Liam Young

Mr. Liam Young

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Journal of Hepatology
Verified
Journal Article
Open access
ESEmmanuel Anandraj Selvaraj
Emmanuel Anandraj Selvaraj
FMFerenc Emil Mózes
Ferenc Emil Mózes
AJArjun Narayan Ajmer Jayaswal
Arjun Narayan Ajmer Jayaswal
MZMohammad Hadi Zafarmand
Mohammad Hadi Zafarmand
YVYasaman Vali
Yasaman Vali
LILITMUS Investigators
LITMUS Investigators
Vibration-controlled transient elastography (VCTE), point shear wave elastography (pSWE), 2-dimensional shear wave elastography (2DSWE), magnetic resonance elastography (MRE), and magnetic resonance imaging (MRI) have been proposed as non-invasive tests for patients with non-alcoholic fatty liver disease (NAFLD). This study evaluated their diagnostic accuracy for liver fibrosis and non-alcoholic steatohepatitis (NASH). PubMED/MEDLINE, EMBASE and the Cochrane Library were searched for studies examining the diagnostic accuracy of these index tests, against histology as the reference standard, in adult patients with NAFLD. Two authors independently screened and assessed methodological quality of studies and extracted data. Summary estimates of sensitivity, specificity and area under the curve (sAUC) were calculated for fibrosis stages and NASH, using a random effects bivariate logit-normal model. We included 82 studies (14,609 patients). Meta-analysis for diagnosing fibrosis stages was possible in 53 VCTE, 11 MRE, 12 pSWE and 4 2DSWE studies, and for diagnosing NASH in 4 MRE studies. sAUC for diagnosis of significant fibrosis were: 0.83 for VCTE, 0.91 for MRE, 0.86 for pSWE and 0.75 for 2DSWE. sAUC for diagnosis of advanced fibrosis were: 0.85 for VCTE, 0.92 for MRE, 0.89 for pSWE and 0.72 for 2DSWE. sAUC for diagnosis of cirrhosis were: 0.89 for VCTE, 0.90 for MRE, 0.90 for pSWE and 0.88 for 2DSWE. MRE had sAUC of 0.83 for diagnosis of NASH. Three (4%) studies reported intention-to-diagnose analyses and 15 (18%) studies reported diagnostic accuracy against pre-specified cut-offs. When elastography index tests are acquired successfully, they have acceptable diagnostic accuracy for advanced fibrosis and cirrhosis. The potential clinical impact of these index tests cannot be assessed fully as intention-to-diagnose analyses and validation of pre-specified thresholds are lacking. Non-invasive tests that measure liver stiffness or use magnetic resonance imaging (MRI) have been suggested as alternatives to liver biopsy for assessing the severity of liver scarring (fibrosis) and fatty inflammation (steatohepatitis) in patients with non-alcoholic fatty liver disease (NAFLD). In this study, we summarise the results of previously published studies on how accurately these non-invasive tests can diagnose liver fibrosis and inflammation, using liver biopsy as the reference. We found that some techniques that measure liver stiffness had a good performance for the diagnosis of severe liver scarring.

26 October 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LVLadislav Valkovič
Ladislav Valkovič
IDIulius Dragonu
Iulius Dragonu
SASalam Almujayyaz
Salam Almujayyaz
ABAlex Batzakis
Alex Batzakis
LYLiam Young
Liam Young
CRChristopher T. Rodgers
Christopher T. Rodgers
Cardiac phosphorus magnetic resonance spectroscopy (31P-MRS) provides unique insight into the mechanisms of heart failure. Yet, clinical applications have been hindered by the restricted sensitivity of the surface radiofrequency-coils normally used. These permit the analysis of spectra only from the interventricular septum, or large volumes of myocardium, which may not be meaningful in focal disease. Löring et al. recently presented a prototype whole-body (52 cm diameter) transmit/receive birdcage coil for 31P at 7T. We now present a new, easily-removable, whole-body 31P transmit radiofrequency-coil built into a patient-bed extension combined with a 16-element receive array for cardiac 31P-MRS. A fully-removable (55 cm diameter) birdcage transmit coil was combined with a 16-element receive array on a Magnetom 7T scanner (Siemens, Germany). Electro-magnetic field simulations and phantom tests of the setup were performed. In vivo maps of B1+, metabolite signals, and saturation-band efficiency were acquired across the torsos of eight volunteers. The combined (volume-transmit, local receive array) setup increased signal-to-noise ratio 2.6-fold 10 cm below the array (depth of the interventricular septum) compared to using the birdcage coil in transceiver mode. The simulated coefficient of variation for B1+ of the whole-body coil across the heart was 46.7% (surface coil 129.0%); and the in vivo measured value was 38.4%. Metabolite images of 2,3-diphosphoglycerate clearly resolved the ventricular blood pools, and muscle tissue was visible in phosphocreatine (PCr) maps. Amplitude-modulated saturation bands achieved 71±4% suppression of phosphocreatine PCr in chest-wall muscles. Subjects reported they were comfortable. This easy-to-assemble, volume-transmit, local receive array coil combination significantly improves the homogeneity and field-of-view for metabolic imaging of the human heart at 7T.

