Harold Parks

Dr. Harold Parks

NRC Metrology Research Center, National Research Council, Ottawa, ON K1A 0R6, Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2014 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
HPHarold Parks
Harold Parks
JFJames E. Faller
James E. Faller
We present a detailed account of our 2004 experiment to measure the Newtonian constant of gravitation with a suspended laser interferometer. The apparatus consists of two simple pendulums hanging from a common support. Each pendulum has a length of 72 cm and their separation is 34 cm. A mirror is embedded in each pendulum bob, which then in combination form a Fabry–Perot cavity. A laser locked to the cavity measures the change in pendulum separation as the gravitational field is modulated due to the displacement of four 120 kg tungsten masses.

18 March 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ESEddy So
Eddy So
RVRob Verhoeven
Rob Verhoeven
BSBart Simons
Bart Simons
HPHarold Parks
Harold Parks
DADave Angelo
Dave Angelo
An overview of the development and performance of a special high-precision multiratio three-stage current transformer and its application for loss measurements of extra high voltage. Three-phase shunt reactors with test voltages up to a phase voltage of 1100 kV at royal SMIT transformers are presented and discussed. It features current ratios of 500 A/1 A, 400 A/1 A, 300 A/1 A, 200 A/1 A, and 100 A/1 A with ratio errors within 3 x 10⁻⁶ in both magnitude and phase with burdens up to 1.0 Ω and at power frequencies of 50-60 Hz.

19 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
RGRefat Ghunem
Refat Ghunem
YHYazid Hadjadj
Yazid Hadjadj
HPHarold Parks
Harold Parks
This paper discusses the lessons learned about fillers that are added to silicone rubber insulation housing composites, in order to improve the erosion resistance against the dry-band arcing are presented and common perceptions. Common practices that employ alumina tri-hydrate are reviewed, including the additional influential effect of the water of hydration in the suppression of the dry-band arcing. The effect of the water of hydration is shown to be dependent on various factors, such as the hydrated filler level and the type of the hydrated filler. More recent paradigms in which hydrated fillers have not been employed are also reviewed. Volume and shield actions of fillers are essential aspects that need to be understood in the design of silicone rubber insulation housing composites for new applications such as HVDC. In addition, the thermal degradation mechanisms of silicone rubber and the corresponding suppression effects of the added fillers are summarized.

25 December 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BDBranislav Djokic
Branislav Djokic
HPHarold Parks
Harold Parks
The paper describes the recent development of a system for calibration of electrical instruments with harmonics measurement capability, such as revenue meters and power analyzers, under non-sinusoidal test conditions at National Research Council (NRC) Canada. The improvements implemented with respect to an earlier NRC calibration system are aimed at increasing the calibration accuracy in a wider frequency range.

19 May 2021 in IEEE Instrumentation & Measurement Magazine
Verified
Journal Article
Closed access
BDBranislav Djokic
Branislav Djokic
HPHarold Parks
Harold Parks
Electric power systems have been designed to operate under sinusoidal voltage and current conditions at power frequencies, mainly 50 Hz and 60 Hz, and by far most electrical energy transmission occurs at 50 Hz and 60 Hz. Electric utilities are responsible for providing a sinusoidal voltage to their residential, commercial and industrial customers. The customers are, on their side, responsible for not causing excessive distortion of the voltage and current in the system. Since voltage and current, in practice, are periodical but not exactly sinusoidal, they contain higher frequency components—harmonies—in addition to the fundamental frequency component (50 Hz or 60 Hz).

2 January 2016 in NCSLI Measure
Verified
Journal Article
Closed access
HPHarold Parks
Harold Parks
High-voltage DC measurements, from 10 kV up to several hundred kV, are usually traceable through resistive dividers which have a divider ratio on the order of 10,000–100,000. The reference step method [ 3 M. D. Early, M. Sira, B.-O. Andersson, L. A. Christian, O. Gunnarsson, K.-E. Rydler, and J. Streit, “A simple build-up method for the DC voltage scale of a source,” IEEE Trans. Instrum. Meas., vol. 62, no. 6, pp. 1600–1607, June 2013. [Crossref], [Web of Science ®] [Google Scholar] ] provides a highly accurate ratiometric method of calibrating 1,000 V calibrators across a wide range of voltages. We adapt this method for measuring the ratio of high-voltage dividers at low (≤1,000 V) voltages as a first step to establishing traceability at high voltages.