Xie Xu

Xie Xu


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
JZJieping Zhou
Jieping Zhou
ZPZhao Peng
Zhao Peng
YSYuchen Song
Yuchen Song
YCYankui Chang
Yankui Chang
XPXi Pei
Xi Pei
XXXie Xu
Xie Xu
Purpose: To develop and test a three‐dimensional (3D) deep learning model for predicting 3D voxel‐wise dose distributions for intensity‐modulated radiotherapy (IMRT).Methods: A total of 122 postoperative rectal cancer cases treated by IMRT were considered in the study, of which 100 cases were randomly selected as the training–validating set and the remaining as the testing set. A 3D deep learning model named 3D U‐Res‐Net_B was constructed to predict 3D dose distributions. Eight types of 3D matrices from CT images, contoured structures, and beam configurations were fed into the independent input channel, respectively, and the 3D matrix of dose distributions was taken as the output to train the 3D model. The obtained 3D model was used to predict new 3D dose distributions. The predicted accuracy was evaluated in two aspects: (a) The dice similarity coefficients (DSCs) of different isodose volumes, the average dose difference of all voxels within the body, and 3%/5 mm global gamma passing rates of organs at risks (OARs) and planned target volume (PTV) were used to address the spatial correspondence between predicted and clinical delivered 3D dose distributions; (b) The dosimetric index (DI) including homogeneity index, conformity index, V50, V45 for PTV and OARs between predicted and clinical truth were statistically analyzed with the paired‐samples t test. The model was also compared with 3D U‐Net and the same architecture model without beam configurations input (named as 3D U‐Res‐Net_O).Results: The 3D U‐Res‐Net_B model predicted 3D dose distributions accurately. For the 22 testing cases, the average prediction bias ranged from −1.94% to 1.58%, and the overall mean absolute errors (MAEs) was 3.92 ± 4.16%; there was no statistically significant difference for nearly all DIs. The model had a DSCs value above 0.9 for most isodose volumes, and global 3D gamma passing rates varying from 0.81 to 0.90 for PTV and OARs, clearly outperforming 3D U‐Res‐Net_O and being slightly superior to 3D U‐Net.Conclusions: This study developed a more general deep learning model by considering beam configurations input and achieved an accurate 3D voxel‐wise dose prediction for rectal cancer treated by IMRT, a potentially easier clinical implementation for more comprehensive automatic planning.

25 November 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ZWZhi Wang
Zhi Wang
YCYankui Chang
Yankui Chang
ZPZhao Peng
Zhao Peng
YLYin Lv
Yin Lv
WSWeijiong Shi
Weijiong Shi
XXXie Xu
Xie Xu
Objective: To evaluate the accuracy of a deep learning‐based auto‐segmentation mode to that of manual contouring by one medical resident, where both entities tried to mimic the delineation "habits" of the same clinical senior physician.Methods: This study included 125 cervical cancer patients whose clinical target volumes (CTVs) and organs at risk (OARs) were delineated by the same senior physician. Of these 125 cases, 100 were used for model training and the remaining 25 for model testing. In addition, the medical resident instructed by the senior physician for approximately 8 months delineated the CTVs and OARs for the testing cases. The dice similarity coefficient (DSC) and the Hausdorff Distance (HD) were used to evaluate the delineation accuracy for CTV, bladder, rectum, small intestine, femoral‐head‐left, and femoral‐head‐right.Results: The DSC values of the auto‐segmentation model and manual contouring by the resident were, respectively, 0.86 and 0.83 for the CTV (P < 0.05), 0.91 and 0.91 for the bladder (P > 0.05), 0.88 and 0.84 for the femoral‐head‐right (P < 0.05), 0.88 and 0.84 for the femoral‐head‐left (P < 0.05), 0.86 and 0.81 for the small intestine (P < 0.05), and 0.81 and 0.84 for the rectum (P > 0.05). The HD (mm) values were, respectively, 14.84 and 18.37 for the CTV (P < 0.05), 7.82 and 7.63 for the bladder (P > 0.05), 6.18 and 6.75 for the femoral‐head‐right (P > 0.05), 6.17 and 6.31 for the femoral‐head‐left (P > 0.05), 22.21 and 26.70 for the small intestine (P > 0.05), and 7.04 and 6.13 for the rectum (P > 0.05). The auto‐segmentation model took approximately 2 min to delineate the CTV and OARs while the resident took approximately 90 min to complete the same task.Conclusion: The auto‐segmentation model was as accurate as the medical resident but with much better efficiency in this study. Furthermore, the auto‐segmentation approach offers additional perceivable advantages of being consistent and ever improving when compared with manual approaches.

