Zhao Peng

Zhao Peng

Auto-generated profile, based on publicly available information

Zhao Peng

University of Science and Technology of China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2020 in Medical Physics
Verified
Journal Article
Open access
PDF file
ZPZhao Peng
Zhao Peng
XFXi Fang
Xi Fang
PYPingkun Yan
Pingkun Yan
HSHongming Shan
Hongming Shan
TITianyu (Unable to Review Indefinitely) Liu (Unable to Review Indefinitely)
Tianyu (Unable to Review Indefinitely) Liu (Unable to Review Indefinitely)
XXX. George Xu
X. George Xu
Purpose: One technical barrier to patient‐specific computed tomography (CT) dosimetry has been the lack of computational tools for the automatic patient‐specific multi‐organ segmentation of CT images and rapid organ dose quantification. When previous CT images are available for the same body region of the patient, the ability to obtain patient‐specific organ doses for CT — in a similar manner as radiation therapy treatment planning — will open the door to personalized and prospective CT scan protocols. This study aims to demonstrate the feasibility of combining deep‐learning algorithms for automatic segmentation of multiple radiosensitive organs from CT images with the GPU‐based Monte Carlo rapid organ dose calculation.Methods: A deep convolutional neural network (CNN) based on the U‐Net for organ segmentation is developed and trained to automatically delineate multiple radiosensitive organs from CT images. Two databases are used: The lung CT segmentation challenge 2017 (LCTSC) dataset that contains 60 thoracic CT scan patients, each consisting of five segmented organs, and the Pancreas‐CT (PCT) dataset, which contains 43 abdominal CT scan patients each consisting of eight segmented organs. A fivefold cross‐validation method is performed on both sets of data. Dice similarity coefficients (DSCs) are used to evaluate the segmentation performance against the ground truth. A GPU‐based Monte Carlo dose code, ARCHER, is used to calculate patient‐specific CT organ doses. The proposed method is evaluated in terms of relative dose errors (RDEs). To demonstrate the potential improvement of the new method, organ dose results are compared against those obtained for population‐average patient phantoms used in an off‐line dose reporting software, VirtualDose, at Massachusetts General Hospital.Results: The median DSCs are found to be 0.97 (right lung), 0.96 (left lung), 0.92 (heart), 0.86 (spinal cord), 0.76 (esophagus) for the LCTSC dataset, along with 0.96 (spleen), 0.96 (liver), 0.95 (left kidney), 0.90 (stomach), 0.87 (gall bladder), 0.80 (pancreas), 0.75 (esophagus), and 0.61 (duodenum) for the PCT dataset. Comparing with organ dose results from population‐averaged phantoms, the new patient‐specific method achieved smaller absolute RDEs (mean ± standard deviation) for all organs: 1.8% ± 1.4% (vs 16.0% ± 11.8%) for the lung, 0.8% ± 0.7% (vs 34.0% ± 31.1%) for the heart, 1.6% ± 1.7% (vs 45.7% ± 29.3%) for the esophagus, 0.6% ± 1.2% (vs 15.8% ± 12.7%) for the spleen, 1.2% ± 1.0% (vs 18.1% ± 15.7%) for the pancreas, 0.9% ± 0.6% (vs 20.0% ± 15.2%) for the left kidney, 1.7% ± 3.1% (vs 19.1% ± 9.8%) for the gallbladder, 0.3% ± 0.3% (vs 24.2% ± 18.7%) for the liver, and 1.6% ± 1.7% (vs 19.3% ± 13.6%) for the stomach. The trained automatic segmentation tool takes <5 s per patient for all 103 patients in the dataset. The Monte Carlo radiation dose calculations performed in parallel to the segmentation process using the GPU‐accelerated ARCHER code take <4 s per patient to achieve <0.5% statistical uncertainty in all organ doses for all 103 patients in the database.Conclusion: This work shows the feasibility to perform combined automatic patient‐specific multi‐organ segmentation of CT images and rapid GPU‐based Monte Carlo dose quantification with clinically acceptable accuracy and efficiency.

