Essam Mohammed Alkhaybari

Dr. Essam Mohammed Alkhaybari


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in Tomography
Verified
Journal Article
Open access
PDF file
AAAli B Alhailiy
Ali B Alhailiy
EAEssam Mohammed Alkhaybari
Essam Mohammed Alkhaybari
SASultan Alghamdi
Sultan Alghamdi
NFNada Fisal
Nada Fisal
SASultan Aldosari
Sultan Aldosari
SASalman Albeshan
Salman Albeshan
Brain computed tomography (CT) is a diagnostic imaging tool routinely used to assess all paediatric neurologic disorders and other head injuries. Despite the continuous development of paediatric CT imaging, radiation exposure remains a concern. Using diagnostic reference levels (DRLs) helps to manage the radiation dose delivered to patients, allowing one to identify an unusually high dose. In this paper, we propose DRLs for paediatric brain CT examinations in Saudi clinical practices and compare the findings with those of other reported DRL studies. Data including patient and scanning protocols were collected retrospectively from three medical cities for a total of 225 paediatric patients. DRLs were derived for four different age groupings. The resulting DRL values for the dose–length product (DLP) for the age groups of newborns (0–1 year), 1-y-old (1–5 years), 5-y-old (5–10 years) and 10-y-old (10–15 years) were 404 mGy cm, 560 mGy cm, 548 mGy cm, and 742 mGy cm, respectively. The DRLs for paediatric brain CT imaging are comparable to or slightly lower than other DRLs due to the current use of dose optimisation strategies. This study emphasises the need for an international standardisation for the use of weight group categories in DRL establishment for paediatric care in order to provide a more comparable measurement of dose quantities across different hospitals globally.

15 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
AAAli B Alhailiy
Ali B Alhailiy
EAEssam Mohammed Alkhaybari
Essam Mohammed Alkhaybari
MAMohammed S Alshuhri
Mohammed S Alshuhri
AAAbdullah Yousef Al-Othman
Abdullah Yousef Al-Othman
THTarek Hegazi
Tarek Hegazi
MMMustafa Z. Mahmoud
Mustafa Z. Mahmoud
Objectives: Diagnostic reference levels (DRLs) are crucial tools for optimizing radiation exposure during different radiological examinations. This study aimed to establish preliminary DRLs for commonly performed computed tomographic angiography (CTA) examinations in Saudi Arabia. Methods: Data for three types of CTA examinations (cerebral, pulmonary, and lower-extremity) were collected from six medical cities across Saudi Arabia. Data sets related to 723 CTAs with a mean patient weight of 75 kg were analysed in detail. The DRL values were determined based on the 75th, median, and 25th CT dose index volume (CTDIvol) and dose length product (DLP) values. Results: The established DRLs were 1221 mGy cm for cerebral CTAs, 475 mGy cm for pulmonary CTAs, and 1040 mGy cm for lower-extremity CTAs. These values were comparable to those reported in other studies. Conclusions: This study provides preliminary DRLs for three common CTA procedures in Saudi Arabia. The widespread implementation of a low kVp and a high level of image reconstruction (IR) presents an opportunity for further dose reduction. These findings can serve as a foundation for future nationwide DRL surveys and the optimization of CTA imaging protocols in Saudi Arabia.