30 May 2018 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
LZLian Zhang
Lian Zhang
ZWZhi Wang
Zhi Wang
CSChengyu Shi
Chengyu Shi
TLTengfei Long
Tengfei Long
XXXie Xu
Xie Xu
Deformable image registration (DIR) is the key process for contour propagation and dose accumulation in adaptive radiation therapy (ART). However, currently, ART suffers from a lack of understanding of “robustness” of the process involving the image contour based on DIR and subsequent dose variations caused by algorithm itself and the presetting parameters. The purpose of this research is to evaluate the DIR caused variations for contour propagation and dose accumulation during ART using the RayStation treatment planning system. Ten head and neck cancer patients were selected for retrospective studies. Contours were performed by a single radiation oncologist and new treatment plans were generated on the weekly CT scans for all patients. For each DIR process, four deformation vector fields (DVFs) were generated to propagate contours and accumulate weekly dose by the following algorithms: (a) ANACONDA with simple presetting parameters, (b) ANACONDA with detailed presetting parameters, (c) MORFEUS with simple presetting parameters, and (d) MORFEUS with detailed presetting parameters. The geometric evaluation considered DICE coefficient and Hausdorff distance. The dosimetric evaluation included D95, Dmax, Dmean, Dmin, and Homogeneity Index. For geometric evaluation, the DICE coefficient variations of the GTV were found to be 0.78 ± 0.11, 0.96 ± 0.02, 0.64 ± 0.15, and 0.91 ± 0.03 for simple ANACONDA, detailed ANACONDA, simple MORFEUS, and detailed MORFEUS, respectively. For dosimetric evaluation, the corresponding Homogeneity Index variations were found to be 0.137 ± 0.115, 0.006 ± 0.032, 0.197 ± 0.096, and 0.006 ± 0.033, respectively. The coherent geometric and dosimetric variations also consisted in large organs and small organs. Overall, the results demonstrated that the contour propagation and dose accumulation in clinical ART were influenced by the DIR algorithm, and to a greater extent by the presetting parameters. A quality assurance procedure should be established for the proper use of a commercial DIR for adaptive radiation therapy.

30 September 2022 in Journal of Radiation Protection and Research
Verified
Journal Article
Open access
PDF file
ZPZhao Peng
Zhao Peng
NGNing Gao
Ning Gao
BWBingzhi Wu
Bingzhi Wu
ZCZhi Chen
Zhi Chen
XXXie Xu
Xie Xu
The exciting advancement related to the “modeling of digital human” in terms of a computational phantom for radiation dose calculations has to do with the latest hype related to deep learning. The advent of deep learning or artificial intelligence (AI) technology involving convolutional neural networks has brought an unprecedented level of innovation to the field of organ segmentation. In addition, graphics processing units (GPUs) are utilized as boosters for both real-time Monte Carlo simulations and AI-based image segmentation applications. These advancements provide the feasibility of creating three-dimensional (3D) geometric details of the human anatomy from tomographic imaging and performing Monte Carlo radiation transport simulations using increasingly fast and inexpensive computers. This review first introduces the history of three types of computational human phantoms: stylized medical internal radiation dosimetry (MIRD) phantoms, voxelized tomographic phantoms, and boundary representation (BREP) deformable phantoms. Then, the development of a person-specific phantom is demonstrated by introducing AI-based organ autosegmentation technology. Next, a new development in GPU-based Monte Carlo radiation dose calculations is introduced. Examples of applying computational phantoms and a new Monte Carlo code named ARCHER (Accelerated Radiation- transport Computations in Heterogeneous EnviRonments) to problems in radiation protection, imaging, and radiotherapy are presented from research projects performed by students at the Rensselaer Polytechnic Institute (RPI) and University of Science and Technology of China (USTC). Finally, this review discusses challenges and future research opportunities. We found that, owing to the latest computer hardware and AI technology, computational human body models are moving closer to real human anatomy structures for accurate radiation dose calculations.

1 November 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ZPZhao Peng
Zhao Peng
MNMing Ni
Ming Ni
HSHongming Shan
Hongming Shan
YLYu Lu
Yu Lu
YLYongzhe Li
Yongzhe Li
XXXie Xu
Xie Xu

30 May 2016 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
BLBaohui Liang
Baohui Liang
YGYiming Gao
Yiming Gao
ZCZhi Chen
Zhi Chen
XXXie Xu
Xie Xu
This paper evaluates effective dose (ED) of overweight and obese patients who undergo body computed tomography (CT) examinations. ED calculations were based on tissue weight factors in the International Commission on Radiological Protection Publication 103 (ICRP 103). ED per unit dose length product (DLP) are reported as a function of the tube voltage, body mass index (BMI) of patient. The VirtualDose software was used to calculate ED for male and female obese phantoms representing normal weight, overweight, obese 1, obese 2 and obese 3 patients. Five anatomic regions (chest, abdomen, pelvis, abdomen/pelvis and chest/abdomen/pelvis) were investigated for each phantom. The conversion factors were computed from the DLP, and then compared with data previously reported by other groups. It was observed that tube voltage and BMI are the major factors that influence conversion factors of obese patients, and that ED computed using ICRP 103 tissue weight factors were 24% higher for a CT chest examination and 21% lower for a CT pelvis examination than the ED using ICRP 60 factors. For body CT scans, increasing the tube voltage from 80 to 140 kVp would increase the conversion factors by as much as 19–54% depending on the patient's BMI. Conversion factor of female patients was ~7% higher than the factors of male patients. DLP and conversion factors were used to estimate ED, where conversion factors depended on tube voltage, sex, BMI and tissue weight factors. With increasing number of obese individuals, using size-dependence conversion factors will improve accuracy, in estimating patient radiation dose.