Siavash Khaksar

Dr. Siavash Khaksar

Electrical Engineering, Computing, and Mathematical Sciences, Curtin University, Perth, Western Australia, Australia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2025 in Mining
Verified
Journal Article
Open access
PDF file
Rohan Le RouxRohan Le Roux
Rohan Le Roux
Mohammadali SepehriMohammadali Sepehri
Mohammadali Sepehri
Siavash KhaksarSiavash Khaksar
Siavash Khaksar
Iain MurrayIain Murray
Iain Murray
Slope failures in open-pit mining pose significant operational and safety issues, underscoring the importance of implementing effective stability monitoring frameworks for early hazard detection to allow for timely intervention and risk mitigation. This systematic review presents a comprehensive synthesis of existing and emerging methods and technologies used for slope stability monitoring in open-pit mining, including both remote sensing and in situ methods, as well as advanced technologies, such as Artificial Intelligence (AI), the Internet of Things (IoT), and Wireless Sensor Networks (WSNs). Using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) 2020 guidelines, a total of 49 studies were selected from a collection of four engineering databases, and a comparative analysis was conducted to determine the underlying differences between the various methods for open-pit slope stability monitoring in terms of their performance across key attributes, such as monitoring accuracy, spatial and temporal coverage, operational complexity, and economic viability. Their juxtaposition highlighted the notion that no universally optimal slope stability monitoring system exists, due to a series of compromises that arise as a result of inherent technological limitations and site-specific constraints. Notably, remote sensing methods offer large-scale, non-intrusive monitoring, but are often limited by environmental factors and data acquisition infrequency, whereas in situ methods provide high precision, but suffer from limited spatial coverage and scalability. This review further highlights the capacity of emerging methods and technologies to address these limitations, providing suggestions for future research directions involving the integration of multiple sensing technologies for the enhancement of monitoring capabilities. This study provides a consolidated knowledge base on open-pit slope stability monitoring methods, technologies, and techniques, to guide the development of integrated, cost-effective, and scalable slope monitoring solutions that enhance mine safety and efficiency.

20 October 2021 in JMIR Rehabilitation and Assistive Technologies
Verified
Journal Article
Open access
Siavash KhaksarSiavash Khaksar
Siavash Khaksar
HPHuizhu Pan
Huizhu Pan
BBBita Borazjani
Bita Borazjani
Iain MurrayIain Murray
Iain Murray
Himanshu AgrawalHimanshu Agrawal
Himanshu Agrawal
CWCorrin Walmsley
Corrin Walmsley
Background: Cerebral palsy (CP) is a physical disability that affects movement and posture. Approximately 17 million people worldwide and 34,000 people in Australia are living with CP. In clinical and kinematic research, goniometers and inclinometers are the most commonly used clinical tools to measure joint angles and positions in children with CP. Objective: This paper presents collaborative research between the School of Electrical Engineering, Computing and Mathematical Sciences at Curtin University and a team of clinicians in a multicenter randomized controlled trial involving children with CP. This study aims to develop a digital solution for mass data collection using inertial measurement units (IMUs) and the application of machine learning (ML) to classify the movement features associated with CP to determine the effectiveness of therapy. The results were calculated without the need to measure Euler, quaternion, and joint measurement calculation, reducing the time required to classify the data. Methods: Custom IMUs were developed to record the usual wrist movements of participants in 2 age groups. The first age group consisted of participants approaching 3 years of age, and the second age group consisted of participants approaching 15 years of age. Both groups consisted of participants with and without CP. The IMU data were used to calculate the joint angle of the wrist movement and determine the range of motion. A total of 9 different ML algorithms were used to classify the movement features associated with CP. This classification can also confirm if the current treatment (in this case, the use of wrist extension) is effective. Results: Upon completion of the project, the wrist joint angle was successfully calculated and validated against Vicon motion capture. In addition, the CP movement was classified as a feature using ML on raw IMU data. The Random Forrest algorithm achieved the highest accuracy of 87.75% for the age range approaching 15 years, and C4.5 decision tree achieved the highest accuracy of 89.39% for the age range approaching 3 years. Conclusions: Anecdotal feedback from Minimising Impairment Trial researchers was positive about the potential for IMUs to contribute accurate data about active range of motion, especially in children, for whom goniometric methods are challenging. There may also be potential to use IMUs for continued monitoring of hand movements throughout the day. Trial Registration: Australian New Zealand Clinical Trials Registry (ANZCTR) ACTRN12614001276640, https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=367398; ANZCTR ACTRN12614001275651, https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=367422

