Wang Jingfu

Dr. Wang Jingfu


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XZXinxin Zhang
Xinxin Zhang
CMCao Min
Cao Min
XYXiaoyu Yang
Xiaoyu Yang
HGHang Guo
Hang Guo
WJWang Jingfu
Wang Jingfu
The organic Rankine cycle (ORC) is a popular technology used in waste heat recovery and low-grade heat utilization, which are two important measures to solve the problems brought by the energy crisis. The economic performance of ORC system is an important factor affecting its application and development. Therefore, the economic analysis of ORC is of great significance. In this study, R123 and R245fa, two frequently-used working fluids during the transition period, were selected for calculating and analyzing the economic performance of an ORC used for recovery of waste heat with a low flow rate and medium-low temperature. Five traditional economic indicators, namely total cost, net earnings, payback period, return on investment, levelized energy cost, and present value of total profit in system service life, which is a relatively new indicator, were used to establish the economic analysis model of ORC. The variation effects of evaporation temperature, condensation temperature of working fluid, flue gas inlet temperature, and mass flow rate of flue gas on the above six economic indicators were analyzed. The results show that the optimal evaporation temperature of R123 is 125 °C, the optimal condensation temperature is 33 °C, and the optimal heat source temperature is 217 °C. For R245fa, the optimal evaporation temperature is 122 °C, the optimal condensation temperature is 27 °C, and the optimal heat source temperature is 177 °C. The economic performance of an ORC demonstration project was reported and used for comparison with the estimation and analysis. It was found that the single screw expander has an excellent economy performance, which greatly reduces the proportion of expander cost in the ORC system.

26 April 2021 in ACS Omega
Verified
Journal Article
Open access
XZXiaolei Zhang
Xiaolei Zhang
WJWang Jingfu
Wang Jingfu
YCying chen
ying chen
CLConghao Li
Conghao Li
Ammonia (NH3) is not only expected to be used as a hydrogen energy carrier but also expected to become a carbon-free fuel. Methane (CH4) can be used as a combustion enhancer for improving the combustion intensity of NH3. In addition, it is important to understand the flame characteristics of NH3–air at elevated pressures and temperatures. The laminar flame speed of NH3–CH4–air is numerically investigated, where the mole fraction of CH4 ranges from 0 to 50% in binary fuels and the pressure and initial temperature are up to 10 atm and 1000 K, respectively. The calculated value from the Okafor mechanism is in excellent agreement with experimental data. The CH4 in the fuel affects the flame speed by changing the main species of free radicals in the flame; the high pressure not only increases the rate-limiting reaction rate in the flame but also reduces the amount of H, O, and OH radicals in the flame, so as to restrain the propagation of the flame. At a higher initial temperature, the faster flame speed is mainly due to the higher adiabatic flame temperature. The laminar flame speed correlation equation has a consistent trend with the simulation results, though with a slight underestimation at higher pressures and temperatures. It is a more effective way to calculate the laminar flame speeds of NH3–air for a given pressure and temperature.

20 April 2016 in Energies
Verified
Journal Article
Open access
PDF file
GLGaosheng Li
Gaosheng Li
HZHongguang Zhang
Hongguang Zhang
FYFubin Yang
Fubin Yang
SSSongsong Song
Songsong Song
YCYing Chang
Ying Chang
BYBaofeng Yao
Baofeng Yao
A novel free piston expander-linear generator (FPE-LG) integrated unit was proposed to recover waste heat efficiently from vehicle engine. This integrated unit can be used in a small-scale Organic Rankine Cycle (ORC) system and can directly convert the thermodynamic energy of working fluid into electric energy. The conceptual design of the free piston expander (FPE) was introduced and discussed. A cam plate and the corresponding valve train were used to control the inlet and outlet valve timing of the FPE. The working principle of the FPE-LG was proven to be feasible using an air test rig. The indicated efficiency of the FPE was obtained from the p–V indicator diagram. The dynamic characteristics of the in-cylinder flow field during the intake and exhaust processes of the FPE were analyzed based on Fluent software and 3D numerical simulation models using a computation fluid dynamics method. Results show that the indicated efficiency of the FPE can reach 66.2% and the maximal electric power output of the FPE-LG can reach 22.7 W when the working frequency is 3 Hz and intake pressure is 0.2 MPa. Two large-scale vortices are formed during the intake process because of the non-uniform distribution of velocity and pressure. The vortex flow will convert pressure energy and kinetic energy into thermodynamic energy for the working fluid, which weakens the power capacity of the working fluid.

