The movement of the South Atlantic Anomaly has been observed since the end of the last century by many spacecrafts equipped with various types of radiation detectors. All satellites that have observed the drift of the South Atlantic Anomaly have been exclusively large missions with heavy payload equipment. With the recent rapid progression of CubeSats, it can be expected that the routine monitoring of the South Atlantic Anomaly will be taken over by CubeSats in the future. We present one-and-a-half years of observations of the South Atlantic Anomaly radiation field measured by a CubeSat in polar orbit with an elevation of 540 km. The position is calculated by an improved centroid method that takes into account the area of the grid. The dataset consists of eight campaigns measured at different times, each with a length of 22 orbits (~2000 min). The radiation data were combined with GPS position data. We detected westward movement at 0.33°/year and southward movement at 0.25°/year. The position of the fluence maximum featured higher scatter than the centroid position.
When primary space radiation particles enter into the atmosphere of the Earth, they generate showers of secondary radiation. The intensity of secondary radiation reaches its maximum, called the Regener–Pfotzer maximum; its exact position depends on the geomagnetic effective vertical cut-off rigidity, the phase of the solar cycle and also on the type of detected particles. In this paper, several balloon flight experiments are described focusing on the study of the latitudinal effect on the position of the Regener–Pfotzer maximum. Altitude profile of ionization in the atmosphere was measured using radiation detectors flown during several flights at locations with different effective vertical cut-off rigidities (flight HEMERA over Sweden and flights FIK-5 and FIK-6 over Czech Republic). The measured results are supplemented also with simulations using EXPACS 4.11 and the variation of obtained positions of Regener–Pfotzer maximum is discussed.
Silicon detectors such as Liulin and AIRDOS are used for cosmic radiation measurements onboard aircraft. These measurements can be used for the verification of computer programs assessing aircraft crew radiation exposure. Recently performed intercomparison flights showed large variances of absorbed doses among individual detectors and significant differences between results of silicon detectors and computer programs. In order to explain for these differences, we have developed energy calibration method that can be performed on short flights. The method is based on cross-calibration of Liulin and AIRDOS deposited energy spectra with deposited energy spectra measured by Timepix which has superior detection properties in terms of energy resolution and the detection threshold. Moreover, the portion of dose which is omitted due to low sensitivity for low-energy deposits was calculated. The resulting absorbed dose rates at two intercomparison flights show significantly improved variation of results and better agreement with modelled absorbed dose rates.
21 October 2021 in IEEE Transactions on Nuclear Science
Nowadays, silicon photomultipliers are extensively used for absorption of scintillation light in all types of scintillators in high-energy physics. Fast spread of silicon photomultipliers resulted in a rapid development of both analytical and Monte-Carlo models. Models describe the response of these silicon integrated circuits. We introduce a novel Monte-Carlo model of silicon photomultiplier with a scintillator module that enables modelling the response of silicon photomultiplier to dynamic scintillation processes. The model introduces several improvements over other models. This paper focuses on the analysis of pulse shape discrimination performance of silicon photomultiplier-based scintillation systems since such techniques are often used to discriminate between incident particles of ionizing radiation. The algorithms for pulse shape discrimination are sensitive to the shape of the pulse and silicon photomultipliers have several mechanisms that influence the shape of the output pulse, such as bandwidth of the system, the presence of fast decay components, and the recovery time of individual microcells. Some of these mechanisms are not present in a classical photomultiplier, for instance a recovery time or the fast decay component. We have analyzed the performance of three different pulse shape discrimination algorithms with three silicon photomultipliers (MicroFC-30020, MicroFC-30035 and MicroFC-30050) coupled with scintillators EJ-301 and EJ-276. Several conclusions are drawn from the analysis. The two most important ones are that optimized systems need to finetune their bandwidth and that scintillators with fast decay signals are better suited for photomultipliers with lower recovery time and vice versa. It is also shown that the classical charge comparison algorithm does not reach the performance of modern algorithms, for instance frequency gradient analysis.