Simone Borri

Dr. Simone Borri

CNR-INO – Istituto Nazionale di Ottica, Largo E. Fermi 6, 50125 Firenze, FI, Italy
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2011 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
IGI. Galli
I. Galli
SBSaverio Bartalini
Saverio Bartalini
Simone BorriSimone Borri
Simone Borri
PPPablo Cancio Pastor
Pablo Cancio Pastor
Davide MazzottiDavide Mazzotti
Davide Mazzotti
GGG. Giusfredi
G. Giusfredi
Radiocarbon (C14) concentrations at a 43 parts-per-quadrillion level are measured by using saturated-absorption cavity ringdown spectroscopy by exciting radiocarbon-dioxide (C14O216) molecules at the 4.5  μm wavelength. The ultimate sensitivity limits of molecular trace gas sensing are pushed down to attobar pressures using a comb-assisted absorption spectroscopy setup. Such a result represents the lowest pressure ever detected for a gas of simple molecules. The unique sensitivity, the wide dynamic range, the compactness, and the relatively low cost of this table-top setup open new perspectives for C14-tracing applications, such as radiocarbon dating, biomedicine, or environmental and earth sciences. The detection of other very rare molecules can be pursued as well thanks to the wide and continuous mid-IR spectral coverage of the described setup.

26 February 2010 in Physical Review Letters
Verified
Journal Article
Closed access
SBSaverio Bartalini
Saverio Bartalini
Simone BorriSimone Borri
Simone Borri
PCP. Cancio
P. Cancio
ACAntonio Castrillo
Antonio Castrillo
IGI. Galli
I. Galli
PNP. De Natale
P. De Natale
A comprehensive investigation of the frequency-noise spectral density of a free-running midinfrared quantum-cascade laser is presented for the first time. It provides direct evidence of the leveling of this noise down to a white-noise plateau, corresponding to an intrinsic linewidth of a few hundred hertz. The experiment is in agreement with the most recent theory on the fundamental mechanism of line broadening in quantum-cascade lasers, which provides a new insight into the Schawlow-Townes formula and predicts a narrowing beyond the limit set by the radiative lifetime of the upper level.

23 October 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
Simone BorriSimone Borri
Simone Borri
Gaetano ScamarcioGaetano Scamarcio
Gaetano Scamarcio
BBBruce E. Bernacki
Bruce E. Bernacki
JKJason Kriesel
Jason Kriesel
A sensitive spectroscopic sensor based on a hollow-core fiber-coupled quantum cascade laser (QCL) emitting at 10.54 μm and quartz enhanced photoacoustic spectroscopy (QEPAS) technique is reported. The design and realization of mid-IR fiber and coupler optics has ensured single-mode QCL beam delivery to the QEPAS sensor. The collimation optics was designed to produce a laser beam of significantly reduced beam size and waist so as to prevent illumination of the quartz tuning fork and microresonator tubes. SF6 was selected as the target gas. A minimum detection sensitivity of 50 parts per trillion in 1 s was achieved with a QCL power of 18 mW, corresponding to a normalized noise-equivalent absorption of 2.7×10−10  W·cm−1/Hz1/2.

19 March 2010 in Physical Review Letters
Verified
Journal Article
Closed access
GGG. Giusfredi
G. Giusfredi
SBSaverio Bartalini
Saverio Bartalini
Simone BorriSimone Borri
Simone Borri
PCP. Cancio
P. Cancio
IGI. Galli
I. Galli
PNP. De Natale
P. De Natale
We report on a novel approach to cavity ring-down spectroscopy with the sample gas in saturated-absorption regime. This technique allows us to decouple and simultaneously retrieve the empty-cavity background and absorption signal, by means of a theoretical model that we developed and tested. The high sensitivity and frequency precision for spectroscopic applications are exploited to measure, for the first time, the hyperfine structure of an excited vibrational state of O17C12O16 in natural abundance with an accuracy of a few parts in 10-11.

3 March 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
Simone BorriSimone Borri
Simone Borri
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
IGI. Galli
I. Galli
Davide MazzottiDavide Mazzotti
Davide Mazzotti
GGG. Giusfredi
G. Giusfredi
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
We report on a spectroscopic technique named intracavity quartz-enhanced photoacoustic spectroscopy (I-QEPAS) employed for sensitive trace-gas detection in the mid-infrared spectral region. It is based on a combination of QEPAS with a buildup optical cavity. The sensor includes a distributed feedback quantum cascade laser emitting at 4.33 μm. We achieved a laser optical power buildup factor of ∼500, which corresponds to an intracavity laser power of ∼0.75 W. CO2 has been selected as the target molecule for the I-QEPAS demonstration. We achieved a detection sensitivity of 300 parts per trillion for 4 s integration time, corresponding to a noise equivalent absorption coefficient of 1.4 × 10−8 cm−1 and a normalized noise-equivalent absorption of 3.2 × 10−10 W cm−1 Hz−1/2.

8 July 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Simone BorriSimone Borri
Simone Borri
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
HBH. E. Beere
H. E. Beere
DRD. A. Ritchie
D. A. Ritchie
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
A quartz enhanced photo-acoustic sensor employing a single-mode quantum cascade laser emitting at 3.93 Terahertz (THz) is reported. A custom tuning fork with a 1 mm spatial separation between the prongs allows the focusing of the THz laser beam between them, while preventing the prongs illumination. A methanol transition with line-strength of 4.28 × 10−21 cm has been selected as target spectroscopic line. At a laser optical power of ∼ 40 μW, we reach a sensitivity of 7 parts per million in 4s integration time, corresponding to a 1σ normalized noise-equivalent absorption of 2 × 10−10 cm−1W/Hz½.