Objective: Fragmented QRS (fQRS) is an accessible biomarker and indication of myocardial scarring that can be detected from the electrocardiogram (ECG). Nowadays, fQRS scoring is done on a visual basis, which is time-consuming and leads to subjective results. This study proposes an automated method to detect and quantify fQRS in a continuous way using features extracted from Variational Mode Decomposition (VMD) and Phase-Rectified Signal Averaging (PRSA). Methods: In the proposed framework, QRS complexes in the ECG signals were first segmented using VMD. Then, 10 VMD- and PRSA-based features were computed and fed into well-known classifiers such as Support Vector Machine (SVM), K-nearest neighbors (KNN), Naive Bayesian (NB), and TreeBagger (TB) in order to compare their performance. The proposed method was evaluated with 12-lead ECG data of 616 patients from the University Hospitals Leuven. The presence of fQRS in each ECG lead was scored by five raters. Both detection and quantification of fQRS could be achieved in this way. Results: The experimental results indicated that the proposed method achieved AUC values of 0.95, 0.94, 0.90, and 0.89 using SVM, KNN, NB and TB classifiers respectively for detecting QRS fragmentation. Assessment of quantification performance was done by comparing the fQRS score with the total score, obtained by summing the scores from the individual raters. Results showed that the fQRS score clearly correlated with this estimate of fQRS certainty. Conclusion: The proposed method obtained good results in both fQRS detection and quantification, and is a novel way of assessing the certainty of QRS fragmentation in the ECG signal.
The automated classification of cognitive workload tasks based on the analysis of multi-channel EEG signals is vital for human–computer interface (HCI) applications. In this paper, we propose a computerized approach for categorizing mental-arithmetic-based cognitive workload tasks using multi-channel electroencephalogram (EEG) signals. The approach evaluates various entropy features, such as the approximation entropy, sample entropy, permutation entropy, dispersion entropy, and slope entropy, from each channel of the EEG signal. These features were fed to various recurrent neural network (RNN) models, such as long-short term memory (LSTM), bidirectional LSTM (BLSTM), and gated recurrent unit (GRU), for the automated classification of mental-arithmetic-based cognitive workload tasks. Two cognitive workload classification strategies (bad mental arithmetic calculation (BMAC) vs. good mental arithmetic calculation (GMAC); and before mental arithmetic calculation (BFMAC) vs. during mental arithmetic calculation (DMAC)) are considered in this work. The approach was evaluated using the publicly available mental arithmetic task-based EEG database. The results reveal that our proposed approach obtained classification accuracy values of 99.81%, 99.43%, and 99.81%, using the LSTM, BLSTM, and GRU-based RNN classifiers, respectively for the BMAC vs. GMAC cognitive workload classification strategy using all entropy features and a 10-fold cross-validation (CV) technique. The slope entropy features combined with each RNN-based model obtained higher classification accuracy compared with other entropy features for the classification of the BMAC vs. GMAC task. We obtained the average classification accuracy values of 99.39%, 99.44%, and 99.63% for the classification of the BFMAC vs. DMAC tasks, using the LSTM, BLSTM, and GRU classifiers with all entropy features and a hold-out CV scheme. Our developed automated mental arithmetic task system is ready to be tested with more databases for real-world applications.
With the increasing number of sensors/channels, hand gesture recognition from multiple channels has attracted the attention of the researchers in recent years. The analysis of a variety of gestures is still a challenging task in real-time applications such as in wearable devices because of the large number of channels used. This paper proposes a tensor-based approach using multilinear singular value decomposition (MLSVD) for hand gesture recognition where all available channels were used during training whereas only a single channel was used for recognition of new gestures. Tensor decompositions have very limited use in gesture recognition using surface Electromyography (sEMG) despite these signals naturally have multi-way structures. The sEMG data of different subjects were first segmented to reshape it as a fourth-order tensor of the form channels × time × gestures × subjects. The MLSVD was applied to model the tensor and extract features, which were then fed into various classifiers such as support vector machine (SVM), K-nearest neighbors (KNN), TreeBagger (TB), and dictionary learning (DL) classifiers in order to compare their performance. The proposed method was evaluated on three publicly available databases (NinaPro, CapgMyo (DB-a, DB-b and DB-c), CSL-HDEG) by performing intra-session, inter-session and inter-subject evaluations on each database. The experimental results indicated that the proposed method achieved the best accuracy (Acc) using DL, achieving Acc of 77.6% and 89.6% with CapgMyo DB-b and CSL-HDEMG databases, respectively, during inter-session evaluation, and 75.2%, 75.4%, 68.3%, and 67.7% with NinaPro, CapgMyo DB-b, CapgMyo DB-c, and CSL-HDEMG databases, respectively, during inter-subject evaluation. The proposed method performed better during both inter-session and inter-subject evaluations than the state-of-the-art methods.
In this Letter, a robust third‐order tensor decomposition of multi‐lead electrocardiogram (MECG) comprising of 12‐leads is proposed to reduce the dimension of the storage data. An order‐3 tensor structure is employed to represent the MECG data by rearranging the MECG information in three dimensions. The three‐dimensions of the formed tensor represent the number of leads, beats and samples of some fixed ECG duration. Dimension reduction of such an arrangement exploits correlations present among the successive beats (intra‐beat and inter‐beat) and across the leads (inter‐lead). The higher‐order singular value decomposition is used to decompose the tensor data. In addition, multiscale analysis has been added for effective care of ECG information. It grossly segments the ECG characteristic waves (P‐wave, QRS‐complex, ST‐segment and T‐wave etc.) into different sub‐bands. In the meantime, it separates high‐frequency noise components into lower‐order sub‐bands which helps in removing noise from the original data. For evaluation purposes, we have used the publicly available PTB diagnostic database. The proposed method outperforms the existing algorithms where compression ratio is under 10 for MECG data. Results show that the original MECG data volume can be reduced by more than 45 times with acceptable diagnostic distortion level.