Katrin Reder-Christ

Dr. Katrin Reder-Christ


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2011 in Sensors
Verified
Journal Article
Open access
PDF file
KRKatrin Reder-Christ
Katrin Reder-Christ
Gerd BendasGerd Bendas
Gerd Bendas
Antibacterials are among of the most important medications used in health care. However, their efficacy is increasingly impeded by a tremendous and globally spread bacterial resistance phenomenon. This bacterial resistance is accelerated by inadequate application of antibacterial drugs in humans, the widespread veterinary use of antibacterials, and antibacterial occurrence in the environment and food. Further, there is a lack of development of innovative novel drugs. Therefore, the search for novel antibacterials has to be intensified and the spread of antibacterials in the environment has to be restricted. Due to the fundamental progress in biosensor development and promising applications in the antibiotic field, this review gives for the first time an overview on the use and prospects of biosensor applications in that area. A number of reports have applied biosensors of different design and techniques to search for antibacterials in environmental and foodstuff matrices. These studies are discussed with respect to the analytical values and compared to conventional techniques. Furthermore, biosensor applications to elucidate the mode of action of antimicrobial drugs in vitro have been described. These studies were critically introduced referring to the informational value of those simulations. In summary, biosensors will be illustrated as an innovative and promising, although not yet comprehensively applied, technique in the antibacterial field.

1 March 2007 in Biochimica et Biophysica Acta (BBA) - Biomembranes
Verified
Journal Article
Closed access
KRKatrin Reder-Christ
Katrin Reder-Christ
IWImke Wiedemann
Imke Wiedemann
Udo BakowskyUdo Bakowsky
Udo Bakowsky
HSHans-Georg Sahl
Hans-Georg Sahl
GBGerd Bendas
Gerd Bendas

14 November 2008 in The Journal of Membrane Biology
Verified
Journal Article
Closed access
PDF file
KRKatrin Reder-Christ
Katrin Reder-Christ
SASaad Al-Kaddah
Saad Al-Kaddah
IWImke Wiedemann
Imke Wiedemann
BRBernd Rattay
Bernd Rattay
HSHans-Georg Sahl
Hans-Georg Sahl
GBGerd Bendas
Gerd Bendas

1 November 2005 in Photochemistry and Photobiology
Verified
Journal Article
Closed access
PDF file
KRKatrin Reder-Christ
Katrin Reder-Christ
HRHans‐Hermann Rüttinger
Hans‐Hermann Rüttinger
MHMatthias Höpfner
Matthias Höpfner
URUlrich Rothe
Ulrich Rothe
GBGerd Bendas
Gerd Bendas
Ketoprofen is an important anti‐inflammatory drug, but its dermal application is limited because of the photosensitizing properties causing phototoxic reactions of the skin when exposed to UV light. We have recently investigated the peroxide formation of ketoprofen in solutions of linoleic acid during UV irradiation. To continue these studies and focus on UV‐induced changes in membrane integrity and barrier function we established an in vitro model using two biosensor techniques simultaneously. Support‐fixed bilayers were irradiated with different doses of UV‐B up to damaging intensities with or without ketoprofen. Cyclic voltammetry was carried out to detect alterations in membrane permeability; quartz crystal microbalance (QCM) measurements were helpful in analyzing whether a permeability increase was caused by depletion of membrane components. In absence of ketoprofen, increasing UV‐B doses induce membrane permeabilities of both unsaturated and saturated bilayers. QCM measurements could not reveal a significant loss of membrane components as a reason for the permeability. In contrast, 0.3 mM ketoprofen induced a dose‐dependent increase in membrane permeability. QCM results indicated a mass loss. Although this model does not explain all molecular mechanisms of membrane damage by ketoprofen, the combined application of both QCM and CV is a novel and powerful tool to investigate functional mechanisms of UV‐induced membrane damages.

1 March 2011 in International Journal of Antimicrobial Agents
Verified
Journal Article
Closed access
KRKatrin Reder-Christ
Katrin Reder-Christ
HFHildegard Falkenstein-Paul
Hildegard Falkenstein-Paul
GKGabriela Klocek
Gabriela Klocek
SASaad Al-Kaddah
Saad Al-Kaddah
Udo BakowskyUdo Bakowsky
Udo Bakowsky
GBGerd Bendas
Gerd Bendas

13 September 2013 in Sensors
Verified
Journal Article
Open access
PDF file
KRKatrin Reder-Christ
Katrin Reder-Christ
PSPatrick Schmitz
Patrick Schmitz
MBMarian Bota
Marian Bota
UGUrsula Gerber
Ursula Gerber
HFHildegard Falkenstein-Paul
Hildegard Falkenstein-Paul
Gerd BendasGerd Bendas
Gerd Bendas
Model membrane approaches have attracted much attention in biomedical sciences to investigate and simulate biological processes. The application of model membrane systems for biosensor measurements is partly restricted by the fact that the integrity of membranes critically depends on the maintenance of an aqueous surrounding, while various biosensors require a preconditioning of dry sensors. This is for example true for the well-established surface acoustic wave (SAW) biosensor SAM®5 blue. Here, a simple drying procedure of sensor-supported model membranes is introduced using the protective disaccharide trehalose. Highly reproducible model membranes were prepared by the Langmuir-Blodgett technique, transferred to SAW sensors and supplemented with a trehalose solution. Membrane rehydration after dry incorporation into the SAW device becomes immediately evident by phase changes. Reconstituted model membranes maintain their full functionality, as indicated by biotin/avidin binding experiments. Atomic force microscopy confirmed the morphological invariability of dried and rehydrated membranes. Approximating to more physiological recognition phenomena, the site-directed immobilization of the integrin VLA-4 into the reconstituted model membrane and subsequent VCAM-1 ligand binding with nanomolar affinity were illustrated. This simple drying procedure is a novel way to combine the model membrane generation by Langmuir-Blodgett technique with SAW biosensor measurements, which extends the applicability of SAM®5 blue in biomedical sciences.