Karl Ludger Radke

Mr. Karl Ludger Radke

Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, Düsseldorf, North Rhine-Westphalia, Germany
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
KRKarl Ludger Radke
Karl Ludger Radke
LWLena Wilms
Lena Wilms
Sven NebelungSven Nebelung
Sven Nebelung
DADaniel Abrar
Daniel Abrar
CSChristoph Schleich
Christoph Schleich
AMAnja Müller-Lutz
Anja Müller-Lutz
While morphologic magnetic resonance imaging (MRI) is the imaging modality of choice for the evaluation of ligamentous wrist injuries, it is merely static and incapable of diagnosing dynamic wrist instability. Based on real-time MRI and algorithm-based image post-processing in terms of convolutional neural networks (CNNs), this study aims to develop and validate an automatic technique to quantify wrist movement. A total of 56 bilateral wrists (28 healthy volunteers) were imaged during continuous and alternating maximum ulnar and radial abduction. Following CNN-based automatic segmentations of carpal bone contours, scapholunate and lunotriquetral gap widths were quantified based on dedicated algorithms and as a function of wrist position. Automatic segmentations were in excellent agreement with manual reference segmentations performed by two radiologists as indicated by Dice similarity coefficients of 0.96 ± 0.02 and consistent and unskewed Bland–Altman plots. Clinical applicability of the framework was assessed in a patient with diagnosed scapholunate ligament injury. Considerable increases in scapholunate gap widths across the range-of-motion were found. In conclusion, the combination of real-time wrist MRI and the present framework provides a powerful diagnostic tool for dynamic assessment of wrist function and, if confirmed in clinical trials, dynamic carpal instability that may elude static assessment using clinical-standard imaging modalities.

29 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
KRKarl Ludger Radke
Karl Ludger Radke
MKMatthias Kors
Matthias Kors
AMAnja Müller-Lutz
Anja Müller-Lutz
MFMiriam Frenken
Miriam Frenken
LWLena Wilms
Lena Wilms
Philipp SewerinPhilipp Sewerin
Philipp Sewerin
In recent years, much research evaluating the radiographic destruction of finger joints in patients with rheumatoid arthritis (RA) using deep learning models was conducted. Unfortunately, most previous models were not clinically applicable due to the small object regions as well as the close spatial relationship. In recent years, a new network structure called RetinaNets, in combination with the focal loss function, proved reliable for detecting even small objects. Therefore, the study aimed to increase the recognition performance to a clinically valuable level by proposing an innovative approach with adaptive changes in intersection over union (IoU) values during training of Retina Networks using the focal loss error function. To this end, the erosion score was determined using the Sharp van der Heijde (SvH) metric on 300 conventional radiographs from 119 patients with RA. Subsequently, a standard RetinaNet with different IoU values as well as adaptively modified IoU values were trained and compared in terms of accuracy, mean average accuracy (mAP), and IoU. With the proposed approach of adaptive IoU values during training, erosion detection accuracy could be improved to 94% and an mAP of 0.81 ± 0.18. In contrast Retina networks with static IoU values achieved only an accuracy of 80% and an mAP of 0.43 ± 0.24. Thus, adaptive adjustment of IoU values during training is a simple and effective method to increase the recognition accuracy of small objects such as finger and wrist joints.

27 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
KRKarl Ludger Radke
Karl Ludger Radke
BKBenedikt Kamp
Benedikt Kamp
VAVibhu Adriaenssens
Vibhu Adriaenssens
JSJulia Stabinska
Julia Stabinska
PGPatrik Gallinnis
Patrik Gallinnis
AMAnja Müller-Lutz
Anja Müller-Lutz
Chemical Exchange Saturation Transfer (CEST) magnetic resonance imaging (MRI) provides a novel method for analyzing biomolecule concentrations in tissues without exogenous contrast agents. Despite its potential, achieving a high signal-to-noise ratio (SNR) is imperative for detecting small CEST effects. Traditional metrics such as Magnetization Transfer Ratio Asymmetry (MTRasym) and Lorentzian analyses are vulnerable to image noise, hampering their precision in quantitative concentration estimations. Recent noise-reduction algorithms like principal component analysis (PCA), nonlocal mean filtering (NLM), and block matching combined with 3D filtering (BM3D) have shown promise, as there is a burgeoning interest in the utilization of neural networks (NNs), particularly autoencoders, for imaging denoising. This study uses the Bloch–McConnell equations, which allow for the synthetic generation of CEST images and explores NNs efficacy in denoising these images. Using synthetically generated phantoms, autoencoders were created, and their performance was compared with traditional denoising methods using various datasets. The results underscored the superior performance of NNs, notably the ResUNet architectures, in noise identification and abatement compared to analytical approaches across a wide noise gamut. This superiority was particularly pronounced at elevated noise intensities in the in vitro data. Notably, the neural architectures significantly improved the PSNR values, achieving up to 35.0, while some traditional methods struggled, especially in low-noise reduction scenarios. However, the application to the in vivo data presented challenges due to varying noise profiles. This study accentuates the potential of NNs as robust denoising tools, but their translation to clinical settings warrants further investigation.

