ROCIO ROMERO HERNANDEZ

Prof. Dr. ROCIO ROMERO HERNANDEZ

Seville University
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Journal of Building Engineering
Verified
Journal Article
Closed access
Eduardo Diz-MelladoEduardo Diz-Mellado
Eduardo Diz-Mellado
Emilio J. Mascort-AlbeaEmilio J. Mascort-Albea
Emilio J. Mascort-Albea
RHROCIO ROMERO HERNANDEZ
ROCIO ROMERO HERNANDEZ
Carmen Galan-MarinCarmen Galan-Marin
Carmen Galan-Marin
CRCarlos Rivera-Gómez
Carlos Rivera-Gómez
AJAntonio Jaramillo-Morilla
Antonio Jaramillo-Morilla

2 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ECElizabeth Contreras-Marín
Elizabeth Contreras-Marín
MAMaría Anguita-García
María Anguita-García
EAElia M Alonso-Guzman
Elia M Alonso-Guzman
AJAntonio Jaramillo-Morilla
Antonio Jaramillo-Morilla
Emilio J. Mascort-AlbeaEmilio J. Mascort-Albea
Emilio J. Mascort-Albea
CSCristina Soriano-Cuesta
Cristina Soriano-Cuesta
The use of industrial waste in civil engineering applications constitutes a potential innovative effort to reduce environmental degradation and enable a sustainable use of natural resources. This paper reports a comprehensive laboratory study that was performed to evaluate the rubber granulates from End-of-Life Tyres (ELTs) as a lightweight backfill material in retaining walls. Various tests have been performed to provide specific information on the mechanical and physical properties of a detailed range of particle sizes smaller than 12 mm, with six different particle size distributions (S1: 0.0–0.8 mm/S2: 0.6–2.0 mm/S3: 2.0–4.0 mm/S4: 2.0–7.0 mm/S5: 90% 2.0–7.0 mm + 10% 0.6–2.0 mm/S6: 50% 2.0–7.0 mm + 50% 0.6–2.0 mm). The density and unit weight, compaction energy, compressibility, shear strength, and deformability have been evaluated to determine their performance. As a main conclusion, the research confirms that rubber granulates from ELTs possess great potential as backfill material behind retaining walls. The characteristic values of the geotechnical parameters have been estimated according to Eurocode 7. The friction angle results range from 18.27 to 23.21 degrees, and the cohesion results are wide-ranging, with values from 9.35 to 17.83 kPa. For this reason, two cantilever L-shaped retaining walls, selected as representative case studies, have been tested with these sample properties. The results of the geotechnical verifications are presented together with a comparison of the safety factors in accordance with the Spanish standard design (CTE-DB-SE-C) and the European (EC7-1) regulations. The calculations indicate that the overdesign factors (ODF) achieved in the verifications using the material properties of the S4, S5, and S6 combination improve the calculation results obtained if a conventional filler material such as sand is considered.

1 December 2021 in Journal of Building Engineering
Verified
Journal Article
Open access
JMJuan Jesus Martin-Del-Rio
Juan Jesus Martin-Del-Rio
Jacinto CanivellJacinto Canivell
Jacinto Canivell
MARTA TORRES-GONZÁLEZMARTA TORRES-GONZÁLEZ
MARTA TORRES-GONZÁLEZ
Emilio J. Mascort-AlbeaEmilio J. Mascort-Albea
Emilio J. Mascort-Albea
RHROCIO ROMERO HERNANDEZ
ROCIO ROMERO HERNANDEZ
FAF.J. Alejandre-Sánchez
F.J. Alejandre-Sánchez

3 January 2025 in Geotechnical and Geological Engineering
Verified
Journal Article
Closed access
PDF file
Maziyar BahriMaziyar Bahri
Maziyar Bahri
RHROCIO ROMERO HERNANDEZ
ROCIO ROMERO HERNANDEZ
Emilio J. Mascort-AlbeaEmilio J. Mascort-Albea
Emilio J. Mascort-Albea
CSCristina Soriano-Cuesta
Cristina Soriano-Cuesta
AJAntonio Jaramillo-Morilla
Antonio Jaramillo-Morilla

2 February 2023 in Building Research & Information
Verified
Journal Article
Closed access
Francisco M. Hidalgo-SánchezFrancisco M. Hidalgo-Sánchez
Francisco M. Hidalgo-Sánchez
MARTA TORRES-GONZÁLEZMARTA TORRES-GONZÁLEZ
MARTA TORRES-GONZÁLEZ
Emilio J. Mascort-AlbeaEmilio J. Mascort-Albea
Emilio J. Mascort-Albea
Jacinto CanivellJacinto Canivell
Jacinto Canivell
RHROCIO ROMERO HERNANDEZ
ROCIO ROMERO HERNANDEZ
JMJuan Jesus Martin-Del-Rio
Juan Jesus Martin-Del-Rio
Non-destructive testing (NDT) for the diagnosis of heritage buildings has proved to be one of the most sustainable approaches in the field of preventive conservation. Nevertheless, the comprehensive management of NDT information is complex, often resulting in a poorly optimized use of the data. This contribution aims to propose a method for integrating NDT data in a standardized way into simplified digital information models, produced using Geographic Information Systems (GIS). This method is applied to the plasterwork located in the Courtyard of the Maidens, which are elements with an enormous historic-artistic value in the Royal Alcazar of Seville (Spain), a significant UNESCO monument. For this purpose, a multi-scale web GIS-based model has integrated the NDT information from the plasterworks, such as ambient conditions, damage mapping, C-Shore Hardness, Superficial Humidity, Infrared thermography (IRT), Digital Image Processing (DIP) and Ground Penetration Radar (GPR). The combined georeferencing of the data from the various measurements and their simultaneous visualization has enabled the detection of vulnerable areas in the complex. The results are easily accessible for managers, and additionally show the analytical potential of the research approach, thereby allowing a quick diagnosis and hierarchization of tasks.

18 June 2022 in Symmetry
Verified
Journal Article
Open access
PDF file
Maziyar BahriMaziyar Bahri
Maziyar Bahri
Emilio J. Mascort-AlbeaEmilio J. Mascort-Albea
Emilio J. Mascort-Albea
RHROCIO ROMERO HERNANDEZ
ROCIO ROMERO HERNANDEZ
MKMohammadreza Koopialipoor
Mohammadreza Koopialipoor
CSCristina Soriano-Cuesta
Cristina Soriano-Cuesta
AJAntonio Jaramillo-Morilla
Antonio Jaramillo-Morilla
In order to solve connectivity problems in metropolitan areas, the development of underground metro lines constitutes an unquestionable requirement. However, the construction work thereof encounters unfavourable circumstances when surface excavations must be carried out that cross historical areas of the city, due to the need to control surface movements. The design of the metro in the city of Seville (Spain) from 2004 to 2006 provides a representative example of this situation and triggered major upheavals that exerted repercussions on historical buildings. For these reasons, the excavation stages of Line 1 of this metro have been simulated by numerical methods using FLAC3D software and validated with the results provided by the real conditions. Consequently, various surface settlements have been evaluated by taking not only variates of the main parameters that characterise the soil of Seville, but also of the various load situations and excavation conditions. Notable results have been achieved through calibration of 54 variants of the same model corresponding to Line 1, and their comparison with the real results obtained in nine critical areas of the itinerary. The results obtained have made it possible to determine the effects of excavation on the subsoil of the city of Seville with great accuracy, since the percentage error of calculated vertical surface movements varies from 0.1% to 5.3%.