Matthew PENG

Dr. Matthew PENG


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
TAT. Al-Anezi
T. Al-Anezi
BKB. Khambay
B. Khambay
MPMatthew PENG
Matthew PENG
EOE. O’leary
E. O’leary
Xiangyang JuXiangyang Ju
Xiangyang Ju
Ashraf AyoubAshraf Ayoub
Ashraf Ayoub

1 November 2013 in European Journal of Radiology
Verified
Journal Article
Closed access
XLXinchun Li
Xinchun Li
JCJingcong Chen
Jingcong Chen
GHGoubin Hong
Goubin Hong
CSCongpeng Sun
Congpeng Sun
XWXiaomen Wu
Xiaomen Wu
GZGuangqiao Zeng
Guangqiao Zeng

1 September 2020 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
MPMatthew PENG
Matthew PENG
HXHongWen Xu
HongWen Xu
HCHai-Yan Chen
Hai-Yan Chen
ZLZe Lin
Ze Lin
XLXinXu Li
XinXu Li
YGYueMing Guo
YueMing Guo

1 January 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
MPMatthew PENG
Matthew PENG
XCXiongWei Cao
XiongWei Cao
HCHai-Yan Chen
Hai-Yan Chen
YHYong Hu
Yong Hu
XLXinXu Li
XinXu Li
BBBo Bai
Bo Bai

11 July 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
MPMatthew PENG
Matthew PENG
HCHai-Yan Chen
Hai-Yan Chen
YHYong Hu
Yong Hu
Xiangyang JuXiangyang Ju
Xiangyang Ju
BBBo Bai
Bo Bai
There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically. Ten specimens of femurs scanned by CT were input onto Mimics to rebuild 3D models; their *stl format dataset were imported into Geomagic-Studio for simulative osteotomy; the generated *.igs dataset were interacted by UG to fit solid models; the prosthesis were obtained by the same way from patients, and bored by punching bears designed by Pro-E virtually; cements between femora and prosthesis were extracted by deleting prosthesis; in HyperMesh, all compartments were assembled onto four artificial joint style as: (a) cemented long-stem prosthesis; (b) porous long-stem prosthesis; (c) cemented short-stem prosthesis; (d) porous short-stem prosthesis. Then, these numerical models of Finite Element Analysis were exported to AnSys for numerical solution. Observed whatever from femur or prosthesis or combinational femora-prostheses, “Kruskal-Wallis” value p > 0.05 demonstrates that displacement of (d) ≈ (a) ≈ (b) ≈ (c) shows nothing different significantly by comparison with 600 N load. If stresses are tested upon prosthesis, (d) ≈ (a) ≈ (b) ≈ (c) is also displayed; if upon femora, (d) ≈ (a) ≈ (b) < (c) is suggested; if upon integral joint, (d) ≈ (a) < (b) < (c) is presented. Mechanically, these four sorts of artificial joint replacement are stabilized in quantity. Cemented short-stem prostheses present the biggest stress, while porous short-stem & cemented long-stem designs are equivalently better than porous long-stem prostheses and alternatives for femoral-head replacement. The preferred design of those two depends on clinical conditions. The cemented long-stem is favorable for inactive elders with osteoporosis, and porously punched cementless short-stem design is suitable for patients with osteoporosis, while the porously punched cementless short-stem is favorable for those with a cement allergy. Clinically, the strength of this study is to enable preoperative strategy to provide acute correction and decrease procedure time.

31 March 2012 in European Journal of Radiology
Verified
Journal Article
Closed access
PDF file
MPMatthew PENG
Matthew PENG
Xiangyang JuXiangyang Ju
Xiangyang Ju
BKBalvinder S. Khambay
Balvinder S. Khambay
Ashraf AyoubAshraf Ayoub
Ashraf Ayoub
CCChin-Tu Chen
Chin-Tu Chen
BBBo Bai
Bo Bai