Bandar Alanazi

Dr. Bandar Alanazi


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MAMohammed Alsufayan
Mohammed Alsufayan
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
RMRayan Moslem
Rayan Moslem
AAAbdullah Asiri
Abdullah Asiri
AAAbdullah Alomary
Abdullah Alomary
DBDAVID BRADLEY
DAVID BRADLEY
In the screening and identifying of colon and rectum malignancy, computed tomography colonography (CTC) is a highly effective imaging technique, albeit patients receiving a significant effective dose. Accordingly, patient dose evaluation is an important need, seeking to ensure benefits outweigh the projected cancer risk. Objective: For CTC procedures carried out in the Radiology Department, Medical Imaging Operation Services, King Fahad Medical City (KFMC), evaluation is done using the current American College of Radiology (ACR) imaging protocol and concomitant patient-effective doses. Study is carried out on a sample size of 55 CTC procedures, involving 25 males (45%) and 30 females (55%). The patients were classified as follows: two groups based on CT machine; four groups based on the applied protocol; and three groups based on the procedure results. All procedures were carried out using two machines, the products of two different vendors (a GE Healthcare DISCOVERY CT 750 HD 64 slices dual-energy scanner and a Philips Brilliance CT 64 slices scanner). The overall mean, standard deviation (SD), median, and range of the effective dose (in mSv) were 11.57 ± 7.75, 9.25 (2.17–31.93). Automatic tube current modulation (ATCM) shows a significant increase in CTDIvol up to 69% and effective dose (mSv) up to 95% than the manual tube current (mA) compared to the standard protocol. The CT protocol variation results in a three-fold variation in patient-effective dose. The technologist role is crucial in selecting a noise reference based on patient weight and adjusting tube current per slice to avoid overexposure during ATCM protocol.

30 January 2023 in Tomography
Verified
Journal Article
Open access
PDF file
EAEssam Mohammed Alkhaybari
Essam Mohammed Alkhaybari
SASalman Albeshan
Salman Albeshan
BABandar Alanazi
Bandar Alanazi
RARaghad Mustafa Alfarraj
Raghad Mustafa Alfarraj
RARakan Walid Alduhaim
Rakan Walid Alduhaim
RTRima Tulbah
Rima Tulbah
Objective: This study aims to establish a local diagnostic reference level (LDRL) for single-photon emission tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) with respect to myocardial perfusion imaging (MPI). Materials and Methods: The acquisition protocol and dosimetry data on the MPI procedures of five SPECT/CT scans and one PET/CT scan were collected. Data on technitum-99m sestamibi (99mTc-sestamibi), 99mTc-tetrofosmin, thallium-201 (201Tl), and rubidium-82 (82RB) were all collected from one centre via questionnaire booklets. Descriptive data analysis was used to analyse all variables, and the 50th percentile was used to analyse each radiation dose quantity. Results: The reported 50th percentile dose for a one-day stress/rest protocol using 99mTc-sestamibi (445/1147 MBq) and 99mTc-tetrofosmin (445/1147 MBq) and for a two-day stress/rest protocol using 99mTc-sestamibi (1165/1184 MBq) and 99mTc-tetrofosmin (1221/1184 MBq) are in good agreement with reported national diagnostic reference levels (NDRLs). However, the dose from the study data on a one-day stress/rest protocol using 99mTc-sestamibi was more than the 50th percentile dose from the Brazilian data (370/1110 MBq) on a similar protocol, and the dose from the study data on a two-day stress/rest protocol using 99mTc-tetrofosmin was more than the 50th percentile dose (1084/1110 MBq) from the United States data on MPI scans. Regarding the computed tomography (CT) portion of the SPECT/CT framework, the 50th percentile doses were lower than all the identified doses in the data considered in the literature reviewed. However, regarding the CT component of the PET/CT MPI scans, the 82RB dose was more than the recorded doses in the CT data in the published literature. Conclusion: This study determined the LDRL of five SPECT/CT protocols and one PET/CT MPI protocol. The results suggest that there may be opportunities to optimise the patient radiation burden from administered activities in patients undergoing SPECT examinations and the CT components associated with 82RB PET/CT scans without compromising diagnostic image quality.