Carlos Granja

Carlos Granja

Auto-generated profile, based on publicly available information

Carlos Granja

VSB - Technical University of Ostrava, Faculty of Electrical Engineering and Computer Science, 17. listopadu 2172/15, 708 00 Ostrava, Czech Republic; Advacam, U Pergamenky 12, 170 00 Prague, Czech Republic

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PSPaulina Stasica
Paulina Stasica
HNHanh Nguyen
Hanh Nguyen
CGCarlos Granja
Carlos Granja
RKRenata Kopec
Renata Kopec
LMLukas Marek
Lukas Marek
JGJan Gajewski
Jan Gajewski
Objective. Protons have advantageous dose distributions and are increasingly used in cancer therapy. At the depth of the Bragg peak range, protons produce a mixed radiation field consisting of low- and high-linear energy transfer (LET) components, the latter of which is characterized by an increased ionization density on the microscopic scale associated with increased biological effectiveness. Prediction of the yield and LET of primary and secondary charged particles at a certain depth in the patient is performed by Monte Carlo simulations but is difficult to verify experimentally. Approach. Here, the results of measurements performed with Timepix detector in the mixed radiation field produced by a therapeutic proton beam in water are presented and compared to Monte Carlo simulations. The unique capability of the detector to perform high-resolution single particle tracking and identification enhanced by artificial intelligence allowed to resolve the particle type and measure the deposited energy of each particle comprising the mixed radiation field. Based on the collected data, biologically important physics parameters, the LET of single protons and dose-averaged LET, were computed. Main results. An accuracy over 95% was achieved for proton recognition with a developed neural network model. For recognized protons, the measured LET spectra generally agree with the results of Monte Carlo simulations. The mean difference between dose-averaged LET values obtained from measurements and simulations is 17%. We observed a broad spectrum of LET values ranging from a fraction of keV μm−1 to about 10 keV μm−1 for most of the measurements performed in the mixed radiation fields. Significance. It has been demonstrated that the introduced measurement method provides experimental data for validation of LETD or LET spectra in any treatment planning system. The simplicity and accessibility of the presented methodology make it easy to be translated into a clinical routine in any proton therapy facility.

1 August 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
AKA. Kozyrev
A. Kozyrev
IMI. Mitrofanov
I. Mitrofanov
AOA. Owens
A. Owens
FQF. Quarati
F. Quarati
JBJ. Benkhoff
J. Benkhoff
SPS. Pospisil
S. Pospisil
The recent availability of large volume cerium bromide crystals raises the possibility of substantially improving gamma-ray spectrometer limiting flux sensitivities over current systems based on the lanthanum tri-halides, e.g., lanthanum bromide and lanthanum chloride, especially for remote sensing, low-level counting applications or any type of measurement characterized by poor signal to noise ratios. The Russian Space Research Institute has developed and manufactured a highly sensitive gamma-ray spectrometer for remote sensing observations of the planet Mercury from the Mercury Polar Orbiter (MPO), which forms part of ESA’s BepiColombo mission. The Flight Model (FM) gamma-ray spectrometer is based on a 3-in. single crystal of LaBr3(Ce3+) produced in a separate crystal development programme specifically for this mission. During the spectrometers development, manufacturing, and qualification phases, large crystals of CeBr3 became available in a subsequent phase of the same crystal development programme. Consequently, the Flight Spare Model (FSM) gamma-ray spectrometer was retrofitted with a 3-in. CeBr3 crystal and qualified for space. Except for the crystals, the two systems are essentially identical. In this paper, we report on a comparative assessment of the two systems, in terms of their respective spectral properties, as well as their suitability for use in planetary mission with respect to radiation tolerance and their propensity for activation. We also contrast their performance with a Ge detector representative of that flown on MESSENGER and show that: (a) both LaBr3(Ce3+) and CeBr3 provide superior detection systems over HPGe in the context of minimally resourced spacecraft and (b) CeBr3 is a more attractive system than LaBr3(Ce3+) in terms of sensitivities at lower gamma fluxes. Based on the tests, the FM has now been replaced by the FSM on the BepiColombo spacecraft. Thus, CeBr3 now forms the central gamma-ray detection element on the MPO spacecraft.

1 January 2023 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
CGC. Granja
C. Granja
RUR. Uhlar
R. Uhlar
ICI. Chuprakov
I. Chuprakov
PAP. Alexa
P. Alexa
ESE. Sansarbayar
E. Sansarbayar
JPJ. Pacik
J. Pacik
We examined the response of the pixel detector Timepix3 with silicon sensor to well-defined fast neutron fields. Part of the pixel detector silicon sensor was additionally equipped with a neutron mask of distinct converter regions. The mask consists of separate thermal and fast neutron regions using 6LiF and hydrogen (plastic) converters, respectively. Measurements were performed with mono-energetic fast neutrons produced at D-D and D-T sources from a Van de Graaff accelerator and a neutron generator, respectively. Data were collected with low background including measurements with moderator material to provide a thermalized neutron component. All the signals produced in the detector were analyzed and decomposed in terms of the spectral-tracking response of the pixel detector. The effect of the fast and thermal components of the neutron converter were determined and compared with direct interactions in the silicon sensor which are significant and can be dominant for fast neutrons. We identify and classify the neutron-induced tracks in terms of the broad-type particle-event track classes. A partial overlap is unavoidable with tracks from direct detection of other radiations in particular protons and low-energy light ions as well as X rays. This will limit the neutron-event discrimination in mixed-radiation fields. The detection response according sensor-mask region was examined and calibrated for the investigated neutron fields. The neutron detection efficiency is selectively derived for the detector particle-event classes. This approach enables to enhance the neutron-discrimination and suppress background and unwanted events. This work enables to extend the response matrix of the detector for broad-type radiations to include neutrons both fast and thermal. The results serve to enhance the sensitivity and determine the neutron component in unknown and mixed-radiation fields such as outer space and particle radiotherapy environments.

1 January 2020 in Radiation Measurements
Verified
Journal Article
Open access
ARAnatoly Rosenfeld
Anatoly Rosenfeld
SASaree Alnaghy
Saree Alnaghy
MPMarco Petasecca
Marco Petasecca
DCDean Cutajar
Dean Cutajar
MLMichael Lerch
Michael Lerch
KPKatia Parodi
Katia Parodi

1 January 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MSMarek Sommer
Marek Sommer
CGCarlos Granja
Carlos Granja
SKSatoshi Kodaira
Satoshi Kodaira
OPOndřej Ploc
Ondřej Ploc

1 November 2018 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
CGC. Granja
C. Granja
JJJ. Jakubek
J. Jakubek
MMM. Martisikova
M. Martisikova
SKSatoshi Kodaira
Satoshi Kodaira
SPS. Polansky
S. Polansky
TMT. Matlocha
T. Matlocha