9 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Siavash KhaksarSiavash Khaksar
Siavash Khaksar
LCLuke Checker
Luke Checker
BBBita Borazjani
Bita Borazjani
Iain MurrayIain Murray
Iain Murray
Gesture recognition is a mechanism by which a system recognizes an expressive and purposeful action made by a user’s body. Hand-gesture recognition (HGR) is a staple piece of gesture-recognition literature and has been keenly researched over the past 40 years. Over this time, HGR solutions have varied in medium, method, and application. Modern developments in the areas of machine perception have seen the rise of single-camera, skeletal model, hand-gesture identification algorithms, such as media pipe hands (MPH). This paper evaluates the applicability of these modern HGR algorithms within the context of alternative control. Specifically, this is achieved through the development of an HGR-based alternative-control system capable of controlling of a quad-rotor drone. The technical importance of this paper stems from the results produced during the novel and clinically sound evaluation of MPH, alongside the investigatory framework used to develop the final HGR algorithm. The evaluation of MPH highlighted the Z-axis instability of its modelling system which reduced the landmark accuracy of its output from 86.7% to 41.5%. The selection of an appropriate classifier complimented the computationally lightweight nature of MPH whilst compensating for its instability, achieving a classification accuracy of 96.25% for eight single-hand static gestures. The success of the developed HGR algorithm ensured that the proposed alternative-control system could facilitate intuitive, computationally inexpensive, and repeatable drone control without requiring specialised equipment.

6 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SSsana sabry
sana sabry
Siavash KhaksarSiavash Khaksar
Siavash Khaksar
EHEmad Khdhair Hadi
Emad Khdhair Hadi
Himanshu AgrawalHimanshu Agrawal
Himanshu Agrawal
Iain MurrayIain Murray
Iain Murray
Cerebral palsy (CP) is a common reason for human motor ability limitations caused before birth, through infancy or early childhood. Poor head control is one of the most important problems in children with level IV CP and level V CP, which can affect many aspects of children’s lives. The current visual assessment method for measuring head control ability and cervical range of motion (CROM) lacks accuracy and reliability. In this paper, a HeadUp system that is based on a low-cost, 9-axis, inertial measurement unit (IMU) is proposed to capture and evaluate the head control ability for children with CP. The proposed system wirelessly measures CROM in frontal, sagittal, and transverse planes during ordinary life activities. The system is designed to provide real-time, bidirectional communication with an Euler-based, sensor fusion algorithm (SFA) to estimate the head orientation and its control ability tracking. The experimental results for the proposed SFA show high accuracy in noise reduction with faster system response. The system is clinically tested on five typically developing children and five children with CP (age range: 2–5 years). The proposed HeadUp system can be implemented as a head control trainer in an entertaining way to motivate the child with CP to keep their head up.

20 July 2025 in Drones
Verified
Journal Article
Open access
PDF file
LCLuke Checker
Luke Checker
Hui XIEHui XIE
Hui XIE
Siavash KhaksarSiavash Khaksar
Siavash Khaksar
Iain MurrayIain Murray
Iain Murray
Advancements in Unmanned Aerial Vehicle (UAV) technologies have increased exponentially in recent years, with UAV swarm being a key area of interest. UAV swarm overcomes the energy reserve, payload, and single-objective limitations of single UAVs, enabling broader mission scopes. Despite these advantages, UAV swarm has yet to see widespread application within global industry. A leading factor hindering swarm application within industry is the divide that currently exists between the functional capacity of modern UAV swarm systems and the functionality required by legislation. This paper investigates this divide through an overview of global legislative practice, contextualized via a case study of Australia’s UAV regulatory environment. The overview highlighted legislative objectives that coincided with open challenges in the UAV swarm literature. These objectives were then formulated into analysis criteria that assessed whether systems presented sufficient functionality to address legislative concern. A systematic review methodology was used to apply analysis criteria to multi-objective UAV swarm mission planning systems. Analysis focused on multi-objective mission planning systems due to their role in defining the functional capacity of UAV swarms within complex real-world operational environments. This, alongside the popularity of these systems within the modern literature, makes them ideal candidates for defining new enabling technologies that could address the identified areas of weakness. The results of this review highlighted several legislative considerations that remain under-addressed by existing technologies. These findings guided the proposal of enabling technologies to bridge the divide between functional capacity and legislative concern.

8 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Siavash KhaksarSiavash Khaksar
Siavash Khaksar
SPStefanie Pieters
Stefanie Pieters
BBBita Borazjani
Bita Borazjani
JHJoshua Hyde
Joshua Hyde
HBHarrison Booker
Harrison Booker
Amity CampbellAmity Campbell
Amity Campbell
Personal protective equipment (PPE) is an essential key factor in standardizing safety within the workplace. Harsh working environments with long working hours can cause stress on the human body that may lead to musculoskeletal disorder (MSD). MSD refers to injuries that impact the muscles, nerves, joints, and many other human body areas. Most work-related MSD results from hazardous manual tasks involving repetitive, sustained force, or repetitive movements in awkward postures. This paper presents collaborative research from the School of Electrical Engineering and School of Allied Health at Curtin University. The main objective was to develop a framework for posture correction exercises for workers in hostile environments, utilizing inertial measurement units (IMU). The developed system uses IMUs to record the head, back, and pelvis movements of a healthy participant without MSD and determine the range of motion of each joint. A simulation was developed to analyze the participant’s posture to determine whether the posture present would pose an increased risk of MSD with limits to a range of movement set based on the literature. When compared to measurements made by a goniometer, the body movement recorded 94% accuracy and the wrist movement recorded 96% accuracy.