Wang Xi

Dr. Wang Xi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2022 in Energy
Verified
Journal Article
Closed access
BXBin Xi
Bin Xi
CWChuan Wang
Chuan Wang
WXWang Xi
Wang Xi
YLYang Liu
Yang Liu
HWHui Wang
Hui Wang
Yang YangYang Yang
Yang Yang

1 November 2020 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
PDF file
XDXiao-Xuan Du
Xiao-Xuan Du
MLMartin F. Lambert
Martin F. Lambert
LCLei Chen
Lei Chen
Eric HuEric Hu
Eric Hu
WXWang Xi
Wang Xi
The purpose of this paper is to present a technique for burst detection, localization, and cross-sectional area quantification based on the damping of fluid transients. The Fourier components of the transient signal are damped differently due to the presence of the burst and the unsteady friction it causes. An unsteady friction water hammer (UFWH) model has been developed and validated to determine the unsteady friction damping. The burst damping can then be calculated, and this both indicates the presence of the burst and contains information about the burst location and the associated cross-sectional area. The corresponding numerical studies and experimental results are presented in this paper. By applying the technique outlined in this paper, the errors of the resultant burst location from the numerical and experimental analyses are 1%–1.5% and 1.57%–4.05% , respectively.

1 January 2021 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
WXWang Xi
Wang Xi
WLWeigang Lu
Weigang Lu
CWChuan Wang
Chuan Wang
BXBo Xu
Bo Xu
The layout of the pump station is easily affected by topography, site, and other factors, resulting in poor inlet flow patterns in the forebay, which seriously affect the normal operation of the pump station. To optimize its inlet flow pattern, the size of the hollow rectification sill has been continuously improved through physical model tests to meet the requirements of the required pump station inlet flow field. In this paper, particle swarm optimization (PSO) was combined with the Gaussian process (GP) to establish a particle swarm‐Gaussian process (PSO‐GP) model to predict the velocity uniformity of the inlet sump of pump stations with different hole‐to‐height ratios, hole‐to‐width ratios, upper‐to‐lower sill length ratios, and sill height‐to‐water table ratios. Finally, the hollow rectification sill with the optimal size was obtained and tested in the physical model to compare the rectification effect with other sizes of hollow sills. The results show that the algorithm model can help the traditional physical experiment quickly predict the velocity uniformity of the inlet sump of the pump station. Through the optimization by the PSO‐GP algorithm, we can get the optimal size of the hollow rectification sill. Its hole‐to‐height ratio is 0.62, its hole‐to‐width ratio is 0.37, upper‐to‐lower sill length ratio is 0.63, and sill height‐to‐water table ratio is 0.23. It shows that this method is practical in the optimization design of the hollow rectification sill and provides a new method for the optimization of the flow field in the forebay of the pump station.

Verified
Journal Article
Open access
PDF file
TJTao Jiang
Tao Jiang
WLWeigang Lu
Weigang Lu
LLLinguang LU
Linguang LU
LXLei XU
Lei XU
WXWang Xi
Wang Xi
DJDongtao Ji
Dongtao Ji
The axial-flow pump system has been widely applied to coastal drainage pump stations, but the hydraulic performance optimization based on the contraction angles of the inlet passage has not been studied. This paper combined the computational fluid dynamics (CFD) method, machine learning (ML) algorithms and genetic algorithm (GA) to find the optimal contraction angles of the inlet passage. The 125 sets of comprehensive objective function were obtained by the CFD method. Three contraction angles and comprehensive objective function values were regressed by three ML algorithms. After hyperparameter optimization, the Gaussian process regression (GPR) model had the highest R2 = 0.958 in the test set and had the strongest generalization ability among the three models. The impact degree of the three contraction angles on the objective function of the GPR model was investigated by the Sobol sensitivity analysis method; the results indicated that the order of impact degree from high to low was θ3>θ2>θ1. The optimal objective function values of the GPR model and corresponding contraction angles were searched through GA; the maximum objective function value was 0.963 and corresponding contraction angles were θ1=13.34°, θ2=28.36° and θ3=3.64°, respectively. The results of this study can provide reference for the optimization of inlet passages in coastal drainage pump systems.

