Samuel Stevens

Mr. Samuel Stevens

University of Edinburgh
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2020 in Fire Technology
Verified
Journal Article
Open access
PDF file
Antonio CicioneAntonio Cicione
Antonio Cicione
RWRichard Walls
Richard Walls
ZSZara Sander
Zara Sander
NQNatalia Flores Quiroz
Natalia Flores Quiroz
VNVignesh Narayanan
Vignesh Narayanan
DRDAvid Rush
DAvid Rush
Globally, the number of informal settlement dwellings are increasing rapidly; these areas are often associated with numerous large fires. Unfortunately, until recently, very little research has been focused on informal settlement fire issues leaving any attempts to improve their fire safety lacking the evidence base to support effective-decision making. However, over the past 4 years, a limited number of researchers have looked at better understanding these fires through full-scale experimentation and numerical modelling; starting to provide the necessary evidence base and future research directions. It is with this background in mind that this paper seeks to provide a more fundamental understanding of the effect of dwelling separation distance on informal settlement fire spread based on full-scale experiments and analytical equations. In this paper two full-scale experiments were conducted. Both experiments consisted of multiple dwellings, with the main difference between the experiments being the separation distance. Fire spread times, heat release rates, door and window flow velocities, ceiling temperatures and incident heat fluxes were recorded and are reported for both experiments. Theoretical neutral planes are derived and compared to the experimental neutral planes, which show relatively good correlation. The paper continues by calculating the expected incident radiation and time-to-ignition, using the flux-time product method, of the two fire scenarios (i.e., the two experiments) through means of analytical equations, and these findings are compared to the experimental results. Through configuration factors, the paper shows the effect of separation distance, dwelling height and dwelling length on the times-to-ignition, where it is clear that the heat flux received by an adjacent dwelling decrease approximately exponentially as the distance between dwellings increases, and consequently, the time-to-ignition increases exponentially as the separation distance between dwellings increases.

8 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Mohamed BeshirMohamed Beshir
Mohamed Beshir
Karim Omar OmarKarim Omar Omar
Karim Omar Omar
FCFelipe Roman Centeno
Felipe Roman Centeno
SSSamuel Stevens
Samuel Stevens
LGLesley Gibson
Lesley Gibson
DRDAvid Rush
DAvid Rush
According to recent UN reports, it is estimated that more than one billion people live in informal settlements globally, exposing them to a large potential fire risk. In previous research, it was found that the main fire spread mechanism between dwellings is the external flaming (plume) and radiative heat fluxes from the vertical openings at the dwelling of origin to the surroundings. In this paper, an experimental and numerical study was conducted to quantify the effect of adding horizontal roof openings to the design of informal settlement dwellings to reduce the fire spread risk by decreasing the length of flames and radiation from the external plumes at the vertical openings. In total, 19 quarter scale ISO-9705 compartment fire experiments were conducted using an identical fuel load (80 MJ/m2) of polypropylene and were used to validate a physical computational fluid dynamics model for future studies. Five different total horizontal openings areas (0.0025, 0.01, 0.04, 0.09, and 0.16 m2) were investigated using two horizontal openings designs: (1) four square openings at the four corners of the compartment and (2) one slot cut at the middle of the compartment. It was found that adding horizontal openings decreased the average heat flux measured at the door by up to 65% and 69% for corner and slot cases, respectively. Heat flux reductions were achieved at opening areas as low as 0.01 m2 for slot cases, whereas reductions were only achieved at areas of at least 0.09 m2 for corner cases. The Computational Fluid Dynamics (CFD) model was validated using the experimental results. It successfully captured the main fire dynamics within the compartment in addition to the values of the external radiative heat flux. Further, a new empirical ventilation factor was generated to describe the flow field through both openings configurations which showed strong coupling with the inlet mass of fresh air to the compartment.

26 April 2025 in International Journal of Disaster Risk Reduction
Verified
Journal Article
Open access
SSSamuel Stevens
Samuel Stevens
DRDavid Rush
David Rush

4 March 2026 in Fire Safety Journal
Verified
Journal Article
Open access
SSSamuel Stevens
Samuel Stevens
WJWilliam Jarrett
William Jarrett
TATim Aspinall
Tim Aspinall
KDKevin Denham
Kevin Denham
EEEmmajane Erskine
Emmajane Erskine
RHRory M. Hadden
Rory M. Hadden