Verified
Journal Article
Open access
PDF file
TPThomas Prudhomme
Thomas Prudhomme
JMJohn Mulvey
John Mulvey
LYLiam Young
Liam Young
BMBenoît Mesnard
Benoît Mesnard
MFMaria Letizia Lo Faro
Maria Letizia Lo Faro
JBJulien Branchereau
Julien Branchereau
Maintaining organ viability between donation and transplantation is of critical importance for optimal graft function and survival. To date in pancreas transplantation, static cold storage (SCS) is the most widely practiced method of organ preservation. The first experiments in ex vivo perfusion of the pancreas were performed at the beginning of the 20th century. These perfusions led to organ oedema, hemorrhage, and venous congestion after revascularization. Despite these early hurdles, a number of factors now favor the use of perfusion during preservation: the encouraging results of HMP in kidney transplantation, the development of new perfusion solutions, and the development of organ perfusion machines for the lung, heart, kidneys and liver. This has led to a resurgence of research in machine perfusion for whole organ pancreas preservation. This review highlights the ischemia-reperfusion injuries assessment during ex vivo pancreas perfusion, both for assessment in pre-clinical experimental models as well for future use in the clinic. We evaluated perfusion dynamics, oedema assessment, especially by impedance analysis and MRI, whole organ oxygen consumption, tissue oxygen tension, metabolite concentrations in tissue and perfusate, mitochondrial respiration, cell death, especially by histology, total cell free DNA, caspase activation, and exocrine and endocrine assessment.

29 June 2023 in JHEP Reports
Verified
Journal Article
Open access
RVRaj Vuppalanchi
Raj Vuppalanchi
VAVijay Are
Vijay Are
ATAlison Telford
Alison Telford
LYLiam Young
Liam Young
SMSofia Mouchti
Sofia Mouchti
NCNaga Chalasani
Naga Chalasani
Magnetic resonance cholangiopancreatography (MRCP) for evaluation of biliary disease currently relies on subjective assessment with limited prognostic value because of the lack of quantitative metrics. Artificial intelligence-enabled quantitative MRCP (MRCP+) is a novel technique that segments biliary anatomy and provides quantitative biliary tree metrics. This study investigated the utility of MRCP+ as a prognostic tool for the prediction of clinical outcomes in primary sclerosing cholangitis (PSC). MRCP images of patients with PSC were post-processed using MRCP+ software. The duration between the MRCP and clinical event (liver transplantation or death) was calculated. Survival analysis and stepwise Cox regression were performed to investigate the optimal combination of MRCP+ metrics for the prediction of clinical outcomes. The resulting risk score was validated in a separate validation cohort and compared with an existing prognostic score (Mayo risk score). In this retrospective study, 102 patients were included in a training cohort and a separate 50 patients formed a validation cohort. Between the two cohorts, 34 patients developed clinical outcomes over a median duration of 3 years (23 liver transplantations and 11 deaths). The proportion of bile ducts with diameter 3–5 mm, total bilirubin, and aspartate aminotransferase were independently associated with transplant-free survival. Combined as a risk score, the overall discriminative performance of the MRCP+ risk score (M+BA) was excellent; area under the receiver operator curve 0.86 (95% CI: 0.77, 0.95) at predicting clinical outcomes in the validation cohort with a hazard ratio 5.8 (95% CI: 1.5, 22.1). This was superior to the Mayo risk score. A composite score combining MRCP+ with total bilirubin and aspartate aminotransferase (M+BA) identified PSC patients at high risk of liver transplantation or death. Prospective studies are warranted to evaluate the clinical utility of this novel prognostic tool. Primary sclerosis cholangitis (PSC) is a disease of the biliary tree where inflammation and fibrosis cause areas of narrowing (strictures) and expansion (dilatations) within the biliary ducts leading to liver failure and/or cancer (cholangiocarcinoma). In this study, we demonstrate that quantitative assessment of the biliary tree can better identify patients with PSC who are at high risk of either death or liver transplantation than a current blood-based risk score (Mayo risk score).

9 December 2021 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
CEConnor Ellis
Connor Ellis
Juan PellicoJuan Pellico
Juan Pellico
LYLiam Young
Liam Young
JMJack J. Miller
Jack J. Miller
JDJason J. Davis
Jason J. Davis
The dominant Curie effect underpinning relaxivity enhancements in T2 has been systematically tuned through paramagnetic loading density. This results in the optimisation of acquired MR image contrast, and facilitates effective high field imaging.

17 July 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LYLiam Young
Liam Young
CCCarlo D. L. Ceresa
Carlo D. L. Ceresa
FMFerenc E. Mózes
Ferenc E. Mózes
JEJane Ellis
Jane Ellis
LVLadislav Valkovič
Ladislav Valkovič
CRChristopher T. Rodgers
Christopher T. Rodgers
Purpose: A shortage of suitable donor livers is driving increased use of higher risk livers for transplantation. However, current biomarkers are not sensitive and specific enough to predict posttransplant liver function. This is limiting the expansion of the donor pool. Therefore, better noninvasive tests are required to determine which livers will function following implantation and hence can be safely transplanted. This study assesses the temperature sensitivity of proton density fat fraction and relaxometry parameters and examines their potential for assessment of liver function ex vivo.Methods: Six ex vivo human livers were scanned during static cold storage following normothermic machine perfusion. Proton density fat fraction, T1, T2, andwere measured repeatedly during cooling on ice. Temperature corrections were derived from these measurements for the parameters that showed significant variation with temperature.Results: Strong linear temperature sensitivities were observed for proton density fat fraction (R2= 0.61,P< .001) and T1(R2= 0.78,P< .001). Temperature correction according to a linear model reduced the coefficient of repeatability in these measurements by 41% and 36%, respectively. No temperature dependence was observed in T2ormeasurements. Comparing livers deemed functional and nonfunctional during normothermic machine perfusion by hemodynamic and biochemical criteria, T1differed significantly: 516 ± 50 ms for functional versus 679 ± 60 ms for nonfunctional,P= .02.Conclusion: Temperature correction is essential for robust measurement of proton density fat fraction and T1in cold‐stored human livers. These parameters may provide a noninvasive measure of viability for transplantation.