Baosheng Wang

Dr. Baosheng Wang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JLJianian Li
Jianian Li
BWBaosheng Wang
Baosheng Wang
DZDajun Zhang
Dajun Zhang
CLChenzhe Li
Chenzhe Li
YZYihui Zhu
Yihui Zhu
Xiong WangXiong Wang
Xiong Wang
Objective: As a newly developed technique, focused microwave breast hyperthermia (FMBH) can provide accurate and cost-effective treatment of breast tumors with low side effect. A clinically feasible FMBH system requires a guidance technique to monitor the microwave power distribution in the breast. Compressive thermoacoustic tomography (CTT) is a suitable guidance approach for FMBH, which is more cost-effective than MRI. However, no experimental validation based on a realized FMBH-CTT system has been reported, which greatly hinders the further advancement of this novel approach. Methods: We developed a preclinical system prototype for the FMBH-CTT technique, containing a microwave phased antenna array, a microwave source, an ultrasound transducer array and associated data acquisition module. Results: Experimental results employing homogeneous and inhomogeneous breast-mimicking phantoms demonstrate that the CTT technique can offer reliable guidance for the entire process of the FMBH. In addition, small phase noises do not deteriorate the overall performance of the system prototype. Conclusion: The realized preclinical FMBH-CTT system prototype is capable for noninvasive, accurate and low-side-effect breast tumor treatment with effective guidance. Significance: The experimentally validated FMBH-CTT system prototype provides a feasible paradigm for CTT guided FMBH, establishes a practical platform for future improvement of this technique, and paves the way for potential clinical translation.

10 September 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
BWBaosheng Wang
Baosheng Wang
YSYifei Sun
Yifei Sun
ZWZhicheng Wang
Zhicheng Wang
Xiong WangXiong Wang
Xiong Wang
Microwave-induced thermoacoustic imaging (MITAI) has found diversified applications in biomedical related disciplines and holds the potential to serve as an auxiliary measure for diagnosis and treatment in clinics. Conventional imaging algorithms for MITAI, for example, back-projection (BP), require exceedingly intensive sampling of thermoacoustic signals stemming from a sample under test, and thus, suffer from deficiencies such as low time efficiency, high system cost, and more microwave radiation received by patients. Combining compressive sensing (CS) and MITAI, referred to as CS-MITAI, is promising to address the problem. Reported experiments in two dimensions and simulations in three dimensions (3D) have proved that the CS-MITAI approach can reliably reconstruct images with much fewer measurements than the BP algorithm. However, there is a pressing need for the experimental validation of the CS-MITAI technique in a real three-dimensional (3-D) environment, which has profound implications for its practical applications and further improvement. This article experimentally investigates the 3-D CS-MITAI technique by imaging a sample with 3-D features. Establishment of a dictionary is crucial for the successful implementation of the 3-D CS-MITAI approach. An analytical method is proposed to build the dictionary with much higher efficiency than other reported measures, and its detailed derivation is provided. In addition, modeling work and parametric studies are performed to explore the robustness of the 3-D CS-MITAI mechanism in dealing with different cases. Both simulation and experimental results show that the 3-D CS-MITAI modality can offer comparable imaging quality as the BP method but requires 200 and 68 times fewer measurements, respectively.

10 February 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
CLChenzhe Li
Chenzhe Li
ZXZijun Xi
Zijun Xi
GJGaofei Jin
Gaofei Jin
WJWeichao Jiang
Weichao Jiang
BWBaosheng Wang
Baosheng Wang
Xiong WangXiong Wang
Xiong Wang
Objective: Hemorrhagic stroke is a leading threat to human's health. The fast-developing microwave-induced thermoacoustic tomography (MITAT) technique holds potential to do brain imaging. However, transcranial brain imaging based on MITAT is still challenging due to the involved huge heterogeneity in speed of sound and acoustic attenuation of human skull. This work aims to address the adverse effect of the acoustic heterogeneity using a deep-learning-based MITAT (DL-MITAT) approach for transcranial brain hemorrhage detection. Methods: We establish a new network structure, a residual attention U-Net (ResAttU-Net), for the proposed DL-MITAT technique, which exhibits improved performance as compared to some traditionally used networks. We use simulation method to build training sets and take images obtained by traditional imaging algorithms as the input of the network. Results: We present ex-vivo transcranial brain hemorrhage detection as a proof-of-concept validation. By using an 8.1-mm thick bovine skull and porcine brain tissues to perform ex-vivo experiments, we demonstrate that the trained ResAttU-Net is capable of efficiently eliminating image artifacts and accurately restoring the hemorrhage spot. It is proved that the DL-MITAT method can reliably suppress false positive rate and detect a hemorrhage spot as small as 3 mm. We also study effects of several factors of the DL-MITAT technique to further reveal its robustness and limitations. Conclusion: The proposed ResAttU-Net-based DL-MITAT method is promising for mitigating the acoustic inhomogeneity issue and performing transcranial brain hemorrhage detection. Significance: This work provides a novel ResAttU-Net-based DL-MITAT paradigm and paves a compelling route for transcranial brain hemorrhage detection as well as other transcranial brain imaging applications.

