaled M. El-Naggar
MAmichel alsharidah
michel alsharidah
A new on-line method for estimating transmission line constants of a power system is proposed in this article. The method applies a digital dynamic filter technique to perform the estimation based on minimization of residual least absolute value. The proposed technique can be used on-line to account for any dynamics changes in line constants. Synchronized phasor measurements are used to feed the dynamic filter. The synchronized samples of voltage and current waveforms, at both the receiving and sending end terminals, are used to set an over-determined system of equations. The problem is formulated as an estimation problem. Different practical case studies are presented. Eventually, the proposed discrete dynamic filtering algorithm estimates the ABCD constants and, consequently, the line parameters of both short and long lines. Effects of different factors, such as noise and unsynchronized samples, are studied. Results obtained show the reliability and accuracy of the method in estimating the transmission line parameters.

11 June 2015 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
AAA. K. Al-Othman
A. K. Al-Othman
NANabil Ahmed
Nabil Ahmed
FAF. S. Al-Fares
F. S. Al-Fares
MAmichel alsharidah
michel alsharidah

1 November 2014
Verified
Conference Paper
Closed access
MAmichel alsharidah
michel alsharidah
NANabil A. Ahmed
Nabil A. Ahmed
AAAbdulrahman K. Alothman
Abdulrahman K. Alothman
This paper introduces a novel method of is-landing detection for distributed generation networks employing negative sequence current injection measurement. The negative sequence current injection method (NSCI) is an improvement on previous impedance measurement and current injection techniques for islanding detection. The negative sequence current injection is generated in the synchronous space vector of the inverter reference current. Simulations were conducted on a distributed generator fed loads and injected negative sequence current components using PSIM software to conrm the eectiveness of the proposed method. Detailed simulations were run to demonstrate the performance of the NSCI islanding detection technique at inverters terminals.