Verified
Journal Article
Open access
PDF file
JLJianfeng Liu
Jianfeng Liu
WXWang Xi
Wang Xi
WLWeigang Lu
Weigang Lu
Influenced by the clearance flow between stator and rotor, the operational performance and hydraulic performance of full cross-flow pump units are often worse than that of semi-cross-flow pumps. In order to explore the influence mechanism of clearance structural parameters on clearance flow and provide a reliable scientific support for the improvement of both external and internal characteristics of full cross-flow pump units, firstly, the optimization of the stator–rotor clearance structure was studied as research entry point and the radial inlet and outlet clearance width were taken to set up design variables. Secondly, to establish a comprehensive optimization objective function considering both the operational performance and the hydraulic performance of the pump, the information weight method was adopted by weighting four evaluation indexes, namely, head coefficient, efficiency coefficient, vortex average radial deflection coefficient and axial velocity uniformity coefficient, which were calculated by numerical simulation. Finally, the relevant optimization design analysis was carried out by establishing the response surface model, with the optimal objective value obtained by conducting the steepest-descent method. The results show that the response of the radial inlet and outlet clearance width coefficient between stator and rotor to the comprehensive objective function is not directly coupled and the influence of the radial inlet clearance width coefficient on the objective function is higher than that of the radial outlet clearance width coefficient. The parameter optimization outcomes are as follows: the width coefficient of radial inlet clearance between stator and rotor is 2.2 and that of radial outlet clearance is 3.6, in which case the disturbance effect of clearance flow on the mainstream flow pattern in the pump can be significantly reduced, with the export cyclic quantity of the guide vane obviously decreased and the outlet flow pattern of the pump unit greatly improved. Verified by the model test, the average lift of the pump unit was increased by about 7.6% and the maximum promotion of the unit efficiency reached 5.2%.

26 December 2025 in Water
Verified
Journal Article
Open access
PDF file
HWHongliang Wang
Hongliang Wang
ALAng Li
Ang Li
CWChuan Wang
Chuan Wang
SLShuai Liu
Shuai Liu
YSYansheng Shi
Yansheng Shi
XJXuanwen Jia
Xuanwen Jia
Semi-open impeller sewage pumps are widely used in fields such as municipal wastewater treatment. However, they often face performance degradation and operational instability when conveying solid–liquid two-phase flows containing solid particles. This study aims to systematically elucidate the influence mechanisms of particle diameter (0.5–3.0 mm) and volume fraction (1–20%) on the external characteristics and internal flow field of semi-open impeller sewage pumps, providing a theoretical basis for optimizing their design and operational stability. Using an 80WQ4QG-type sewage pump as the research subject, this study employed a combination of numerical simulation and experimental research. The standard k-ε turbulence model coupled with the Discrete Phase (Particle) approach was adopted for multi-condition solid–liquid two-phase flow simulations. Furthermore, two-way analysis of variance (two-way ANOVA) was utilized to quantify the main effects and interaction effects of the parameters. The results indicate that the pump head and efficiency generally exhibit a decreasing trend with increasing particle diameter or volume fraction, with particle diameter exerting a more pronounced effect (p < 0.01). When the particle diameter increased to 3.0 mm, the head decreased by 5.66%; when the volume fraction rose to 20%, the head decreased by 4.17%. It is noteworthy that the combination of a 0.5 mm particle diameter and a 20% volume fraction resulted in an abnormal increase in head, suggesting a possible flow pattern optimization under specific conditions. Analysis of the internal flow field reveals that coarse particles (≥1.5 mm) intensify the pressure gradient disparity between the front and rear shroud cavities of the impeller, thereby increasing the axial thrust. A high volume fraction (≥10%) promotes pronounced flow separation in the volute tongue region and exacerbates the risk of localized erosion at the outlet.