Dimitrios Zeugolis

Prof. Dimitrios Zeugolis

University of Ioannina, Ioánnina, Ípeiros, Greece
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
ASAnna Sorushanova
Anna Sorushanova
LDLuis M. Delgado
Luis M. Delgado
ZWZhuning Wu
Zhuning Wu
NSNaledi Shologu
Naledi Shologu
AKAniket Kshirsagar
Aniket Kshirsagar
Dimitrios ZeugolisDimitrios Zeugolis
Dimitrios Zeugolis

1 May 2008 in Biomaterials
Verified
Journal Article
Open access
Dimitrios ZeugolisDimitrios Zeugolis
Dimitrios Zeugolis
SKShih T. Khew
Shih T. Khew
EYElijah S.Y. Yew
Elijah S.Y. Yew
AEAndrew K. Ekaputra
Andrew K. Ekaputra
YTYen Wah Tong
Yen Wah Tong
Michael RaghunathMichael Raghunath
Michael Raghunath
Scaffolds manufactured from biological materials promise better clinical functionality, providing that characteristic features are preserved. Collagen, a prominent biopolymer, is used extensively for tissue engineering applications, because its signature biological and physico-chemical properties are retained in in vitro preparations. We show here for the first time that the very properties that have established collagen as the leading natural biomaterial are lost when it is electro-spun into nano-fibres out of fluoroalcohols such as 1,1,1,3,3,3-hexafluoro-2-propanol or 2,2,2-trifluoroethanol. We further identify the use of fluoroalcohols as the major culprit in the process. The resultant nano-scaffolds lack the unique ultra-structural axial periodicity that confirms quarter-staggered supramolecular assemblies and the capacity to generate second harmonic signals, representing the typical crystalline triple-helical structure. They were also characterised by low denaturation temperatures, similar to those obtained from gelatin preparations (p>0.05). Likewise, circular dichroism spectra revealed extensive denaturation of the electro-spun collagen. Using pepsin digestion in combination with quantitative SDS-PAGE, we corroborate great losses of up to 99% of triple-helical collagen. In conclusion, electro-spinning of collagen out of fluoroalcohols effectively denatures this biopolymer, and thus appears to defeat its purpose, namely to create biomimetic scaffolds emulating the collagen structure and function of the extracellular matrix.

7 November 2019 in Molecules
Verified
Journal Article
Open access
PDF file
ALArely León
Arely León
AMAlejandro Morales-Peñaloza
Alejandro Morales-Peñaloza
VMVíctor-Manuel Martínez-Juárez
Víctor-Manuel Martínez-Juárez
AVApolonio Vargas-Torres
Apolonio Vargas-Torres
Dimitrios ZeugolisDimitrios Zeugolis
Dimitrios Zeugolis
Gabriel Aguirre-ÁlvarezGabriel Aguirre-Álvarez
Gabriel Aguirre-Álvarez
Hydrolyzed collagen (HC) is a group of peptides with low molecular weight (3–6 KDa) that can be obtained by enzymatic action in acid or alkaline media at a specific incubation temperature. HC can be extracted from different sources such as bovine or porcine. These sources have presented health limitations in the last years. Recently research has shown good properties of the HC found in skin, scale, and bones from marine sources. Type and source of extraction are the main factors that affect HC properties, such as molecular weight of the peptide chain, solubility, and functional activity. HC is widely used in several industries including food, pharmaceutical, cosmetic, biomedical, and leather industries. The present review presents the different types of HC, sources of extraction, and their applications as a biomaterial.

16 November 2011 in Journal of The Royal Society Interface
Verified
Journal Article
Closed access
PDF file
WDW. Daly
W. Daly
LYL. Yao
L. Yao
Dimitrios ZeugolisDimitrios Zeugolis
Dimitrios Zeugolis
AWA. Windebank
A. Windebank
Abhay PanditAbhay Pandit
Abhay Pandit
Microsurgical techniques for the treatment of large peripheral nerve injuries (such as the gold standard autograft) and its main clinically approved alternative—hollow nerve guidance conduits (NGCs)—have a number of limitations that need to be addressed. NGCs, in particular, are limited to treating a relatively short nerve gap (4 cm in length) and are often associated with poor functional recovery. Recent advances in biomaterials and tissue engineering approaches are seeking to overcome the limitations associated with these treatment methods. This review critically discusses the advances in biomaterial-based NGCs, their limitations and where future improvements may be required. Recent developments include the incorporation of topographical guidance features and/or intraluminal structures, which attempt to guide Schwann cell (SC) migration and axonal regrowth towards their distal targets. The use of such strategies requires consideration of the size and distribution of these topographical features, as well as a suitable surface for cell–material interactions. Likewise, cellular and molecular-based therapies are being considered for the creation of a more conductive nerve microenvironment. For example, hurdles associated with the short half-lives and low stability of molecular therapies are being surmounted through the use of controlled delivery systems. Similarly, cells (SCs, stem cells and genetically modified cells) are being delivered with biomaterial matrices in attempts to control their dispersion and to facilitate their incorporation within the host regeneration process. Despite recent advances in peripheral nerve repair, there are a number of key factors that need to be considered in order for these new technologies to reach the clinic.

1 April 2015 in Advanced Drug Delivery Reviews
Verified
Journal Article
Closed access
MFMarc A. Fernandez-Yague
Marc A. Fernandez-Yague
SASunny Akogwu Abbah
Sunny Akogwu Abbah
LMLaoise McNamara
Laoise McNamara
Dimitrios ZeugolisDimitrios Zeugolis
Dimitrios Zeugolis
Abhay PanditAbhay Pandit
Abhay Pandit
MBManus J. Biggs
Manus J. Biggs

1 June 2015 in Tissue Engineering Part B: Reviews
Verified
Journal Article
Closed access
LDLuis M. Delgado
Luis M. Delgado
YBYves Bayon
Yves Bayon
Abhay PanditAbhay Pandit
Abhay Pandit
Dimitrios ZeugolisDimitrios Zeugolis
Dimitrios Zeugolis
Collagen-based devices, in various physical conformations, are extensively used for tissue engineering and regenerative medicine applications. Given that the natural cross-linking pathway of collagen does not occur in vitro, chemical, physical, and biological cross-linking methods have been assessed over the years to control mechanical stability, degradation rate, and immunogenicity of the device upon implantation. Although in vitro data demonstrate that mechanical properties and degradation rate can be accurately controlled as a function of the cross-linking method utilized, preclinical and clinical data indicate that cross-linking methods employed may have adverse effects on host response, especially when potent cross-linking methods are employed. Experimental data suggest that more suitable cross-linking methods should be developed to achieve a balance between stability and functional remodeling.