11 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
MFMiriam Frenken
Miriam Frenken
GRGesa Rübsam
Gesa Rübsam
AMAlexander Mewes
Alexander Mewes
KRKarl Ludger Radke
Karl Ludger Radke
LLLien Li
Lien Li
Philipp SewerinPhilipp Sewerin
Philipp Sewerin
Currently, clinical indications for the application of gadolinium-based contrast agents (GBCA) in magnetic resonance imaging (MRI) are increasingly being questioned. Consequently, this study aimed to evaluate the additional diagnostic value of contrast enhancement in MRI of the hand in patients with rheumatoid arthritis (RA). Thirty-one patients with RA (mean age, 50 ± 14 years (range, 18–72 years)) underwent morphologic MRI scans on a clinical 3 T scanner. MRI studies were analyzed based on (1) the Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) and (2) the GBCA-free RAMRIS version, termed RAMRIS Sine-Gadolinium-For-Experts (RAMRIS-SAFE), in which synovitis and tenosynovitis were assessed using the short-tau inversion-recovery sequence instead of the post-contrast T1-weighted sequence. The synovitis subscores in terms of Spearman’s ρ, as based on RAMRIS and RAMRIS-SAFE, were almost perfect (ρ = 0.937; p < 0.001), while the tenosynovitis subscores were less strongly correlated (ρ = 0.380 p = 0.035). Correlation between the total RAMRIS and RAMRIS-SAFE was also almost perfect (ρ = 0.976; p < 0.001). Inter-rater reliability in terms of Cohen’s κ was high (0.963 ≤ κ ≤ 0.925). In conclusion, RAMRIS-SAFE as the GBCA-free version of the well-established RAMRIS is a patient-friendly and resource-efficient alternative for assessing disease-related joint changes in RA. As patients with RA are subject to repetitive GBCA applications, non-contrast imaging protocols should be considered.

26 February 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
MFMiriam Frenken
Miriam Frenken
Sven NebelungSven Nebelung
Sven Nebelung
CSChristoph Schleich
Christoph Schleich
AMAnja Müller-Lutz
Anja Müller-Lutz
KRKarl Ludger Radke
Karl Ludger Radke
DADaniel Abrar
Daniel Abrar
Using glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) magnetic resonance imaging (MRI), this study comparatively evaluated the GAG contents of lumbar intervertebral disks (IVDs) of patients with non-specific low back pain (nsLBP), radiculopathy, and asymptomatic volunteers to elucidate the association of clinical manifestation and compositional correlate. A total of 18 patients (mean age 57.5 ± 22.5 years) with radiculopathy, 16 age-matched patients with chronic nsLBP and 20 age-matched volunteers underwent standard morphologic and compositional gagCEST MRI on a 3T scanner. In all cohorts, GAG contents of lumbar IVDs were determined using gagCEST MRI. An assessment of morphologic IVD degeneration based on the Pfirrmann classification and T2-weighted sequences served as a reference. A linear mixed model adjusted for multiple confounders was used for statistical evaluation. IVDs of patients with nsLBP showed lower gagCEST values than those of volunteers (nsLBP: 1.3% [99% confidence intervals (CI): 1.0; 1.6] vs. volunteers: 1.9% [99% CI: 1.6; 2.2]). Yet, IVDs of patients with radiculopathy (1.8% [99% CI: 1.4; 2.1]) were not different from patients with nsLBP or volunteers. In patients with radiculopathy, IVDs directly adjacent to IVD extrusions demonstrated lower gagCEST values than distant IVDs (adjacent: 0.9% [99% CI: 0.3; 1.5], distant: 2.1% [99% CI: 1.7; 2.5]). Advanced GAG depletion in nsLBP and directly adjacent to IVD extrusions in radiculopathy indicates close interrelatedness of clinical pathology and compositional degeneration.

Verified
Journal Article
Open access
PDF file
BKBenedikt Kamp
Benedikt Kamp
MFMiriam Frenken
Miriam Frenken
LKLena Klein-Schmeink
Lena Klein-Schmeink
ANArmin M. Nagel
Armin M. Nagel
LWLena Wilms
Lena Wilms
AMAnja Müller-Lutz
Anja Müller-Lutz
Sodium magnetic resonance imaging (MRI) can be used to evaluate the change in the proteoglycan content in Achilles tendons (ATs) of patients with different AT pathologies by measuring the 23Na signal-to-noise ratio (SNR). As 23Na SNR alone is difficult to compare between different studies, because of the high influence of hardware configurations and sequence settings on the SNR, we further set out to measure the apparent tissue sodium content (aTSC) in the AT as a better comparable parameter. Ten healthy controls and one patient with tendinopathy in the AT were examined using a clinical 3 Tesla (T) MRI scanner in conjunction with a dual tuned 1H/23Na surface coil to measure 23Na SNR and aTSC in their ATs. 23Na T1 and T2* of the AT were also measured for three controls to correct for different relaxation behavior. The results were as follows: 23Na SNR = 11.7 ± 2.2, aTSC = 82.2 ± 13.9 mM, 23Na T1 = 20.4 ± 2.4 ms, 23Na T2s* = 1.4 ± 0.4 ms, and 23Na T2l* = 13.9 ± 0.8 ms for the whole AT of healthy controls with significant regional differences. These are the first reported aTSCs and 23Na relaxation times for the AT using sodium MRI and may serve for future comparability in different studies regarding examinations of diseased ATs with sodium MRI.