2 March 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Open access
ZLZhaoxu Luo
Zhaoxu Luo
CLChenzhe Li
Chenzhe Li
DLDantong Liu
Dantong Liu
BWBaosheng Wang
Baosheng Wang
LZLejia Zhang
Lejia Zhang
Xiong WangXiong Wang
Xiong Wang
Quantitative reconstruction of dielectric properties has enabled a wealth of biomedical applications. Although traditional microwave imaging and microwave-induced thermoacoustic tomography (MITAT) techniques have been widely explored for quantitative reconstruction, it is still highly challenging for them to deal with biological samples with high permittivity and conductivity. This work leverages deep-learning-enabled MITAT (DL-MITAT) approach to quantitatively reconstruct dielectric properties of biological samples with high quality. We construct a new network structure to separately reconstruct the permittivity and conductivity. By simulation and experimental testing, we demonstrate that the DL-MITAT technique is able to reliably reconstruct inhomogeneous biological samples with tumor, muscle, and fat. The experimental reconstruction error is only 5%. The network exhibits excellent generalization capability in terms of sample’s geometry. This work provides a useful paradigm and alternative way for quantitative reconstruction of dielectric properties and paves the way toward practical applications.

31 August 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YSYifei Sun
Yifei Sun
CLChenzhe Li
Chenzhe Li
BWBaosheng Wang
Baosheng Wang
Xiong WangXiong Wang
Xiong Wang
Microwave-induced thermoacoustic tomography (MITAT) is suitable for detecting foreign bodies (FBs) in human body due to the sufficient microwave contrast between the FBs and surrounding human tissues. But detection of both hot and cold FBs by the same modality has not been demonstrated. In addition, traditional widely used imaging algorithms for MITAT requires highly intensive measurements, which is not cost-effective or time-efficient. This work reports the application of a low-cost compressive thermoacoustic tomography (CTAT) system for the detection of both hot and cold FBs embedded in tissues, referred to as FBD. We give detailed description of the theory of MITAT and CTAT. We show experimental demonstrations using different shaped metallic samples as the hot FBs and glass and wood samples as the cold FBs. We achieve successful detection of all the hot and cold FBs embedded in different tissues. The CTAT-FBD method is a new paradigm promising for a bunch of diagnosis or sensing applications. It is also possible to build a portable system for this technique.

13 May 2021 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
BWBaosheng Wang
Baosheng Wang
NXNaping Xiong
Naping Xiong
YSYifei Sun
Yifei Sun
LZLejia Zhang
Lejia Zhang
CLChenzhe Li
Chenzhe Li
Xiong WangXiong Wang
Xiong Wang
Microwave-induced thermoacoustic tomography (MITAI) has found diversified applications in biomedical related disciplines. This work reports a novel MITAI modality to homogenize the microwave power deposition in the sample and improve the image quality for small animal imaging via scanning orthogonal polarization (SOP) excitation. Although circular polarization excitation has been reported to enhance MITAI, we perform some simulation works using realistic breast phantoms to prove that the homogeneity of microwave power distribution in the phantoms using orthogonal polarization excitation is comparable to that using circular polarization excitation. Compressive sensing is also applied to enhance the time efficiency of the system. Experiments applying a mouse and a frog sample are conducted. The results indicate that the SOP excitation mechanism can completely reveal the structure of the small animals due to improved power homogeneity. The proposed MITAI-SOP technique is superior to circularly polarized antenna (CPA) based modality since the former avoids the deficiency of CPA in bandwidth, power capacity and efficiency. This work presents a practical and easy-to-implement paradigm for high-quality imaging of small animals and big biological samples using MITAI.