The main purpose of the presented research is to raise the efficiency of pumping stations’ operational work by developing a model for reducing energy costs in urban water supply systems. Pumping systems are responsible for a significant portion of the total electrical energy use. Significant opportunities exist to reduce the pumping energy through smart design, retrofitting, and operating practices. Today, considering the increase in pumping energy prices in water conveyance systems, the problem of optimal operation of pumping stations is very actual. The optimal operation of pumping stations was determined using a Genetic Algorithm Optimization (GAO) to achieve the minimum energy cost. The paper presents a novel management model for the optimal design and operation of water pumping systems on a real case study for the town of Gonabad in Iran. To achieve this goal, three days in a year were selected randomly. The results indicate that the proposed mode in conjunction with a GAO is a versatile management model for the design and operation of the real pumping station. Modeling results show that optimization with a GAO reduces power consumption by about 15–20%.
Dams are one of the most important hydraulic structures. In view of unrecoverable damages occurring after a dam failure, analyzing a dams’ break is necessary. In this study, a dam located in Iran is considered. According to adjacent tourist and entertainment zones, the breaking of the dam could lead to severe problems for the area and bridges downstream of the river. To investigate the issue, a numerical FORTRAN code based on the 2D finite volume Roe-TVD method on a fixed bed is provided to assess the effects of the dam break. Turbulence terms and dry bed conditions were considered in the code. A numerical wave tank (NWT) with a triangular barrier in the bed was numerically modeled and compared with analytical models to verify the capability of the code. Comparing numerical, experimental and analytical results showed that estimated water level and mass conservation in the numerical model is in good agreement with the experimental data and analytical solutions. The 2D approach used has reduced the cost of computing compared to a 3D approach while obtaining accurate results. The code is finally applied to a full-scale dam-break flood. Six KM of the natural river downstream of the dam, including two bridges, B1 and B2, is considered. Flood flow hydrographs and water level variations at bridges B1 and B2 are presented. The results denoted that bridges B1 and B2 will be flooded after 12 and 21 min, respectively, and are at risk of the potential break. Thus, it is necessary to announce and possibly evacuate the resort area alongside the dam in order to decrease losses.
1 July 2022 in Revista Facultad de Ingeniería Universidad de Antioquia
In this paper, the water pumping regime, as well as the water consumption regime with regard to the required quantities and the example of water consumption, with an emphasis on changes in water volume, are examined. This aims to show the functioning of the regime of water consumption, water pumping, as well as finding functional relationships between the mentioned sizes and the volume of the water reservoir. The analysis focuses on questions such as how and in what way, changes in the onset and duration of pumping, as well as different water consumption regimes affect the size of the reservoir volume. The entire analysis in this paper was done to develop a scientifically innovative, but also applicable mathematical model, which is a contribution to the profession and a good basis for further scientific research to improve the operation of the urban water supply system.
Due to the complexity of calculating the minimum required volume of water tanks and the associated regime of pumping water into the tank depending on the consumption pattern in the water supply systems, finding the functional dependence of these variables is a complex process. The main idea of this paper was to provide a methodology for the calculation of the minimum water tank volume considering all input variables, which could be used in a simple and applicable way in everyday water supply management and engineering. As a final product, a desktop application TankOPT was developed that is easy to run and use on a PC with a user-friendly interface for data entry (data on maximum daily consumption and the pattern of daily water consumption). A software solution was created based on a numerical model that simplifies the usual manual calculations using known spreadsheet software and solves this problem. The solution was determined with combinations of the start and duration of water pumping in the water tank, for which the minimum required volume of the tank is obtained. JavaScript programming language was used to create the app. The use and operation of the application are shown through two hypothetical examples.
Nematodes are among the organisms found in treated water. While generally considered harmless to human health, under certain conditions, they may serve as vectors for pathogenic viruses and bacteria, posing potential risks. Conventional disinfection processes in water treatment can contribute to the inactivation or removal of nematodes, but their effectiveness varies. This study, conducted at a water treatment plant (WTP) in Mashhad, Iran, aimed to determine the optimal dose and contact time of sodium hypochlorite and ozone for enhancing nematode inactivation in the affected surface water. This research combined primary disinfection using sodium hypochlorite at the existing WTP with a pilot ozone injection system to evaluate their individual and combined effectiveness. The results show that sodium hypochlorite at a concentration of 2 mg/L achieved 68% nematode inactivation. At 2.0 mg/L, with a 20 min contact time, ozone disinfection resulted in 39% inactivation. However, the combined application of sodium hypochlorite and ozone significantly improved efficiency, reaching 92% nematode inactivation when sodium hypochlorite and ozone were applied at 2 mg/L and 3 mg/L, respectively, with a 20 min ozone contact time. These findings indicate that, among the disinfection methods examined, the combined use of sodium hypochlorite and ozone is the most effective approach for nematode inactivation in drinking water, offering a promising strategy for improving water quality and safety.
1 January 2020 in World Journal of Environmental Biosciences
Given the increasing growth of population and community’s need for access to resources, such as water and electricity, optimization and management at all sections of the community are necessary, the present study has sought to develop a program according to which, the existing pumps will be turned on during non-peak hours of electricity consumption and the water stored in reservoirs will be used from 6 pm to 11 pm. For this purpose, minimum costs of use of pumps are calculated by presentin