Bernhard Frank

Dr. Bernhard Frank

Michael Ogon Laboratory for Orthopaedic Research, Orthopaedic Hospital Vienna-Speising
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
KKKseniya Khamina
Kseniya Khamina
ADAndreas B. Diendorfer
Andreas B. Diendorfer
SSSusanna Skalicky
Susanna Skalicky
MWMoritz Weigl
Moritz Weigl
MPMarianne Pultar
Marianne Pultar
MHMatthias Hackl
Matthias Hackl
The plasma levels of tissue-specific microRNAs can be used as diagnostic, disease severity and prognostic biomarkers for chronic and acute diseases and drug-induced injury. Thereby, the combination of diverse microRNAs into biomarker signatures using multivariate statistics seems especially powerful from the perspective of tissue and condition specific microRNA shedding into the plasma. Although next-generation sequencing (NGS) technology enables one to analyse circulating microRNAs on a genome-scale level, it suffers from potential biases (e.g., adapter ligation bias) and lacks absolute transcript quantitation as well as tailor-made quality controls. In order to develop a robust NGS discovery assay for genome-scale quantitation of circulating microRNAs, we first evaluated the sensitivity, repeatability and ligation bias of four commercially available small RNA library preparation protocols. The protocol from RealSeq Biosciences was selected based on its performance and usability and coupled with a novel panel of exogenous small RNA spike-in controls to enable quality control and absolute quantitation, thus ensuring comparability of data across independent NGS experiments. The established microRNA Next-Generation-Sequencing Discovery Assay (miND) was validated for its relative accuracy, precision, analytical measurement range and sequencing bias and was considered fit-for-purpose for microRNA biomarker discovery. Summarized, all these criteria were met, and thus, our analytical platform is considered fit-for-purpose for microRNA biomarker discovery from biofluids in the setting of any diagnostic, prognostic or patient stratification need. The established miND assay was tested on serum, cerebrospinal fluid (CSF), synovial fluid (SF) and extracellular vesicles (EV) extracted from cell culture medium of primary cells and proved its potential to be used across different sample types.

17 February 2023 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
GSGilbert Schwarz
Gilbert Schwarz
SSSebastian Simon
Sebastian Simon
JMJennyfer Angel Mitterer
Jennyfer Angel Mitterer
SHStephanie Huber
Stephanie Huber
BFBernhard Frank
Bernhard Frank
JHJochen Hofstaetter
Jochen Hofstaetter
Purpose: Despite advances of three-dimensional imaging pelvic radiographs remain the cornerstone in the evaluation of the hip joint. However, large inter- and intra-rater variabilities were reported due to subjective landmark setting. Artificial intelligence (AI)–powered software applications could improve the reproducibility of pelvic radiograph evaluation by providing standardized measurements. The aim of this study was to evaluate the reliability and agreement of a newly developed AI algorithm for the evaluation of pelvic radiographs. Methods: Three-hundred pelvic radiographs from 280 patients with different degrees of acetabular coverage and osteoarthritis (Tönnis Grade 0 to 3) were evaluated. Reliability and agreement between manual measurements and the outputs of the AI software were assessed for the lateral-center-edge (LCE) angle, neck-shaft angle, sharp angle, acetabular index, as well as the femoral head extrusion index. Results: The AI software provided reliable results in 94.3% (283/300). The ICC values ranged between 0.73 for the Acetabular Index to 0.80 for the LCE Angle. Agreement between readers and AI outputs, given by the standard error of measurement (SEM), was good for hips with normal coverage (LCE-SEM: 3.4°) and no osteoarthritis (LCE-SEM: 3.3°) and worse for hips with undercoverage (LCE-SEM: 5.2°) or severe osteoarthritis (LCE-SEM: 5.1°). Conclusion: AI-powered applications are a reliable alternative to manual evaluation of pelvic radiographs. While being accurate for patients with normal acetabular coverage and mild signs of osteoarthritis, it needs improvement in the evaluation of patients with hip dysplasia and severe osteoarthritis.