20 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
XZXinxin Zhang
Xinxin Zhang
ZAzhang Ag
zhang Ag
CMCao Min
Cao Min
WJWang Jingfu
Wang Jingfu
YWYu-Ting Wu
Yu-Ting Wu
CMChongfang Ma
Chongfang Ma
The organic Rankine cycle (ORC) is a popular technology used in waste heat recovery and medium-low-temperature heat utilization. Working fluid plays a very important role in ORC. The selection of working fluid can greatly affect the efficiency, the operation condition, the impact on the environment, and the economic feasibility of ORC. The expander is a key device in ORC. As a novel expander, single-screw expanders have been becoming a research focus in the above two areas because of their many good characteristics. One of the advantages of single-screw configurations is that they can conduct a vapor–liquid two-phase expansion. Therefore, in order to give full play to this advantage, a working fluid selection for ORC using a single-screw expander was conducted in this paper. Three indicators, namely, net work output, thermal efficiency, and heat exchange load of condenser, were used to analyze the performance of an ORC system. Through calculation and analysis, it can be seen that an ORC system that uses a single-screw expander and undergoes a vapor–liquid two-phase expansion is able to obtain a higher thermal efficiency, higher net work output, and a smaller heat exchange load of the condenser. Regardless of whether isentropic efficiency of the expander is considered or not, cis-butene may be the best candidate for working in subcritical cycles. HFO working fluids are more suitable for working in transcritical cycles, and HFO-1234ze(E) may be the best.

22 December 2016 in Energies
Verified
Journal Article
Open access
PDF file
GLGuoqiang Li
Guoqiang Li
YWYu-Ting Wu
Yu-Ting Wu
YZYeqiang Zhang
Yeqiang Zhang
RZRuiping Zhi
Ruiping Zhi
WJWang Jingfu
Wang Jingfu
CMChongfang Ma
Chongfang Ma
A single-screw expander with 195 mm diameter is developed to recover pressure energy in letdown stations. An experiment system is established using compressed air as a working fluid instead of natural gas. Experiments are conducted via measurements for important parameters, such as inlet and outlet temperature and pressure, volume flow rate and power output. The influence of inlet pressure and rotational speed on the performance are also analyzed. Results indicate that the single-screw expander achieved good output characteristics, in which 2800 rpm is considered the best working speed. The maximum volumetric efficiency, isentropic efficiency, overall efficiency, and the lowest air-consumption are 51.1 kW, 83.5%, 66.4%, 62.2%, and 44.1 kg/(kW·h), respectively. If a single-screw expander is adopted in a pressure energy recovery system applied in a certain domestic natural gas letdown station, the isentropic efficiency of the single-screw expander and overall efficiency of the system are found to be 66.4% and 62.2%, respectively. Then the system performances are predicted, in which the lowest methane consumption is 27.3 kg/(kW·h). The installed capacity is estimated as 204.7 kW, and the annual power generation is 43.3 MWh. In the next stage, a pressure energy recovery demonstration project that recycles natural gas will be established within China, with the single-screw expander serving as the power machine.

17 April 2017 in Energies
Verified
Journal Article
Open access
PDF file
SSSongsong Song
Songsong Song
HZHongguang Zhang
Hongguang Zhang
RZRui Zhao
Rui Zhao
FMFanxiao Meng
Fanxiao Meng
HLHongda Liu
Hongda Liu
BYBaofeng Yao
Baofeng Yao
The organic Rankine cycle (ORC) can be used to recover the waste heat from a stationary compressed natural gas (CNG) engine. However, the exhaust energy rate varies with engine load, which can influence the operating performance of the ORC system, therefore, it is necessary to study the running state of the ORC system. In this paper, first, the numerical simulation model of the ORC system is built by using GT-Suite software, with R245fa selected as the working fluid of the ORC system. The boundary conditions of the numerical simulation model are specified according to the measured data obtained by the stationary CNG engine test. Subsequently, the power output and dynamic characteristics of expander are analyzed to determine the running state of the ORC system. Investigations indicate that the fluctuation of refrigerant mass flow rate in the expander is obvious in the engine’s low-load regions (from 20% engine load to 40% engine load). The performances of ORC system and stationary CNG engine-ORC combined system (combined system) are finally investigated, respectively. The results show that the thermal efficiency of the combined system can be increased by a maximum 5.0% (at the engine rated condition), while the brake specific fuel consumption (BSFC) can be reduced by a maximum 4.0% (at the engine rated condition).