5 June 2019 in IEEE Access
Verified
Journal Article
Open access
ZPZhao Peng
Zhao Peng
HSHongming Shan
Hongming Shan
TLTianyu Liu
Tianyu Liu
XPXi Pei
Xi Pei
Ge WangGe Wang
Ge Wang
XXX. George Xu
X. George Xu
X-ray computed tomography (CT) is a popular diagnostic imaging tool that has caused public concern over potential radiation risks to the patient. Monte Carlo (MC) simulations are the most accurate methods to calculate x-ray interactions with the patient's body and voxel-wise dose distributions, but the statistical methods suffer from extremely long computing time that is required to achieve necessary statistical precision. In this paper, we propose and demonstrate the Monte Carlo Denoising Net (MCDNet), a convolutional encoder-decoder neural network, for the purpose of accelerating the MC radiation transport simulations for patient CT dosimetry. A unique set of full-body anatomically realistic adult voxel phantoms of various sizes and a GPU-based parallel MC code were used to produce adequate training and testing data for supervised learning. Gamma index passing rate (GIPR) was used to evaluate the performance of predicted dose maps. For CT scan protocols considered in this study, MCDNet is found to have the ability of predicting dose maps of $9.9\times 10 ^{\mathbf {7}}$ photons from corresponding dose maps of $1.3\times 10^{\mathbf {6}}$ photons, yielding $76\times $ speed-up in terms of photon numbers used in the MC simulations. MCDNet is the first CNN-based method to speed-up MC radiation transport simulations involving 3D and heterogeneous patient anatomies for x-ray CT. Future studies will test the feasibility of applying the deep-learning based denoising strategy to other MC radiation transport applications.

1 November 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ZPZhao Peng
Zhao Peng
MNMing Ni
Ming Ni
HSHongming Shan
Hongming Shan
YLYu Lu
Yu Lu
YLYongzhe Li
Yongzhe Li
XXXie Xu
Xie Xu

17 March 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
ZPZhao Peng
Zhao Peng
YLYu Lu
Yu Lu
YXYao Xu
Yao Xu
YLYongzhe Li
Yongzhe Li
BCBo Cheng
Bo Cheng
XXXie Xu
Xie Xu
Objective. This paper describes the development and validation of a GPU-accelerated Monte Carlo (MC) dose computing module dedicated to organ dose calculations of individual patients undergoing nuclear medicine (NM) internal radiation exposures involving PET/CT examination. Approach . This new module extends the more-than-10-years-long ARCHER project that developed a GPU-accelerated MC dose engine by adding dedicated NM source-definition features. To validate the code, we compared dose distributions from the point ion source, including 18 F, 11 C, 15 O, and 68 Ga, calculated for a water phantom against a well-tested MC code, GATE. To demonstrate the clinical utility and advantage of ARCHER-NM, one set of 18 F-FDG PET/CT data for an adult male NM patient is calculated using the new code. Radiosensitive organs in the CT dataset are segmented using a CNN-based tool called DeepViewer. The PET image intensity maps are converted to radioactivity distributions to allow for MC radiation transport dose calculations at the voxel level. The dose rate maps and corresponding statistical uncertainties were calculated at the acquisition time of PET image. Main results. The water-phantom results show excellent agreement, suggesting that the radiation physics module in the new NM code is adequate. The dose rate results of the 18 F-FDG PET imaging patient show that ARCHER-NM’s results agree very well with those of the GATE within −2.45% to 2.58% (for a total of 28 organs considered in this study). Most impressively, ARCHER-NM obtains such results in 22 s while it takes GATE about 180 min for the same number of 5 × 10 8 simulated decay events. Significance. This is the first study presenting GPU-accelerated patient-specific MC internal radiation dose rate calculations for clinically realistic 18 F-FDG PET/CT imaging case involving autosegmentation of whole-body PET/CT images. This study suggests that the proposed computing tools—ARCHER-NM— are accurate and fast enough for routine internal dosimetry in NM clinics.

2 April 2021
Verified
Book Chapter
Closed access
PDF file
ZPZhao Peng
Zhao Peng
JZJieping Zhou
Jieping Zhou
XFXi Fang
Xi Fang
PYPingkun Yan
Pingkun Yan
HSHongming Shan
Hongming Shan
XPXi Pei
Xi Pei
<!----> <!----> Data augmentation is a popular technique for reducing overfitting and improving generalization capabilities of deep neural networks. Augmentation encompasses a suite of techniques that enhances the size and diversity of training datasets. It plays a critical role when the amount of high-quality ground truth data is limited, and acquiring new examples is costly and time consuming, a very common problem in medical image analysis, including auto-segmentation for radiation therapy. This chapter reviews current advances in data augmentation techniques applied to auto-segmentation in radiation oncology, including geometric transformations, intensity transformation, and artificial data generation. In addition, an example application of these data augmentation methods for training deep neural networks for segmentation in the domain of radiation therapy is provided. <!----> <!---->