30 January 2023 in Tomography
Verified
Journal Article
Open access
PDF file
EAEssam Mohammed Alkhaybari
Essam Mohammed Alkhaybari
SASalman Albeshan
Salman Albeshan
BABandar Alanazi
Bandar Alanazi
RARaghad Mustafa Alfarraj
Raghad Mustafa Alfarraj
RARakan Walid Alduhaim
Rakan Walid Alduhaim
RTRima Tulbah
Rima Tulbah
Objective: This study aims to establish a local diagnostic reference level (LDRL) for single-photon emission tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) with respect to myocardial perfusion imaging (MPI). Materials and Methods: The acquisition protocol and dosimetry data on the MPI procedures of five SPECT/CT scans and one PET/CT scan were collected. Data on technitum-99m sestamibi (99mTc-sestamibi), 99mTc-tetrofosmin, thallium-201 (201Tl), and rubidium-82 (82RB) were all collected from one centre via questionnaire booklets. Descriptive data analysis was used to analyse all variables, and the 50th percentile was used to analyse each radiation dose quantity. Results: The reported 50th percentile dose for a one-day stress/rest protocol using 99mTc-sestamibi (445/1147 MBq) and 99mTc-tetrofosmin (445/1147 MBq) and for a two-day stress/rest protocol using 99mTc-sestamibi (1165/1184 MBq) and 99mTc-tetrofosmin (1221/1184 MBq) are in good agreement with reported national diagnostic reference levels (NDRLs). However, the dose from the study data on a one-day stress/rest protocol using 99mTc-sestamibi was more than the 50th percentile dose from the Brazilian data (370/1110 MBq) on a similar protocol, and the dose from the study data on a two-day stress/rest protocol using 99mTc-tetrofosmin was more than the 50th percentile dose (1084/1110 MBq) from the United States data on MPI scans. Regarding the computed tomography (CT) portion of the SPECT/CT framework, the 50th percentile doses were lower than all the identified doses in the data considered in the literature reviewed. However, regarding the CT component of the PET/CT MPI scans, the 82RB dose was more than the recorded doses in the CT data in the published literature. Conclusion: This study determined the LDRL of five SPECT/CT protocols and one PET/CT MPI protocol. The results suggest that there may be opportunities to optimise the patient radiation burden from administered activities in patients undergoing SPECT examinations and the CT components associated with 82RB PET/CT scans without compromising diagnostic image quality.

8 May 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
AAAhmad Abdulrahman Alhulail
Ahmad Abdulrahman Alhulail
SASalman Albeshan
Salman Albeshan
MAMohammed S Alshuhri
Mohammed S Alshuhri
EAEssam Mohammed Alkhaybari
Essam Mohammed Alkhaybari
MAMansour Almanaa
Mansour Almanaa
SASultan Alghamdi
Sultan Alghamdi
Background/Objectives: Digital mammography is widely used for breast cancer screening; however, variations in system design and automatic exposure control (AEC) strategies can lead to significant differences in radiation dose, potentially affecting the diagnostic quality and patient safety. In this study, we aimed to determine the effect of various mammographic technologies on the in vivo mean glandular doses (MGDs) that are received in clinical settings. Methods: The MGDs and applied acquisition parameters from 194,608 mammograms, acquired employing AEC using different digital mammography systems (GE, Siemens, and two different models of Hologic), were retrospectively collected. The potential variation in MGD resulting from different technologies (system and target/filter combination) was assessed employing the Kruskal–Wallis test, followed by Dunn’s post hoc. The AEC optimization of acquisition parameters (kVp, mAs) within each system was investigated through a multi-regression analysis as a function of the compressed breast thickness (CBT). The trend line of these parameters in addition to the MGD and source-to-breast distance were also plotted and compared. Results: There were significant variations in delivered doses per CBT based on which technology was used (p < 0.001). The regression analyses revealed system-specific differences in AEC adjustments of mAs and kVp in response to CBT changes. As the CBT increases, the MGD increases with different degrees, rates, and patterns across systems due to differences in AEC strategies. Conclusions: The MGD is affected by the applied technology, which is different between systems. Clinicians need to be aware of these variations and how they affect the MGD. Additionally, manufacturers may need to consider standardizing the implemented technology effects on the MGDs.

