In recent years, civil engineering has increasingly focused on utilizing fiber-reinforced polymers (FRPs) to retrofit and strengthen reinforced concrete (RC) structures. This paper explores advancements in FRP retrofitting techniques, with a particular focus on their application to beam–column joints in RC structures. The introduction outlines the evolution of FRP materials and their optimization for seismic retrofitting applications. A critical review of existing research highlights the effectiveness of FRP reinforcement in improving seismic resilience. The study examines three distinct cases from post-earthquake assessments in Albania, addressing the impact of poor concrete quality and inadequate detailing on structural performance. To capture the behavior of FRP-strengthened RC structures comprehensively, nonlinear finite element analysis (NLFEA) was employed for localized analysis to observe the influence of FRP strengthening on critical joints, while finite element modeling (FEM) was used for global analysis to demonstrate the behavior at the structural level. The combined approach evaluates the effectiveness of FRP reinforcement in mitigating vulnerabilities, such as shear deficiencies and brittle failure modes, across varying scenarios of material quality and detailing. Key findings indicate that FRP retrofitting strategies result in a 25% increase in peak shear force and a 20% improvement in displacement capacity, showcasing enhanced ductility and seismic resilience. The finite element analysis demonstrated strong prediction accuracy, with error margins below 5% when compared to experimental results. These results emphasize the critical role of tailored FRP retrofitting strategies in enhancing seismic resilience, offering valuable insights for future retrofitting practices in seismic-prone regions.
Glued laminated timber (glulam) is increasingly adopted as a sustainable structural material; however, its performance under bending can be limited by brittle tensile failures and variability caused by natural defects. This study examines the flexural behavior of glulam beams strengthened with externally bonded carbon fiber reinforced polymer (CFRP) sheets. A four-point bending experimental program was carried out on glulam beams with varying CFRP bonded lengths, including unreinforced control beams. The results demonstrate that CFRP reinforcement enhanced load–carrying capacity by up to 48%, increased stiffness, and shifted failure modes from brittle tension–side ruptures to more favorable compression–controlled mechanisms. A nonlinear finite element (FE) model was developed using DIANA software 10.5 to simulate the structural response of both unreinforced and CFRP–strengthened beams. The numerical model accurately reproduced the experimental load–deflection behavior, stress redistribution, and failure trends, with deviations in ultimate load prediction generally within ±16% across all reinforcement configurations. The simulations further revealed the critical influence of CFRP bonded length on stress transfer efficiency and failure mode transition, mimicking experimental observations. By integrating experimental findings with numerical simulations and simplified analytical predictions, the study demonstrates that reinforcement length and bond activation govern the effectiveness of CFRP strengthening. The proposed combined methodology provides a reliable framework for evaluating and designing CFRP strengthened glulam beams.
Macro‐models based on equivalent diagonal struts are the only practical option for the structural‐scale analysis of masonry‐infilled reinforced concrete (RC) frames, but their parameters, above all the effective strut width, are empirical, were calibrated almost exclusively on solid units and cannot be measured directly; experimental calibration is scarce because each point requires a full‐scale frame test. This article proposes simplified micro‐modelling (SMM) of perforated block masonry as the technique that supplies them. Perforated clay blocks are replaced by equivalent solid units expanded by the mortar thickness, the joints are reduced to zero‐thickness cohesive interfaces with tensile and shear yield criteria, and the continuum is governed by a concrete damage plasticity (CDP) law. Replacing the perforated unit removes the constraint its thin internal shells impose on the explicit time increment, while the expanded‐unit properties come from small prism and wall‐panel tests or from Eurocode 6 expressions and are used without user subroutines. The technique reproduces the capacity, stiffness and observed failure mechanisms of two quasi‐static tests on perforated clay block infilled RC frames to within 10%–12%; a third was reproduced with the same technique in earlier work. The validated model is then the reference from which an equivalent‐strut macro‐model is calibrated: three parallel compression‐only struts on a fibre frame in OpenSees. On Specimen 13 the envelope is identified from the measured backbone and the model returns the peak base shear to within 0.6% with a whole‐curve error of 2.1%; in every validation case the envelope is generated from the masonry properties and one quantity only is fitted, the dimensionless strut width. Calibrated on a single one‐bay frame, that parameter transfers unchanged to two‐ and three‐bay frames with a mean absolute error of 2.5% in peak base shear and a maximum of 3.1%, verified on complete curves rather than peaks, and is conservative by 8%–16% when carried to six‐storey frames. The calibrated width increases with the quality of the masonry, from 0.193 to 0.294 of the panel diagonal, whereas a width defined through a stiffness parameter alone falls from 0.152 to 0.129 over the same range; the three levels examined vary strength, modulus and strains together and cannot separate them. Column shear links following expression A.12 of EN 1998‐3 show the configuration with the smallest drift to be the one whose columns fail, so for frames of these proportions the governing limit state is local; a sensitivity study over seven distributions of the infill thrust among the struts, and over ±20% on every calibrated quantity, leaves that conclusion standing and identifies the strut width as the one quantity it depends on. The reduced‐scale study then delimits what a similitude comparison can demonstrate: a strut macro‐model contains no length scale and satisfies the similarity relationships identically, whereas the micro‐model departs from them by up to 4.5%, and that departure is the measurable size effect.