Branislav Djokic

Branislav Djokic

Auto-generated profile, based on publicly available information

Branislav Djokic

Regional Director, North America

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2016 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BDBranislav V. Djokic
Branislav V. Djokic
This paper describes improvements of a calibration system for Rogowski coils at high pulsed currents developed at the National Research Council of Canada. This system is designed to provide traceable calibrations of Rogowski coils and weld current meters for users in resistance welding industry, secondary laboratories, and other organizations. The accuracy of the improved calibration system is related to the improved measurement of harmonic content of the test pulsed currents and is estimated for individual tests.

1 January 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BDBranislav Djokic
Branislav Djokic
HPHarold Parks
Harold Parks

25 December 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BDBranislav Djokic
Branislav Djokic
HPHarold Parks
Harold Parks
The paper describes the recent development of a system for calibration of electrical instruments with harmonics measurement capability, such as revenue meters and power analyzers, under non-sinusoidal test conditions at National Research Council (NRC) Canada. The improvements implemented with respect to an earlier NRC calibration system are aimed at increasing the calibration accuracy in a wider frequency range.

1 June 2009 in NCSLI Measure
Verified
Journal Article
Closed access
BDBranislav Djokić
Branislav Djokić
In spite of a large number of publications on new Rogowski coil designs and applications, there are relatively few papers that deal with their calibration, and even fewer that address the traceability of these calibrations. This paper describes some of the improvements in the design and performance of Rogowski coils. It focuses on the calibration methods and the traceability required by more demanding applications of the improved Rogowski coil. An overview of the calibration capabilities regarding current and frequency ranges is presented. The best uncertainties (k = 2) of the advanced calibration systems described in the paper are estimated to be better than 50 μA/A for magnitude and 50 μrad for phase, at power frequencies. The uncertainties increase with frequency and current. The capability of calibration systems to generate high currents decreases with increasing frequency.

11 August 2016
Verified
Conference Paper
Closed access
DJDavid Jarry-Bolduc
David Jarry-Bolduc
BDBranislav Djokic
Branislav Djokic
This paper describes measurements of sudden three-phase short-circuit currents of hydro generators by means of Rogowski coils conducted on-site by Hydro-Québec, and the evaluation of related measurement uncertainties obtained from high-accuracy calibration of Rogowski coils using digital sampling at National Research Council (NRC) of Canada.

19 May 2021 in IEEE Instrumentation & Measurement Magazine
Verified
Journal Article
Closed access
BDBranislav Djokic
Branislav Djokic
HPHarold Parks
Harold Parks
Electric power systems have been designed to operate under sinusoidal voltage and current conditions at power frequencies, mainly 50 Hz and 60 Hz, and by far most electrical energy transmission occurs at 50 Hz and 60 Hz. Electric utilities are responsible for providing a sinusoidal voltage to their residential, commercial and industrial customers. The customers are, on their side, responsible for not causing excessive distortion of the voltage and current in the system. Since voltage and current, in practice, are periodical but not exactly sinusoidal, they contain higher frequency components—harmonies—in addition to the fundamental frequency component (50 Hz or 60 Hz).