10 July 2024 in Bone & Joint Research
Verified
Journal Article
Open access
PDF file
SGSusana Gardete-Hartmann
Susana Gardete-Hartmann
JMJennyfer Angel Mitterer
Jennyfer Angel Mitterer
SSSUJEESH SEBASTIAN
SUJEESH SEBASTIAN
BFBernhard Frank
Bernhard Frank
SSSebastian Simon
Sebastian Simon
JHJochen Hofstaetter
Jochen Hofstaetter
Aims: This study aimed to evaluate the BioFire Joint Infection (JI) Panel in cases of hip and knee periprosthetic joint infection (PJI) where conventional microbiology is unclear, and to assess its role as a complementary intraoperative diagnostic tool.Methods: Five groups representing common microbiological scenarios in hip and knee revision arthroplasty were selected from our arthroplasty registry, prospectively maintained PJI databases, and biobank: 1) unexpected-negative cultures (UNCs), 2) unexpected-positive cultures (UPCs), 3) single-positive intraoperative cultures (SPCs), and 4) clearly septic and 5) aseptic cases. In total, 268 archived synovial fluid samples from 195 patients who underwent acute/chronic revision total hip or knee arthroplasty were included. Cases were classified according to the International Consensus Meeting 2018 criteria. JI panel evaluation of synovial fluid was performed, and the results were compared with cultures.Results: The JI panel detected microorganisms in 7/48 (14.5%) and 15/67 (22.4%) cases related to UNCs and SPCs, respectively, but not in cases of UPCs. The correlation between JI panel detection and infection classification criteria for early/late acute and chronic PJI was 46.6%, 73%, and 40%, respectively. Overall, the JI panel identified 12.6% additional microorganisms and three new species. The JI panel pathogen identification showed a sensitivity and specificity of 41.4% (95% confidence interval (CI) 33.7 to 49.5) and 91.1% (95% CI 84.7 to 94.9), respectively. In total, 19/195 (9.7%) could have been managed differently and more accurately upon JI panel evaluation.Conclusion: Despite its microbial limitation, JI panel demonstrated clinical usefulness by complementing the traditional methods based on multiple cultures, particularly in PJI with unclear microbiological results.Cite this article: Bone Joint Res 2024;13(7):353–361.

1 June 2021 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
BFBernhard Frank
Bernhard Frank
AAAlexander Aichmair
Alexander Aichmair
SSSebastian Simon
Sebastian Simon
GSGilbert M. Schwarz
Gilbert M. Schwarz
MDMartin Dominkus
Martin Dominkus
JHJochen G. Hofstaetter
Jochen G. Hofstaetter

29 July 2021 in Biomedicines
Verified
Journal Article
Open access
PDF file
LLLukas Lüftinger
Lukas Lüftinger
IFInês Ferreira
Inês Ferreira
BFBernhard Frank
Bernhard Frank
SBStephan Beisken
Stephan Beisken
JWJohannes Weinberger
Johannes Weinberger
AMArne Materna
Arne Materna
Joint replacement surgeries are one of the most frequent medical interventions globally. Infections of prosthetic joints are a major health challenge and typically require prolonged or even indefinite antibiotic treatment. As multidrug-resistant pathogens continue to rise globally, novel diagnostics are critical to ensure appropriate treatment and help with prosthetic joint infections (PJI) management. To this end, recent studies have shown the potential of molecular methods such as next-generation sequencing to complement established phenotypic, culture-based methods. Together with advanced bioinformatics approaches, next-generation sequencing can provide comprehensive information on pathogen identity as well as antimicrobial susceptibility, potentially enabling rapid diagnosis and targeted therapy of PJIs. In this review, we summarize current developments in next generation sequencing based predictive antibiotic susceptibility testing and discuss potential and limitations for common PJI pathogens.

18 March 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SSSebastian Simon
Sebastian Simon
BFBernhard Frank
Bernhard Frank
AAAlexander Aichmair
Alexander Aichmair
PMPhilip P. Manolopoulos
Philip P. Manolopoulos
MDMartin Dominkus
Martin Dominkus
JHJochen Hofstaetter
Jochen Hofstaetter
The aim of this study was to evaluate the number of primary and revision total joint arthroplasties (TJA/rTJA) in 2020 compared to 2019. Specifically, the first and the second waves of the COVID-19 pandemic were evaluated as well as the pre-operative COVID-19 test. A cross-sectional single-center study of our prospectively maintained institutional arthroplasty registry was performed. The first COVID-19 wave and the second COVID-19 wave led to a socioeconomic lockdown in 2020. Performed surgeries, cause of revision, age, gender, and American Society of Anesthesiologists-level were analyzed. Preoperative COVID-19 testing was evaluated and nationwide COVID-19 data were compared to other countries. In 2020, there was a decrease by 16.2% in primary and revision TJAs of the hip and knee compared to 2019. We observed a reduction of 15.8% in primary TJAs and a reduction of 18.6% on rTJAs in 2020 compared to 2019. There is an incline in total hip arthroplasties (THAs) and a decline in total knee arthroplasties (TKAs) comparing 2019 to 2020. During the first wave, there was a reduction in performed primary TJAs of 86%. During the second wave, no changes were observed. This is the first study quantifying the impact of the COVID-19 pandemic on primary and revision TJAs regarding the first and second wave.