Bertrand Décaudin

Prof. Bertrand Décaudin

Université de Lille
+1
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Antimicrobial Agents and Chemotherapy
Verified
Journal Article
Closed access
PDF file
MDMaryline Drouet
Maryline Drouet
FCFeng Chai
Feng Chai
CBChristine Barthélémy
Christine Barthélémy
GLGilles Lebuffe
Gilles Lebuffe
BDBertrand Debaene
Bertrand Debaene
POPascal Odou
Pascal Odou
Peripheral intravenous therapy is frequently used in routine hospital practice and, due to various factors, its most common side effect is phlebitis. The infusion of vancomycin is particularly associated with phlebitis despite its widespread use. French guidelines recommend central intravenous infusion for high concentrations of vancomycin, but peripheral intravenous therapy is often preferred in intensive care units. Methods of vancomycin infusion are either intermittent infusion or continuous infusion. A comparison of these methods underin vitroconditions simulating clinical use could result in better infusion efficacy. Human umbilical vein endothelial cells (HUVECs) were therefore challenged with clinical doses of vancomycin over a 24- to 72-h period using these infusion methods. Cell death was measured with the alamarBlue test. Concentration-dependent and time-dependent vancomycin toxicity on HUVECs was noted with a 50% lethal dose at 5 mg/ml after 24 h, reaching 2.5 mg/ml after 72 h of infusion, simulating long-term infusion. This toxicity does not seem to be induced by acidic pH. In comparing infusion methods, we observed that continuous infusion induced greater cell toxicity than intermittent infusion at doses higher than 1 g/day. The increasing use of vancomycin means that new guidelines are required to avoid phlebitis. If peripheral intravenous therapy is used to reduce infusion time, along with intermittent infusion, vein irritation and localized phlebitis may be reduced. Further studies have to be carried out to explore the causes of vancomycin endothelial toxicity.

1 April 2019 in Anaesthesia Critical Care & Pain Medicine
Verified
Journal Article
Closed access
MBMalik Benlabed
Malik Benlabed
MPMaxime Perez
Maxime Perez
RGRomain Gaudy
Romain Gaudy
SGStéphanie Genay
Stéphanie Genay
DLDamien Lannoy
Damien Lannoy
BDBertrand Décaudin
Bertrand Décaudin

16 May 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MPMaxime Perez
Maxime Perez
BDBertrand Décaudin
Bertrand Décaudin
WCWadih Abou Chahla
Wadih Abou Chahla
BNBrigitte Nelken
Brigitte Nelken
LSLaurent Storme
Laurent Storme
POPascal Odou
Pascal Odou
The large number of drugs administered simultaneously to neonates and children in hospital results in the formation of particles that are potentially infused. We have investigated the ability of IV in-line filters to eliminate particulate matter from multidrug infusion lines and so prevent contamination. The impact on particle occurrence of the internal volume of the IV line below the in-line filter was then evaluated. The multidrug therapy given to children was reproduced with and without in-line filtration. Three combinations with a filter were tested to vary the internal volume (V) between the filter and the catheter egress. The catheter was then connected to a dynamic particle count to evaluate the particulate matter potentially administered to children during infusion. The introduction of in-line filters led to a significant reduction in overall particulate matter, from 416,974 [208,479–880,229] to 7,551 [1,985–11,287] particles (p < 0.001). Larger particles of ≥10 and 25 µm were also significantly reduced. Adding an extension set to the egress of the in-line filter (V = 1.7 mL) caused a significant increase in particulate contamination for both. This study showed that in-line filtration is an effective tool in preventing particle administration to patients. Their position in the infusion in-line is therefore important because of its impact on internal volume and drug particle formation.

