Khalfan Al Kharusi

Mr. Khalfan Al Kharusi

Sultan Qaboos University, Muscat, Masqaţ, Oman
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
KKKhalfan Al Kharusi
Khalfan Al Kharusi
AEAbdelsalam M. Elhaffar
Abdelsalam M. Elhaffar
MMMostefa Mesbah
Mostefa Mesbah
Integrating inverter-based generators in power systems introduces several challenges to conventional protection relays. The fault characteristics of these generators depend on the inverters’ control strategy, which matters in the detection and classification of the fault. This paper presents a comprehensive machine-learning-based approach for detecting and classifying faults in transmission lines connected to inverter-based generators. A two-layer classification approach was considered: fault detection and fault type classification. The faults were comprised of different types at several line locations and variable fault impedance. The features from instantaneous three-phase current and voltages and calculated swing-center voltage (SCV) were extracted in time, frequency, and time–frequency domains. A photovoltaic (PV) and a Doubly-Fed Induction Generator (DFIG) wind farm plant were the considered renewable resources. The unbalanced data problem was investigated and mitigated using the synthetic minority class oversampling technique (SMOTE). The hyperparameters of the evaluated classifiers, namely decision trees (DT), Support Vector Machines (SVM), k-Nearest Neighbors (k-NN), and Ensemble trees, were optimized using the Bayesian optimization algorithm. The extracted features were reduced using several methods. The classification performance was evaluated in terms of the accuracy, specificity, sensitivity, and precision metrics. The results show that the data balancing improved the specificity of DT, SVM, and k-NN classifiers (DT: from 99.86% for unbalanced data to 100% for balanced data; SVM: from 99.28% for unbalanced data to 99.93% for balanced data; k-NN: from 99.64% for unbalanced data to 99.74% for balanced data). The forward feature selection combined with the Bag ensemble classifier achieved 100% accuracy, sensitivity, specificity, and precision for fault detection (binary classification), while the Adaboost ensemble classifier had the highest accuracy (99.4%), compared to the other classifiers when using the complete set of features. The classification models with the highest performance were further tested using a new dataset test case. They showed high detection and classification capabilities. The proposed approach was compared with the previous methodologies from the literature.

2 August 2023 in Energies
Verified
Journal Article
Open access
PDF file
KKKhalfan Al Kharusi
Khalfan Al Kharusi
AEAbdelsalam M. Elhaffar
Abdelsalam M. Elhaffar
MMMostefa Mesbah
Mostefa Mesbah
Adaptive protection schemes have been developed to address the problem of behavior-changing power systems integrated with inverter-based generation (IBG). This paper proposes a machine-learning-based fault detection and classification technique using a setting-group-based adaptation approach. Multigroup settings were designed depending on the types of power generation (synchronous generator, PV plant, and type-3 wind farm) connected to a transmission line in the 39-Bus New England System. For each system topology, an optimized pretrained ensemble tree classifier was used. The adaptation process has two phases: an offline learning phase to tune the classifiers and select the optimum subset of features, and an online phase where the circuit breaker (CB) status and the active output power of the generators are continuously monitored to identify the current system topology and to select the appropriate setting group. The proposed system achieved an average accuracy of 99.4%, a 99.5% average precision, a 99.9% average specificity, and a 99.4% average sensitivity of classification. The robustness analysis was conducted by applying several fault scenarios not considered during training, which include different transmission network configurations and different penetration levels of IBGs. The case of incorrect selection of the appropriate setting group resulting from selecting the wrong topology is also considered. It was noticed that the performance of developed classifiers deteriorates when the transmission network is reconfigured and the incorrect setting group is selected.