28 September 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
BABabar Ali
Babar Ali
MAMansour Alqahtani
Mansour Alqahtani
EAEssam Mohammed Alkhaybari
Essam Mohammed Alkhaybari
AAAli H D Alshehri
Ali H D Alshehri
MSMohammad Sayed
Mohammad Sayed
TATamoor Ali
Tamoor Ali
Background/Objective: Multimodal image registration plays a critical role in modern medical imaging, enabling the integration of complementary modalities such as positron emission tomography (PET) and computed tomography (CT). This study compares the performance of three widely used image registration techniques—Demons Image Registration with Modality Transformation, Free-Form Deformation using the Medical Image Registration Toolbox (MIRT), and MATLAB Intensity-Based Registration—in terms of improving PET/CT image alignment. Methods: A total of 100 matched PET/CT image slices from a clinical scanner were analysed. Preprocessing techniques, including histogram equalisation and contrast enhancement (via imadjust and adapthisteq), were applied to minimise intensity discrepancies. Each registration method was evaluated under varying parameter conditions with regard to sigma fluid (range 4–8), histogram bins (100 to 256), and interpolation methods (linear and cubic). Performance was assessed using quantitative metrics: root mean square error (RMSE), mean squared error (MSE), mean absolute error (MAE), the Pearson correlation coefficient (PCC), and standard deviation (STD). Results: Demons registration achieved optimal performance at a sigma fluid value of 6, with an RMSE of 0.1529, and demonstrated superior computational efficiency. The MIRT showed better adaptability to complex anatomical deformations, with an RMSE of 0.1725. MATLAB Intensity-Based Registration, when combined with contrast enhancement, yielded the highest accuracy (RMSE = 0.1317 at alpha = 6). Preprocessing improved registration accuracy, reducing the RMSE by up to 16%. Conclusions: Each registration technique has distinct advantages: the Demons algorithm is ideal for time-sensitive tasks, the MIRT is suited to precision-driven applications, and MATLAB-based methods offer flexible processing for large datasets. This study provides a foundational framework for optimising PET/CT image registration in both research and clinical environments.

29 April 2026 in Neurology International
Verified
Journal Article
Open access
PDF file
MAManal Aljuhani
Manal Aljuhani
AAAzhaar Ashraf
Azhaar Ashraf
AAAbdullah Alqarni
Abdullah Alqarni
MAMohammed S Alshuhri
Mohammed S Alshuhri
EAEssam Mohammed Alkhaybari
Essam Mohammed Alkhaybari
AAAhmad Abdulrahman Alhulail
Ahmad Abdulrahman Alhulail
Background: Vascular dysfunction and neurovascular inflammation are increasingly recognized as contributors to Alzheimer’s disease (AD) pathophysiology, particularly through interactions with tau-related neurodegeneration. Endothelial adhesion molecules, including vascular cell adhesion molecule-1 (VCAM-1) and intercellular adhesion molecule-1 (ICAM-1), play key roles in blood–brain barrier regulation and immune-vascular crosstalk, yet their relevance to long-term disease progression and established AD biomarkers remains incompletely understood. Methods: Using data from the Alzheimer’s Disease Neuroimaging Initiative (ADNI), we examined associations between baseline cerebrospinal fluid (CSF) levels of VCAM-1 and ICAM-1 and clinical progression, CSF biomarkers, neuroimaging measures, and cognitive outcomes over up to 10 years of follow-up. This study included 294 participants (87 cognitively normal, 129 with mild cognitive impairment, and 78 with AD). Multivariable logistic regression was used to assess associations with diagnostic progression, and linear regression models examined relationships with baseline and longitudinal measures of tau, amyloid-β, hippocampal volume, Fluorodeoxyglucose-Positron Emission Tomography (FDG-PET) metabolism, and cognition. Models were adjusted for age, sex, apolipoprotein E epsilon 4 (APOE ε4) status, baseline diagnosis, and baseline CSF amyloid-β, with false discovery rate correction applied for multiple comparisons. Results: Baseline CSF VCAM-1 and ICAM-1 levels did not differ across diagnostic groups. However, higher baseline levels of both markers were nominally associated with increased odds of disease progression. Notably, ICAM-1 showed a strong and robust association with baseline CSF phosphorylated tau, which remained significant after multiple-comparison correction. VCAM-1 was also associated with tau pathology, though this did not survive correction. Neither marker was associated with baseline or longitudinal changes in hippocampal volume, FDG-PET metabolism, or cognitive performance. Conclusion: CSF VCAM-1 and ICAM-1 appear to reflect neurovascular inflammatory processes linked to tau pathology rather than markers of clinical stage or longitudinal neurodegeneration. These findings support a role for endothelial activation in AD pathophysiology and highlight vascular–immune mechanisms as potential contributors to tau-related disease vulnerability.