1 November 2021 in International Journal of Medical Informatics
Verified
Journal Article
Closed access
ECElodie Cuvelier
Elodie Cuvelier
LRLaurine Robert
Laurine Robert
EME. Musy
E. Musy
CRC. Rousselière
C. Rousselière
RMRomaric Marcilly
Romaric Marcilly
BDBertrand Décaudin
Bertrand Décaudin

1 January 2012 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
AFAurélie Foinard
Aurélie Foinard
BDBertrand Décaudin
Bertrand Décaudin
CBChristine Barthélémy
Christine Barthélémy
BDBertrand Debaene
Bertrand Debaene
POPascal Odou
Pascal Odou
Patients in intensive care units receive many drugs simultaneously but through limited venous accesses. Several intravenous therapies have to be administered through the same catheter, thus increasing the risk of physicochemical incompatibility. The purpose of this work was to assess and to quantify the impact of physical incompatibility on the mass flow rates of drugs infused simultaneously to the patient, through an in vitro study.

7 December 2012 in Annals of Occupational Hygiene
Verified
Journal Article
Open access
PDF file
TLThomas Queruau Lamerie
Thomas Queruau Lamerie
SNSusanne Nussbaumer
Susanne Nussbaumer
BDBertrand Décaudin
Bertrand Décaudin
SFSandrine Fleury-Souverain
Sandrine Fleury-Souverain
JGJean-François Goossens
Jean-François Goossens
POPascal Odou
Pascal Odou
The handling of antineoplastic agents results in chronic surface contamination that must be minimized and eliminated. This study was designed to assess the potential of several chemical solutions to decontaminate two types of work surfaces that were intentionally contaminated with antineoplastic drugs. A range of solutions with variable physicochemical properties such as their hydrophilic/hydrophobic balance, oxidizing power, desorption, and solubilization were tested: ultrapure water, isopropyl alcohol, acetone, sodium hypochlorite, and surfactants such as dishwashing liquid (DWL), sodium dodecyl sulfate (SDS), Tween 40, and Span 80. These solutions were tested on 10 antineoplastic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, irinotecan, cyclophosphamide, ifosfamide, doxorubicin, epirubicin, and vincristine. To simulate contaminated surfaces, these molecules (200ng) were deliberately spread onto two types of work surfaces: stainless steel and glass. Recovered by wiping with a specific aqueous solvent (acetonitrile/HCOOH; 20/0.1%) and an absorbent wipe (Whatman 903®), the residual contamination was quantified using high-performance liquid chromatography (HPLC) coupled to mass spectrometry. To compare all tested cleaning solutions, a performance value of effectiveness was determined from contamination residues of the 10 drugs. Sodium hypochlorite showed the highest overall effectiveness with 98% contamination removed. Ultrapure water, isopropyl alcohol/water, and acetone were less effective with effectiveness values of 76.8, 80.7, and 40.4%, respectively. Ultrapure water was effective on most hydrophilic molecules (97.1% for cytarabine), while on the other hand, isopropyl alcohol/water (70/30, vol/vol) was effective on the least hydrophilic ones (85.2% for doxorubicin and 87.8% for epirubicin). Acetone had little effect, whatever the type of molecule. Among products containing surfactants, DWL was found effective (91.5%), but its formulation was unknown. Formulations with single surfactant non-ionics (tween 40 and span 80) or anionic (SDS) were also tested. Finally, solutions containing 10–2 M anionic surfactants and 20% isopropyl alcohol had the highest global effectiveness at around 90%. More precisely, their efficacy was the highest (94.8%) for the most hydrophilic compounds such as cytarabine and around 80.0% for anthracyclines. Finally, the addition of isopropyl alcohol to surfactant solutions enhanced their decontamination efficiency on the least hydrophilic molecules. Measured values from the stainless steel surface were similar to those from the glass one. This study demonstrates that all decontamination agents reduce antineoplastic contamination on work surfaces, but none removes it totally. Although very effective, sodium hypochlorite cannot be used routinely on stainless steel surfaces. Solutions containing anionic surfactant such as SDS, with a high efficiency/safety ratio, proved most promising in terms of surface decontamination.